Empowering Scientific Discovery

Beifen Sanpu Multi-2025 Automated Alkylmercury Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Beifen Sanpu
Origin Beijing, China
Manufacturer Type Direct Manufacturer
Instrument Category Domestic
Model Multi-2025
Price USD 28,000 (approx.)
Instrument Type Laboratory Gas Chromatograph
Application Field Environmental Monitoring

Overview

The Beifen Sanpu Multi-2025 Automated Alkylmercury Analyzer is a dedicated dual-mode analytical platform engineered for trace-level quantification of methylmercury (MeHg) and ethylmercury (EtHg) in complex environmental and biological matrices. It integrates purge-and-trap sample enrichment with gas chromatographic separation and cold vapor atomic fluorescence detection (CV-AFS), operating in full compliance with U.S. EPA Method 1630 and Chinese standard methodologies including HJ 977–2018, HJ 1269–2022, and HJ 1268–2022. Unlike conventional GC-AFS systems requiring discrete instrumentation and manual interfacing, the Multi-2025 embeds hardware synchronization, thermal desorption control, and mercury-specific fluorescence detection within a single rack-mounted architecture—eliminating inter-system signal latency and cross-contamination pathways inherent in third-party coupling.

Key Features

  • Modular purge-and-trap compatibility: Accepts standardized pneumatic interfaces from commercial autosamplers (e.g., Tekmar, OI Analytical, and domestic equivalents), enabling seamless integration with existing laboratory infrastructure without hardware modification.
  • Dedicated alkylmercury separation column: Utilizes a packed capillary column with surface-modified OV-3 stationary phase, offering enhanced thermal stability (up to 1050 °C pyrolysis), reduced carryover, and extended service life (>2000 injections under routine use).
  • Integrated 3D-printed hydride generation module: Fabricated from mercury-inert polymer composite (PEEK-reinforced polyetherimide), this monolithic reaction chamber consolidates hydrogenation, gas–liquid separation, and vapor transport functions—reducing internal dead volume to <15 µL and eliminating tubing-induced memory effects.
  • Multi-element atomic fluorescence capability: Supports quantitative determination of As, Hg, Se, Sb, Bi, Cd, Pb, Te, Sn, Ge, Zn, and Cu per USP , ISO 17025, and GB/T 223.74–2019 requirements, with independent lamp current control and real-time intensity normalization.
  • Automated consumables monitoring: Tracks usage cycles for peristaltic pump tubing, hollow cathode lamps, and quartz cell windows; triggers maintenance alerts based on cumulative operational hours and signal drift thresholds.

Sample Compatibility & Compliance

The Multi-2025 accepts aqueous, slurry, tissue homogenate, and acid-digested solid extracts across pH 1–12 and salinity up to 3.5% w/v NaCl. Sample introduction supports 5–50 mL purge volumes with programmable sparging flow (20–100 mL/min) and cryo-focusing at −30 °C. All analytical protocols align with GLP-compliant data integrity frameworks: audit trails are time-stamped, user-authenticated, and immutable per FDA 21 CFR Part 11 Annex 11 requirements. Method validation documentation includes precision (RSD <4.2% at 0.05 ng/L MeHg), recovery (89–103% across spiked soil, fish tissue, and wastewater), and limit of quantitation (LOQ = 0.02 ng/L in water matrix).

Software & Data Management

  • Graphical instrument status dashboard: Real-time visualization of GC oven ramping, trap desorption temperature, AFS lamp warm-up, and carrier gas pressure stabilization.
  • Method-driven workflow engine: Enables creation of multi-step sequences—including acid leaching, sodium tetraethylborate derivatization, purge optimization, and post-run system flush—with configurable hold times and temperature gradients.
  • Regulatory-grade reporting: Export modules generate compliant PDF reports with embedded metadata (instrument ID, analyst signature, calibration curve residuals, QC check results), plus editable Word and Excel templates for internal QA review.
  • Data archival: Raw chromatograms (.cdf), spectral files (.spc), and audit logs (.xml) are stored in hierarchical directory structures meeting ISO/IEC 17025 Clause 7.5.2 retention policies (minimum 7 years).

Applications

Validated for regulatory analysis in environmental laboratories performing compliance testing under China’s “Soil Pollution Prevention and Control Action Plan” and the Ministry of Ecology and Environment’s “National Monitoring Scheme for Priority Pollutants.” Routine applications include methylmercury speciation in freshwater sediments (HJ 1269–2022), ethylmercury screening in aquaculture products (SNT 5517–2023), and total elemental profiling in herbal medicine (Chinese Pharmacopoeia 2020 Edition, General Chapter 0412). Additional use cases span clinical toxicology (whole blood Hg speciation), feed safety (EU Commission Regulation (EC) No 1881/2006), and semiconductor wastewater monitoring (SEMI F57).

FAQ

Does the Multi-2025 require external purge-and-trap instrumentation?
No—it operates as a standalone GC-AFS platform but provides standardized pneumatic and electrical interfaces for optional integration with third-party concentrators.
What is the maximum allowable chloride concentration in samples?
Up to 35 g/L NaCl has been verified without signal suppression or column degradation when using the optimized derivatization protocol.
Can the software generate 21 CFR Part 11-compliant electronic signatures?
Yes—user authentication employs role-based access control (RBAC) with PKI-backed digital certificates and biometric verification options.
Is method transfer supported from legacy atomic fluorescence systems?
Pre-configured migration wizards import calibration tables, peak identification rules, and QC acceptance criteria from common AFS platforms (e.g., SK-2003, AF-640A).
How often must the quartz fluorescence cell be cleaned?
Under continuous operation (8 h/day), cleaning is recommended every 120 injections; automated ultrasonic rinse cycles are scheduled via software-defined maintenance plans.