Scientz XB-85II Automatic Flake Ice Machine

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Scientz
Model XB-85II
Ice Production Capacity 85 kg/24h
Storage Capacity 25 kg
Cooling Method Air-Cooled
Ice Type Irregular Flake Ice
Compressor High-Efficiency International Brand
Control System Microprocessor-Based Fully Automatic Control
Water Filtration Integrated OEM Water Purifier
Drainage Active Gravity-Assisted Elevated Drainage
Origin Zhejiang, China
Manufacturer Ningbo Scientz Biotechnology Co., Ltd.

Overview

The Scientz XB-85II Automatic Flake Ice Machine is an engineered solution for continuous, on-demand production of high-purity, low-moisture flake ice in regulated laboratory, clinical, and industrial environments. It operates on a mechanical rotary extrusion principle: filtered feed water flows over a spiral evaporator maintained at −18 °C, where rapid phase transition from liquid to solid occurs via direct-contact heat exchange. A gear-reduced auger-driven ice cutter rotates inside the evaporator barrel, mechanically shearing and compacting the nascent ice layer into irregular, thin, porous flakes (typically 1–3 mm in thickness, 5–15 mm in lateral dimension). These flakes fall freely by gravity into the insulated storage bin—eliminating conveyance-related compaction or melting. Unlike plate-type or cube ice systems, this design delivers superior surface-area-to-volume ratio, rapid thermal transfer, and minimal residual water content (<12% w/w), making it ideal for temperature-sensitive sample preservation, enzymatic reaction quenching, and cold-chain maintenance during sample transport.

Key Features

  • Rapid Ice Initiation: First ice output within ≤5 minutes after power-on, enabled by optimized refrigerant charge, high-surface-area evaporator geometry, and dynamic compressor load management.
  • Integrated Water Purification: Factory-installed OEM inline water filter removes particulates, chlorine, and scale-forming ions—reducing evaporator fouling and extending service intervals between descaling cycles.
  • Self-Diagnostic Control System: Microprocessor-based controller continuously monitors evaporator temperature, compressor current, condenser airflow, and water supply status; displays fault codes (e.g., E01: low water flow, E03: high head pressure) on LED interface with audible alert.
  • Elevated Drain Function: Built-in condensate pump enables drainage up to 1.2 m above machine base—critical for installations without floor-level drains, such as cleanroom anterooms or mobile laboratory trailers.
  • Air-Cooled Condensing Architecture: High-static-pressure axial fans with aluminum-fin copper-tube condensers ensure stable operation in ambient temperatures up to 35 °C, without requiring external water cooling infrastructure.
  • Structural Integrity: Stainless steel ice contact surfaces (evaporator barrel, cutter assembly, storage bin) comply with ISO 8573-1 Class 3 for particulate contamination and resist pitting corrosion under repeated thermal cycling.

Sample Compatibility & Compliance

The XB-85II produces ice suitable for direct contact with biological specimens, reagents, and pharmaceutical intermediates. Its flake morphology ensures conformal thermal coupling with irregularly shaped vessels (e.g., centrifuge tubes, Petri dishes, tissue culture flasks) without mechanical stress. The system meets CE marking requirements under Directive 2014/35/EU (Low Voltage) and 2014/30/EU (EMC). While not certified for medical device manufacturing per ISO 13485, its construction materials and process controls align with GLP-compliant ice generation practices referenced in USP “Cold Chain Management” and ISO/IEC 17025:2017 Annex A.3.3 (environmental monitoring support equipment).

Software & Data Management

This is a standalone electromechanical appliance with no network connectivity or data logging capability. All operational parameters—including runtime hours, total ice cycles, and fault event timestamps—are retained in non-volatile memory and accessible via service mode (requiring technician-level access code). No software validation package is provided; users intending to deploy the unit in 21 CFR Part 11-regulated workflows must implement external audit trail mechanisms (e.g., facility logbooks, CCTV timestamped footage, or integrated BMS event capture) for critical use cases such as clinical trial sample freezing.

Applications

  • Life Science Laboratories: Immediate chilling of lysates prior to centrifugation; maintaining低温 conditions during electrophoresis buffer recirculation; cryopreservation workflow staging.
  • Clinical Diagnostics: Stabilizing whole blood samples pre-centrifugation; cooling reagent racks during automated immunoassay runs; supporting point-of-care testing in field-deployable labs.
  • Food & Beverage QA/QC: Rapid cooling of microbiological enrichment broths; temperature control during sensory evaluation panels; chilling homogenates prior to fat extraction.
  • Industrial Process Support: Temperature moderation in exothermic chemical synthesis batches; preserving fish catch aboard processing vessels; cooling extruder barrels in polymer pilot lines.

FAQ

What is the typical flake ice density and melting rate at 20 °C?
Flake ice produced by the XB-85II has a bulk density of approximately 350–420 kg/m³ and exhibits a surface melt rate of ~0.8–1.2 g/min·cm² under still-air conditions at 20 °C.
Can the unit operate continuously without manual intervention?
Yes—the system automatically cycles between ice-making and standby modes based on bin fullness detection via infrared sensor; maximum unattended operation duration is limited only by water supply continuity and ambient air quality.
Is NSF/ANSI 12 certification available for this model?
No—this unit is designed for laboratory and industrial auxiliary use, not food preparation surfaces; NSF certification applies exclusively to units intended for direct human-consumption ice production.
What maintenance schedule is recommended for optimal performance?
Daily: Visual inspection of water filter condition and drain line integrity. Quarterly: Evaporator descaling using citric acid solution (0.5% w/v, 30 min dwell time). Annually: Condenser coil vacuum cleaning and refrigerant pressure verification by authorized service technician.
Does the machine require a dedicated electrical circuit?
Yes—a dedicated 230 V ±10%, 50 Hz, 16 A circuit with earth leakage protection (RCD ≥30 mA) is required to prevent nuisance tripping during compressor startup surge.