OK-HQ Series Air-Exchange Thermal Aging Test Chamber for Calibration and Verification of Environmental Test Equipment
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,600 (Reference Only) |
| Temperature Range | RT+10°C to 200°C / 300°C |
| Temperature Uniformity | ±2°C |
| Temperature Stability | ±0.5°C |
| Air Exchange Rate | 2–100 cycles/hour |
| Adjustable Air Exchange Time | 1 min – 99 h |
| Chamber Volume Options | 100 L – 800 L |
| Power Consumption | 4.0–9.0 kW |
| Compliance | ASTM D5423-09 (Type II), ASTM D5374-93 (2005), UL 1581, GB/T 2423.2, IEC 60068-2-2, JIS C 60068-2-2, VDE 0470 |
Overview
The OK-HQ Series Air-Exchange Thermal Aging Test Chamber is a precision-engineered calibration reference instrument designed for metrological verification and performance validation of industrial thermal aging chambers used in quality control and R&D laboratories. Unlike standard aging ovens, this chamber integrates traceable air exchange rate measurement capability—enabling direct calibration of airflow dynamics critical to polymer, wire & cable, elastomer, and textile material aging protocols. It operates on forced-convection thermoregulation with horizontal airflow distribution, conforming to the fundamental principles of ISO/IEC 17025-compliant environmental test equipment verification. Its dual-purpose architecture supports both routine chamber qualification (e.g., temperature mapping, air exchange rate validation per ASTM D5423 Annex A3) and as a primary reference standard for accredited calibration laboratories performing ISO/IEC 17025 scope assessments under Clause 6.4.
Key Features
- Precision air-exchange regulation system with digitally adjustable cycle count (2–100/h) and time resolution down to 1 minute—fully compliant with ASTM D5423-09 Type II oven specifications.
- Microprocessor-based PID + SSR temperature controller with 0.1°C setpoint and display resolution, integrated timer (1–9999 min), and real-time deviation logging.
- Horizontal forced-air circulation system featuring high-temperature-rated centrifugal blower and symmetrical baffle-guided airflow—ensuring ≤±2°C spatial uniformity across full working volume (validated per IEC 60068-3-5).
- Double-wall construction: inner chamber of polished SUS304 stainless steel (electropolished finish); outer shell of A3 cold-rolled steel with epoxy powder coating; insulation via 100 mm thick ultra-fine glass fiber.
- Calibration-ready interface: 50 mm diameter feedthrough port (left side), optional RTD sensor mounting flange, and standardized 250–700 mm rotating turntable (diameter model-dependent) for uniform sample exposure.
- Safety architecture includes independent over-temperature cut-off, motor thermal overload protection, earth leakage detection, and short-circuit interruption—all certified to IEC 61000-6-2/6-4 EMC standards.
Sample Compatibility & Compliance
The OK-HQ chamber accommodates standardized test specimens per ASTM D5423, UL 1581 Section 1060 (wire insulation aging), IEC 60811-501 (polymeric cable compounds), and GB/T 2951.12 (Chinese national standard for electric cable testing). Its validated air exchange profile meets the mandatory ventilation requirements for Type II laboratory ovens specified in ASTM D5423-09, ensuring reproducible oxidative degradation kinetics in thermally sensitive materials. All models undergo factory temperature mapping per ISO/IEC 17025 Annex A.2 and are supplied with a Certificate of Conformance referencing NIST-traceable calibration data for chamber temperature sensors and airflow transducers. The system supports GLP/GMP-aligned operation when paired with optional audit-trail-enabled software (see Software & Data Management).
Software & Data Management
While the base unit features LED digital control, optional PC-based software (OK-DataLink v3.2) enables full compliance with FDA 21 CFR Part 11 and EU Annex 11 requirements. This application provides electronic signature support, user-access-level management (admin/operator/auditor), automatic generation of IQ/OQ documentation templates, and timestamped export of temperature stability logs, air exchange cycle records, and deviation alerts. All data files are stored in non-proprietary CSV/CSVX format with SHA-256 hash integrity verification. Raw sensor outputs (Pt100 RTDs, hot-wire anemometers) are logged at 1 Hz sampling rate and archived with metadata including operator ID, chamber ID, and environmental ambient conditions.
Applications
- Calibration and periodic verification of production-line aging ovens in wire & cable manufacturing facilities (per UL 1581 Clause 1060.5).
- Validation of thermal aging test methods for automotive elastomers (SAE J2236), aerospace sealants (AMS 3675), and medical device polymers (ISO 10993-12).
- Supporting ISO/IEC 17025 accreditation audits for laboratories performing environmental test equipment calibration (ILAC-G8:2022).
- Research into oxidation kinetics of polyolefins, PVC stabilizers, and silicone rubbers under controlled ventilation conditions.
- Temperature uniformity mapping (per IEC 60068-3-5) and air exchange rate certification (per ASTM D5423 Annex A3) for internal QA/QC departments.
FAQ
Is this chamber suitable for direct calibration of third-party aging ovens?
Yes—the OK-HQ series is explicitly designed as a metrological reference instrument with documented measurement uncertainty (k=2) for temperature (±0.3°C) and air exchange rate (±3% of reading), meeting ISO/IEC 17025 Clause 6.4.3 requirements.
Does it include NIST-traceable calibration documentation?
All units ship with a Factory Calibration Certificate referencing NIST SRM 1750a (thermistor) and NIST SRM 2010 (anemometer calibrator), valid for 12 months from date of shipment.
Can the chamber be integrated into a LabVantage or Thermo Fisher SampleManager LIMS?
Yes—via OPC UA protocol support in OK-DataLink v3.2, enabling bidirectional data exchange with major LIMS platforms for automated report generation and audit trail synchronization.
What maintenance intervals are recommended for long-term accuracy?
Annual recalibration of temperature sensors and airflow transducers is advised; quarterly verification of door seal integrity and baffle alignment per manufacturer’s Maintenance Protocol MP-OKHQ-01.
Are custom chamber dimensions or extended temperature ranges available?
Custom engineering is supported for OEM integration—contact technical sales for feasibility assessment of RT+10°C to 400°C variants, inert gas purge options, or Class I Div 2 hazardous area configurations.