SAIL HERO XHN2000B Chemiluminescence NO/NO₂/NOₓ Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand SAIL HERO
Origin Hebei, China
Manufacturer Type Original Equipment Manufacturer (OEM)
Country of Manufacture China
Model XHN2000B
Detection Principle Gas-Phase Chemiluminescence
Measured Species NO, NO₂ (via catalytic conversion), NOₓ (sum)
Compliance Certified by China Environmental Monitoring Instrument Quality Supervision & Inspection Center

Overview

The SAIL HERO XHN2000B is a high-stability, laboratory-grade chemiluminescence analyzer engineered for continuous, real-time quantification of nitric oxide (NO), nitrogen dioxide (NO₂), and total reactive nitrogen oxides (NOₓ) in ambient air and stack emission streams. It operates on the well-established gas-phase chemiluminescence principle: NO reacts stoichiometrically with ozone (O₃) to form electronically excited NO₂*, which emits photons at characteristic wavelengths (600–3000 nm) upon relaxation. The intensity of this luminescent signal is directly proportional to the NO concentration. To quantify NO₂, the instrument incorporates a heated molybdenum (Mo) or stainless-steel catalytic converter that quantitatively reduces NO₂ to NO prior to reaction with O₃. NOₓ is reported as the sum of measured NO and catalytically converted NO₂. This method delivers high specificity, low detection limits (sub-ppb range), and excellent long-term reproducibility—critical for regulatory-grade air quality monitoring networks and compliance reporting.

Key Features

  • Integrated ozone generator with humidity-controlled gas path via desiccant drying tube—eliminates routine desiccant replacement and ensures stable O₃ yield across variable ambient humidity conditions.
  • Automatic temperature and barometric pressure compensation algorithms applied in real time to raw signal output, ensuring traceable concentration values per ISO 7935 and EPA Method 7E requirements.
  • Onboard self-diagnostic system with audible/visual alarms for critical fault conditions—including O₃ generator failure, photomultiplier tube (PMT) voltage drift, flow deviation, and converter efficiency loss.
  • Power-loss recovery functionality: automatic reinitialization and resume of measurement sequence following AC power interruption—essential for unattended station operation.
  • Flexible calibration architecture supporting both manual and remote zero/span verification using certified standard gases; full status logging of calibration events, gas concentrations, and operator IDs.
  • Multi-protocol communication interface: configurable RS-232 or RS-485 serial output (Modbus RTU); optional analog outputs—0–5 V DC and 4–20 mA current loop—fully isolated and NIST-traceable.

Sample Compatibility & Compliance

The XHN2000B is designed for use in fixed-site ambient air monitoring stations, mobile laboratories, and industrial fence-line monitoring applications. It accepts sample gas flows of 0.5–1.5 L/min at standard temperature and pressure (STP), with inlet filtration compliant with EN 14625 for particulate removal (≤2.5 µm). All wetted materials are chemically inert (e.g., electropolished stainless steel, PTFE-lined tubing) to prevent adsorption or catalytic decomposition of NO₂. The analyzer meets the performance specifications outlined in HJ 654–2013 (China’s Technical Requirements for Ambient Air Quality Monitoring Instruments) and has been independently verified by the China Environmental Monitoring Instrument Quality Supervision & Inspection Center. It also holds formal certification from the China Association of Environmental Protection Industry (CAPI), confirming conformance with GB/T 35211–2017 (Environmental Monitoring Instruments—General Technical Requirements).

Software & Data Management

The embedded firmware supports local data storage (≥30 days of 1-minute averaged records) with timestamped metadata including ambient T/P, PMT gain, O₃ concentration, and diagnostic flags. Data export is supported via USB mass storage or serial dump in ASCII CSV format, compatible with national air quality data platforms (e.g., CNEMC’s AQMS). Remote configuration and firmware updates are enabled via secure serial command set. Audit trails—recording all parameter changes, calibration actions, and alarm events—are retained with immutable timestamps, satisfying GLP-aligned data integrity requirements for environmental laboratories.

Applications

  • Ambient air quality monitoring networks operated by provincial and municipal ecological environment bureaus.
  • Compliance verification for stationary sources under China’s “Emission Standards of Air Pollutants for Thermal Power Plants” (GB 13223) and “Boiler Atmospheric Pollutants Emission Standard” (GB 13271).
  • Urban traffic pollution studies, particularly near tunnels and major intersections where NOₓ dynamics exhibit rapid temporal gradients.
  • Research applications in atmospheric chemistry requiring high-frequency NO/NO₂ speciation, including photochemical box modeling validation and ozone production efficiency analysis.
  • Integration into multi-parameter Automatic Air Quality Monitoring Systems (AAQMS) alongside SO₂, CO, O₃, PM₂.₅, and meteorological sensors.

FAQ

What is the detection limit for NO and NO₂?
The instrument achieves a 3σ detection limit of ≤0.5 ppb for NO and ≤1.0 ppb for NO₂ (as NO-equivalent), based on 60-second averaging under typical operating conditions.
Does the analyzer require periodic catalyst replacement?
The Mo-based NO₂-to-NO converter is rated for ≥12 months of continuous operation under typical urban ambient conditions; lifetime validation data are included in the CAPI certification report.
Is the system compliant with international data integrity standards?
While not FDA 21 CFR Part 11-certified out-of-the-box, the audit trail structure, electronic signature support (via external authentication gateway), and write-once data storage architecture enable alignment with ISO/IEC 17025 and EU ILAC G3 requirements when deployed within validated QA/QC workflows.
Can the XHN2000B be integrated into SCADA or third-party EMS platforms?
Yes—Modbus RTU over RS-485 enables direct integration with industry-standard supervisory control systems; register mapping documentation is provided with each unit.