- All
- Favorite
- Popular
- Most rated
| Brand | JIAYUAN |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | NANO-200 |
| Price | USD 6,750 (FOB Beijing) |
| Sample Volume | 0.5–2 µL |
| Optical Pathlengths | 0.2 mm & 1.0 mm |
| Light Source | Xenon Flash Lamp (>10⁹ flashes) |
| Wavelengths | Fixed at 230 nm, 260 nm, 280 nm |
| Absorbance Accuracy | ±1% |
| Absorbance Precision | ±0.003 Abs |
| Absorbance Range | 0.02–80 (equivalent to 10 mm pathlength) |
| dsDNA Quantitation Range | 10–4000 ng/µL |
| Protein Quantitation Range | 0.1–100 mg/mL |
| Measurement Time | ≤5 s |
| Dimensions | 210 × 268 × 181 mm (W×D×H) |
| Sample Stage Material | Fused Silica Fiber + Hard-Anodized Aluminum |
| Power Supply | 24 V DC |
| Power Consumption | 40 W |
| Brand | ZEEDO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TH-701 |
| Price | USD 4,950 (FOB Beijing) |
| Construction Material | 304 Stainless Steel (1.2 mm thickness) |
| Dimensions (L×W×H) | 1500 × 800 × 1900 mm |
| Net Weight | 215 kg |
| Exhaust Airflow | ≥1600 m³/h |
| Work Surface Incline | ≥7° |
| Water Supply System | Dual-temperature (hot/cold), PPR piping, articulating metal hose faucet |
| Drainage | PE corrosion-resistant piping with integrated stainless steel filter basket |
| Ventilation Configuration | Waist-level negative-pressure suction or optional under-bench downdraft system |
| Lighting | High-lumen LED task illumination |
| Optional Accessories | HD digital imaging module with 1080p display, touchless hand dryer, ANSI-compliant wall-mounted eyewash station, integrated tissue shredder unit |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY92-IIDN |
| Ultrasonic Frequency | 20–25 kHz (auto-frequency tracking) |
| Output Power | 900 W (touch-key continuous adjustment) |
| Pulse Mode | On-time 0.1–99.9 s / Off-time 0.1–99.9 s / Total Duration 0.1–99 min |
| Duty Cycle | 0.1–99.9% |
| Temperature Monitoring Range | 0–100 °C |
| Standard Probe Diameter | Φ6 mm |
| Optional Probes | Φ2, Φ3, Φ8, Φ10, Φ15 mm |
| Sample Volume Capacity | 0.2–600 mL |
| Input Voltage | 220/110 V, 50/60 Hz |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 3H24RI |
| Max Speed | 24,000 rpm |
| Max RCF | 39,900 × g |
| Max Capacity | 4 × 100 mL |
| Dimensions (L×W×H) | 710 × 630 × 350 mm |
| Temperature Range | −20 °C to +40 °C |
| Temp Control Accuracy | ±1 °C |
| Acceleration/Deceleration | 10 selectable rates |
| Noise Level | ≤65 dB(A) |
| Power Supply | 220 V AC, 50 Hz |
| Total Power | 1.5 kW |
| Weight | 75 kg |
| Refrigerant | R404a (non-CFC) |
| Display | TFT true-color touch LCD |
| Programmable Protocols | >100 user-defined methods |
| Safety Certifications | CE-compliant design per IEC 61010-2-020, ISO 13485-aligned manufacturing processes |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Microscope Type | Upright Biological Microscope |
| Model | E200 |
| Optical System | CFI60 Infinity-Corrected |
| Magnification Range | 40×–1000× |
| Eyepiece Tube | E2-TB Binocular (hinged, 30° inclination) or E2-TF Trinocular (30° inclination, 360° rotation, interpupillary distance 47–75 mm) |
| Eyepieces | CFI E10×/20 mm (field number 20 mm), optional CFI 15×/12 mm |
| Objectives | CFI E Plan Achromat 4× (NA 0.10), 10× (NA 0.25), 40× (NA 0.65), 100× oil (NA 1.25) |
| Nosepiece | Internal quadruple revolving nosepiece |
| Stage | Rectangular mechanical stage (216 × 150 mm), X–Y travel 78 × 54 mm, low-position coaxial controls, auto-return focusing mechanism |
| Condenser | E2 Abbe condenser (NA 1.25) with iris diaphragm and objective position markers |
| Illumination | 6 V / 20 W halogen lamp, centerable and height-adjustable |
| Focus Mechanism | Coarse focus (37.7 mm per revolution), fine focus (0.2 mm per revolution, 2 µm graduation), adjustable coarse torque, built-in stage stop for high-magnification protection |
| Compliance | Designed for ISO 10993-5 biocompatibility of user-contact components |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | FE30K |
| Form Factor | Benchtop |
| Conductivity Range | 0.1 μS/cm to 199.9 mS/cm |
| TDS Range | 0.1 mg/L to 199.9 g/L |
| Resistivity Range | 0.1 Ω·m to 19.99 MΩ·cm |
| Salinity Range | 0.00 to 19.99 psu |
| Temperature Range | 0.0 to 100.0 °C |
| Conductivity Accuracy | ±0.5% of reading |
| Temperature Accuracy | ±0.1 °C |
| Temperature Compensation | Linear, adjustable from 0.000 to 10.000 %/°C |
| reference temperatures | 20 °C and 25 °C |
| Calibration | Single-point with three pre-stored standard solutions (84 μS/cm, 1413 μS/cm, 12.88 mS/cm) |
| Display | Backlit LCD showing conductivity/TDS/salinity/resistivity, temperature, stability indicator, calibration status, and compensation settings |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | ES-300 |
| Quotation | Upon Request |
| Wax Bath Temperature Range | Ambient to 99 °C |
| Cold Plate Temperature Range | Ambient to −20 °C |
| Wax Bath Capacity | 3.2 L |
| Operating Ambient Temperature | 0–45 °C |
| Net Weight | 40 kg |
| Embedding Unit Dimensions (W×D×H) | 560 × 540 × 375 mm |
| Cold Plate Dimensions (W×D×H) | 345 × 600 × 375 mm |
| Voltage/Power | 220 V, 50 Hz / 800 W |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | M80 |
| Zoom Ratio | 8:1 |
| Magnification Range | 7.5×–60× (with 1× objective and 10× eyepieces) |
| Resolution | 309 lp/mm (at 60×, 1× objective) |
| Working Distance | 83.4 mm (with Plan Apochromat 1× objective) |
| Field of View | Ø98 mm (max, dependent on optical configuration) |
| LED Illumination | 6500 K color temperature, 50,000 h lifetime, fanless thermal management |
| Optical Design | Parallel optical path (Common Main Objective, CMO), multi-coated optics, lead-free housing |
| Electrostatic Dissipation | Surface resistivity 2×10¹¹ Ω/mm², discharge time <2 s (1000 V → 100 V) |
| Modular Interface | 8-position zoom detent slots for repeatable magnification settings |
| Objective Options | Achromatic (0.32×–2.0×), Plan Apochromat (0.8×–1.6×) |
| Eyepiece Options | Widefield 10×, 16×, 25×, 40× with adjustable eye cups and interpupillary distance |
| Ergonomic Modules | ErgoTube® and ErgoModules® with tilt angle 10°–50° |
| Software Compatibility | Leica Application Suite (LAS) |
| Origin | Jiangsu, China |
|---|---|
| Cabinet Type | Class II, Type B2 (Total Exhaust) |
| External Dimensions (L×W×H) | 1500 × 790 × 2050 mm |
| Internal Work Area (L×W×H) | 1300 × 600 × 620 mm |
| Filter Efficiency | HEPA ≥99.995% @ 0.3 µm |
| Downflow Velocity | 0.35 m/s |
| Inflow Velocity | 0.35 m/s |
| Noise Level | ≤58 dB(A) |
| Power Supply | AC 220 V, 1Φ, 50 Hz |
| Max. Rated Power | 2.1 kVA |
| Weight | 300 kg |
| Lighting | 36 W × 2 fluorescent lamps |
| UV Lamp | 20 W × 1 |
| Illuminance | ≥800 lx |
| Biological Protection Performance | ≤10 CFU/plate (impact sampler), ≤5 CFU/plate (slit sampler) |
| Product Protection | ≤5 CFU/plate |
| Cross-contamination Protection | ≤2 CFU/plate |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DHG-9076A |
| Power Supply | 220 V / 50 Hz |
| Temperature Range | RT +10 °C to 250 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Chamber Volume | 76 L |
| Internal Dimensions (W×D×H) | 450 × 400 × 450 mm |
| External Dimensions (W×D×H) | 740 × 618 × 630 mm |
| Standard Shelving | 3 adjustable stainless steel trays |
| Timer Range | 1–9999 minutes |
| Operating Ambient Temperature | +5 to +40 °C |
| Input Power | 2050 W |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | DD5M |
| Maximum Capacity | 4 × 500 mL |
| Maximum Speed | 4000 rpm |
| Dimensions (L×W×H) | 586 × 644 × 370 mm |
| Centrifugation Class | Biological Macromolecules |
| Noise Level | ≤65 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Total Power | 1000 W |
| Weight | 75 kg |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SW-CJ-2FD |
| Instrument Category | Vertical Flow Clean Bench |
| Cleanliness Class | ISO 5 (Class 100 per US Federal Standard 209E) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Dual-Operator, Single-Face Configuration |
| Airflow Pattern | Vertical Unidirectional Laminar Flow |
| Work Surface Material | Electropolished Stainless Steel (304) |
| Cabinet Construction | Powder-Coated Steel |
| Average Air Velocity | ≥0.3 m/s (adjustable via dual-speed touch-control fan system) |
| Illumination | ≥300 lx (14 W fluorescent ×2) |
| UV Sterilization | 8 W germicidal lamp ×2 (interlocked with lighting and safety door switch) |
| Microbial Contamination | ≤0.5 CFU/plate (90 mm Petri dish, 4-hour exposure) |
| Power Supply | 220 V AC / 50 Hz |
| Input Power | 500 VA |
| Net Weight | 170 kg |
| Working Area Dimensions (W×D×H) | 1360 × 690 × 520 mm |
| Overall Dimensions (W×D×H) | 1500 × 730 × 1600 mm |
| HEPA Filter Specification | 610 × 610 × 50 mm ×2 (≥99.995% @ 0.3 µm) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | DMLP |
| Optical System | Infinity-Corrected |
| Illumination | 12 V / 100 W Halogen (Transmitted & Reflected) |
| Eyepiece | 10×, FOV 22–25 mm |
| Observation Modes | Brightfield, Polarized Light, Optional DIC |
| Objective Turret | 5-Position, Centerable |
| Polarization Components | Rotatable Polarizer & Analyzer, Bertrand Lens, Conoscopic Viewing, λ/4 & λ/2 Retardation Plates, Adjustable Wedge Compensator |
| Objective Compatibility | Plan Achromat, Plan Semi-Apochromat, and Plan Apochromat Polarizing Objectives |
| Tube Configuration | Trinocular (Simultaneous Visual Observation & Imaging) |
| Software Compatibility | Leica Application Suite (LAS), Third-Party Image Analysis Platforms |
| Compliance | Designed for ISO 9001–certified manufacturing |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DZ2000 |
| Price | USD 2,650 (FOB) |
| Optical System | UCIS Infinity-Corrected, Parfocal, Positive-Image Path |
| Magnification Range | 40×–400× (expandable to 960× with optional 60× objective) |
| Eyepieces | Widefield PL10×/20 mm (high-eye-point, reticle-compatible) |
| Objectives | Infinity Long Working Distance (LWD) Plan Achromatic: 4×, 10×, 20×, 40× |
| Phase Contrast | 10×, 20×, 40× LWD |
| Condenser | N.A. 0.70, WD 72 mm / 120 mm, removable, with aperture diaphragm |
| Focusing | Coaxial coarse/fine focus |
| Stage | Mechanical XY stage, 80 × 50 mm travel |
| Illumination | 6 V / 30 W halogen lamp with aspheric collector lens |
| Fluorescence Module | Rotating filter turret for dual-band (B/G) or quad-band (UV/V/B/G) excitation |
| Camera Port | Trinocular port with 80:20 beam splitter ratio |
| Compliance | Designed per ISO 10934-1 (Microscopes — Nomenclature of components), IEC 61010-1 (Safety requirements for electrical equipment), and GLP-aligned documentation architecture |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | EC3 |
| Sensor Resolution | 3.1 MP (Color CMOS) |
| Frame Rate | Up to 15 fps (progressive scan) |
| Interface | USB 2.0 |
| Mount | C-mount |
| Software Compatibility | Leica Application Suite (LAS) X, Windows/macOS |
| Target Use | Educational microscopy, routine light microscopy documentation |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | KD-202A |
| Price | USD 1,780 (FOB Zhejiang) |
| Cutting Thickness Range | 1–25 µm (continuous), >25 µm (step-adjustable) |
| Minimum Graduation | 1 µm |
| Max Specimen Area (Paraffin) | 40 × 30 mm |
| Thickness Accuracy | ±10% |
| Blade Holder Adjustment | Horizontal & Anterior–Posterior Translation |
| Dimensions (W×D×H) | 380 × 340 × 270 mm |
| Net Weight | 21.5 kg |
| Brand | TECAN |
|---|---|
| Origin | Switzerland |
| Model | HydroFlex |
| Instrument Type | Multifunctional Microplate Washer |
| Wash Head Configuration | 8-channel or dual 8-channel (16-channel equivalent) |
| Wash Fluid Channels | 1, 2, or 4 selectable |
| Soaking Time | Programmable |
| Wash Cycles | 1–10 |
| Residual Volume per Well | ≤1.8 µL |
| Orbital Shaking | Linear, 3 adjustable speeds |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | RM2125 RTS |
| Cutting Thickness Range | 0.5–100 µm |
| Sectioning Mode | Manual Rotary |
| Specimen Stage Travel | 24 mm (horizontal), 30 mm (vertical) |
| Knife Holder | Standard H-type (compatible with disposable and reusable steel knives) |
| Footswitch Optional | Yes |
| Safety Features | Blade guard, ergonomic handwheel lock, specimen clamp with dual-lock mechanism |
| Compliance | CE-marked, conforms to IEC 61010-1 for laboratory equipment safety |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FD-1C |
| Price | USD 4,500 (FOB Beijing) |
| Condenser Temperature (No Load) | ≤ −50 °C (−80 °C optional) |
| Ultimate Vacuum (No Load) | < 13 Pa |
| Shelf Area | 0.08 m² (3 stainless steel shelves, Φ200 mm each) |
| Chamber Dimensions | Φ320 × 550 mm |
| Max Sample Volume | 900 mL (at 10 mm thickness) or 192 × 22 mm vials |
| Lyophilization Cycle Time | ~24 h (for ≤10 mm layer thickness) |
| Standard Vacuum Pump | 2 L/min domestic rotary vane pump |
| Optional Vacuum Pump | Certified oil-sealed or dry scroll pump (ISO 8573-1 Class 0 compliant) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | M50 |
| Zoom Ratio | 5:1 |
| Magnification Range (with standard optics) | 6.3×–40× |
| Max. Total Magnification | 320× |
| Objective Types | Achromatic (0.32×–2.0×), Plan Achromatic (0.8×–1.6×) |
| Working Distance Range | 27.4 mm – 303 mm |
| Field of View Diameter | 5.75 mm – 116.8 mm |
| Resolution (at 40×) | 225 lp/mm |
| Numerical Aperture (1× objective) | 0.15 |
| Ergonomic Viewing Angle | 10°–50° |
| ESD Compliance | Surface Resistivity 2×10¹¹ Ω/mm², Discharge Time <2 s (1000 V → 100 V) |
| Optical Design | Common Main Objective (CMO), Parallel Light Path |
| Coating | Multi-layer anti-reflective coatings |
| Eyepieces | Wide-field 10×, 16×, 25×, 40× with adjustable eyecups and click-stop positioning |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | DM2500P |
| Optical Configuration | Transmitted & Reflected Light |
| Illumination | 12 V / 100 W Halogen |
| Focus System | Dual-Height-Adjustable Manual Coarse/Fine Focus |
| Objective Turret | 5-position, Centerable |
| Field of View | 25 mm |
| Observation Modes | Brightfield, Darkfield, Phase Contrast, DIC, Fluorescence (reflected), Orthogonal Polarization, Conoscopy |
| Polarization System | Standard or Advanced Bertrand Lens Module with Centering & Focusing Adjustment |
| Condenser | Manual or CDA-assisted, Polarization-optimized |
| Stage Options | 45°-click Rotation Stage, Optional Heating Stage |
| Objective Types Supported | Achromatic, Plan-Achromatic, Plan-Fluor, Oil Immersion |
| Software Compatibility | Leica Application Suite (LAS) X with Image Acquisition, Measurement & Analysis Modules |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | DS |
|---|---|
| Origin | Beijing, China |
| Model | DMT-2500 |
| Speed Range | 500–2500 rpm |
| Speed Accuracy | ±50 rpm (at 2500 rpm) |
| Oscillation Mode | Rotary |
| Amplitude | 4 mm |
| Timing Range | 1 s – 9999 min |
| Maximum Load Capacity | 5 kg |
| Top Plate Dimensions | 311 × 184 mm |
| Instrument Dimensions (W×D×H) | 426 × 250 × 480 mm |
| Net Weight | 21.5 kg |
| Power Supply | 100–230 V, 50/60 Hz |
| Power Consumption | 60 W |
| Housing Material | ABS Plastic |
| Display | LED, showing speed and time |
| Operating Modes | Touch-Start (pulse) and programmable timer |
| Standard Accessories | 12 mm foam tube rack + tray pad |
| Optional Racks | DMT-A (Ø10 mm, 50-well), DMT-B (Ø12 mm, 50-well), DMT-C (Ø13 mm, 50-well), DMT-D (Ø16 mm, 50-well, compatible with 15 mL centrifuge tubes), DMT-E (Ø25 mm, 15-well), DMT-F (Ø29 mm, 15-well, compatible with 50 mL centrifuge tubes), DMT-H (replaceable upper & lower tray pads, 305 × 178.5 × 25 mm) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ZK-96 |
| Price Range | USD 28,000 – 42,500 |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automated Platform |
| Throughput | 1–96 Samples per Run |
| Sample Volume Range | 30 µL – 1000 µL |
| Processing Time per Batch | 20–60 min |
| Magnetic Bead Recovery Efficiency | >98% |
| Heating Temperature Range (Lysis/Elution) | Ambient to 110 °C |
| Oscillation | Multi-Speed & Multi-Amplitude Programmable |
| Air Filtration | Dual HEPA + UV-C Sterilization |
| Control Interface | 7-inch Capacitive Touchscreen (Chinese UI) |
| Connectivity | Wi-Fi Enabled |
| Remote Monitoring | Mobile App Supported |
| Dimensions (W×D×H) | 780 × 440 × 500 mm |
| Weight | 42 kg |
| Power Supply | AC 110–220 V, 50/60 Hz |
| Operating Environment | 10–40 °C, <80% RH (non-condensing) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Product Category | Domestic |
| Model | HYG-A |
| Price | USD 3,500 (approx.) |
| Instrument Type | Air-Bath Constant-Temperature Orbital Shaker |
| Timer Range | 0–999 min |
| Oscillation Frequency | 40–280 rpm |
| Orbit Diameter | 26 mm |
| Temperature Range | 5°C to 60°C (at ambient 25°C) |
| Temperature Accuracy | ±0.1°C |
| Temperature Uniformity | ±0.5°C |
| Shelf Count | 2-tier |
| Tray Dimensions | 710 × 450 mm |
| Capacity per Shelf | 15 × 1000 mL or 24 × 500 mL or 35 × 250 mL Erlenmeyer flasks |
| Display | LED digital |
| Input Power | 1200 W |
| Overall Dimensions (W×D×H) | 900 × 750 × 1530 mm |
| Net Weight | 180 kg |
| Power Supply | 220 V, 50 Hz |
| Interior Lighting | 20 W |