- All
- Favorite
- Popular
- Most rated
| Brand | Camsco |
|---|---|
| Dimensions | 6 mm OD × 4.5 in length |
| Sorbent | Tenax TA / Carboxen 1000 (dual-bed) |
| Conditioning | Pre-aged (baked out) |
| Cap | Stainless steel storage cap |
| Packaging | Individual sterile packaging |
| Compatibility | CDS thermal desorbers |
| Origin | Manufactured in USA, distributed by Sanpu (Beijing) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Water Bath Incubator Shaker |
| Model | THZ-82(A) |
| Timing Range | 0–120 min |
| Oscillation Frequency | Adjustable, 0–300 rpm |
| Oscillation Amplitude | 20 mm |
| Temperature Range | Ambient to 100 °C |
| Temperature Accuracy | ±0.5 °C |
| Oscillation Mode | Orbital (standard for THZ-82 series) |
| Tray Quantity | 1 |
| Power Supply | 220 V, 50 Hz |
| Heating Power | 1800 W |
| Water Bath Chamber Dimensions | 490 × 390 × 170 mm (L×W×H) |
| Overall Dimensions | 700 × 550 × 490 mm (L×W×H) |
| Construction | Stainless Steel Interior |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-2010 + AHS-20A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Vial Heating Temperature Range | Up to 200 °C |
| Valve & Transfer Line Temperature Control Range | Up to 200 °C |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL and 20 mL vials |
| Compliance | Designed for GB/T 5750.8–2006 and GB/T 5750.10–2006 methods |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | AHS-10A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Vial Heating Range | Ambient to 200 °C |
| Valve & Quantitation Loop Temperature Control Range | Ambient to 220 °C |
| Quantitation Loop Volume | 1 mL |
| Vial Capacity | 12 positions |
| Vial Size Compatibility | 10 mL or 20 mL |
| Temperature Control Accuracy | < ±0.5 °C |
| RSD (n=6, 40 ppm ethanol in water) | ≤1.5% |
| Purge Flow Rate | 0–500 mL/min (continuously adjustable) |
| Dimensions (L×W×H) | 200 × 360 × 420 mm |
| Weight | ~18 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | JAHS-20A Plus |
| Price | Upon Request |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL and 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Sample Heating Range | 40–220 °C (optional to 300 °C), ±0.5 °C stability |
| Valve & Transfer Line Heating Range | 40–220 °C (optional to 300 °C), ±0.5 °C stability |
| Pressure Control | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–1800 s |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–1800 s |
| Minimum Time Resolution | 1 ms |
| Carrier Gas Flow Control | EPC-compatible (optional) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB 2.0 |
| Compliance | ASTM D6866, ISO 11843-2, USP <467>, FDA 21 CFR Part 11 ready (with optional audit trail software module) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | 79-2 |
| Power Supply | AC 220 V ±10 V, 50 Hz |
| Motor Power | 20 W |
| Heating Power | 200 W |
| Speed Range | 0–2400 rpm (infinitely variable) |
| Bidirectional Cycle | 60 s forward / 60 s reverse |
| Continuous Operation | 8 h at medium speed, 4 h at high speed |
| Included Accessories | PTFE-coated stir bar, support rod with clamp, power cord with grounded plug |
| Safety | Grounded chassis, overheat protection circuitry (implied by design standard) |
| Brand | Beifen Sanpu |
|---|---|
| Model | NAHS-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Sample Positions | 20 |
| Sample Vial Capacity | 10 mL or 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 / 2 / 5 mL) |
| Sample Heating Range | 40–220 °C (extendable to 300 °C) |
| Valve & Transfer Line Heating Range | 40–220 °C (extendable to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Carrier Gas Flow Control | EPC-electronic pressure control (optional) |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Communication Interface | USB |
| Compliance | Compatible with ASTM D6866, ISO 11843-2, USP <467>, and FDA 21 CFR Part 11–compliant data handling when integrated with validated GC software |
| Brand | Beifen Sanpu |
|---|---|
| Model | GC-9860 with FID Detector + AHS-610 Headspace Sampler |
| Origin | Beijing, China |
| Manufacturer | Beifen Sanpu Instrument Co., Ltd. |
| Temperature Control Range | 450 °C |
| Oven Ramp Rate | 39 °C/min |
| Oven Cool-down Rate | 35 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–450 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–450 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ATDS-3430 |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 450 °C |
| Cryo-Focusing Trap Temperature Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Position Capacity | 1 tube |
| Dimensions | 380 × 220 × 410 mm |
| Weight | ~15 kg |
| Power Consumption | 500 W |
| Temperature Control Accuracy | < ±0.5 °C |
| RSD | ≤2.5% (for 0.05 μg benzene in methanol) |
| Second-Stage Heating Rate | >3000 °C/min |
| Peak Width | <3 s |
| Sample Tube Compatibility | OD ≤6.5 mm, L ≥150 mm |
| Brand | Sanfen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | PT-80A |
| Instrument Category | Water-and-Soil Integrated |
| Sample Tray Capacity | 80 positions |
| Injection Precision | RSD ≤ 3% |
| Trap Temperature Range | Ambient to 380 °C |
| Cooling | 250 °C → 35 °C in ≤ 90 s |
| Sample Heating (Liquid) | Ambient to 95 °C |
| Sample Chilling | Ambient only |
| Cold Trap Temperature | −40 °C to ambient (Peltier + air cooling) |
| Blowback Flow Separation | Yes |
| Foam Sensor | Integrated |
| PEEK & Silanized Stainless Steel Tubing | Yes |
| Hot Water Rinse Capability | Yes |
| GC/GC-MS Synchronization | Dual TTL outputs, 1–2 s trigger latency |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Safety Testing |
| Oven Temperature Range | 100–350 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Time (350→100 °C) | ~6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Quantitative Loop Volume | 1 mL |
| Sample Position Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL or 20 mL vials |
| Temperature Stability | < ±0.5 °C |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Communication Interface | USB |
| Compliance | GB/T 16886.7–2001, USP <467>, ISO 10993-7, ASTM D6866, HJ 642–2013, HJ 643–2013, HJ 714–2014, HJ 810–2016, ChP 2015 Vol. III & IV, FDA 21 CFR Part 11 (via compatible CDS) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | LH-24A |
| Temperature Control Range | Ambient to 400 °C |
| Gas Flow Rate | 0–500 mL/min (expandable to 0–1000 mL/min per specification) |
| Tube Capacity | 24 adsorption tubes |
| Control Accuracy | ±1 °C |
| Max Aging Duration | >999 h |
| Dimensions (H×W×D) | 350 mm × 230 mm × 330 mm |
| Net Weight | ~12 kg |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | <200 VA |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Gas Chromatograph |
| Model | GC-3420A |
| Price Range | USD 4,200 – 7,000 |
| Application Field | General-purpose Environmental Air Monitoring |
| Temperature Control Range | Ambient to 400 °C |
| Ramp Rate | Up to 40 °C/min |
| Cooling Rate | Forced air cooling, <5 min from 300 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–100 mL/min (N₂, H₂, He), electronic pressure/flow control (EPC) |
| Inlet Pressure Range | 0–100 psi |
| Maximum Inlet Temperature | 450 °C |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Beifen Sanpu Instruments Co., Ltd. |
| Model | A’HS-20A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 20-position carousel |
| Compatible Vial Sizes | 10 mL or 20 mL vials |
| Compliance Standard | HJ 1067–2019 |
| Brand | Beifen Sanpu |
|---|---|
| Model | GC-9860-FID |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Alcoholic Beverage Chromatography |
| Oven Temperature Range | 450 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Oven Cool-down Time | ~8 min |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–1000 kPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Setting Range | 0–1000 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | FTDS-III |
| Pricing | Upon Request |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TAHS-20A Plus |
| Sample Positions | 20 |
| Sample Vial Capacity | 10 mL or 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 / 2 / 5 mL) |
| Sample Heating Range | 40–220 °C (extendable to 300 °C) |
| Valve & Transfer Line Heating Range | 40–220 °C (extendable to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Time Resolution | 1 ms |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Communication Interface | USB |
| Automation Mode | Motor-driven actuation (no external gas required) |
| Compliance | ASTM D6866, ISO 11843-2, USP <467>, FDA 21 CFR Part 11 (with optional audit trail software)] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Gas Chromatograph |
| Model | GC9860-IV |
| Temperature Control Range | 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–39 °C/min |
| Cooling Rate | ~6 min (450 °C → 50 °C) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Accuracy | ±0.05 kPa |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | ±0.05 kPa |
| Total Injector Flow Setting Range | 0–1200 mL/min |
| Temperature Zones | 6 independent zones |
| Temperature Increment | 1 °C |
| Temperature Stability | ±0.1 °C |
| Programmed Temperature Steps | 16 |
| External Events | 8 channels |
| Auxiliary Outputs | 4 channels |
| Supported Inlet Types | Packed column, capillary column, 6-port gas valve, headspace auto-sampler |
| Detector Capacity | Up to 3 simultaneous detectors |
| Compatible Detectors | FID, TCD, ECD, FPD, NPD |
| Gas Control Mode | Full Electronic Pressure Control (EPC) |
| EPC Operating Modes | Constant Flow, Constant Pressure |
| Supported Carrier Gases | N₂, H₂, Air, He, Ar |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | AH-S-20A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL vials |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Control Range | 40–220 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Loop Volume | 1 mL |
| Key | Brand: Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical & Cosmetic Quality Control |
| Max Oven Temperature | 450 °C |
| Heating Rate | 0.1–80 °C/min |
| Cooling Rate | 40 °C/min |
| Carrier Gas Flow Range | 0–1200 sccm |
| Carrier Gas Pressure Range | 0–0.4 MPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Set Range | 0–0.4 MPa |
| Injector Total Flow Set Range | 0–1200 sccm |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | AHS-20A PLUS |
| Instrument Type | Laboratory Water Quality Analyzer |
| Target Analytes | Volatile Organic Compounds (VOCs) |
| Detection Method | Headspace-Gas Chromatography with Flame Ionization Detection (HS-GC-FID) |
| Compliance Standards | GB 5749-2006, GB 3838-2002, GB 8537-2008 |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | AvHS-20A PLUS |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HH-S |
| Power Supply | 220 V ±10 V, 50 Hz |
| Temperature Control Range | Ambient to 300 °C |
| Chamber Dimensions (W × D × H) | 280 × 280 × 300 mm |
| Heating Power | 2500 W |
| Safety Features | Grounding Terminal Required, Immersion-Only Operation for Heating Element |
Show next