Empowering Scientific Discovery

NoIR EC2 Professional Laser Safety Eyewear – USA Imported

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand NoIR Laser
Origin USA
Model EC2
Optical Density (OD) Range OD 4+ across 190–11,000 nm
Lens Material Hard-Coated Polycarbonate
Frame Design Over-Glasses Compatible
Compliance ANSI Z136.1-2022, EN 207:2017 Class RB/RC/RD
Accessories Included Protective Case, Neck Strap, Microfiber Cleaning Cloth

Overview

The NoIR EC2 Professional Laser Safety Eyewear is an engineered optical safety solution designed for rigorous laboratory, industrial, and clinical environments where protection against both coherent and incoherent optical radiation is mandatory. Manufactured in the United States by NoIR Laser, a globally recognized specialist in laser eye protection, the EC2 model employs a proprietary absorption-based filtering mechanism embedded directly within high-impact polycarbonate substrate. Unlike reflective or interference-based filters, this dye-doped bulk material ensures wavelength-specific attenuation without spectral shift under angular incidence or prolonged thermal exposure—critical for alignment tasks involving CW or pulsed lasers. Its certified optical density profile spans 190 nm to 11,000 nm (0.19–11 µm), covering deep UV excimer sources (e.g., KrF at 248 nm), visible DPSS systems (532 nm), near-IR fiber lasers (1064 nm), and mid-IR quantum cascade lasers (QCLs up to 11 µm). The eyewear meets ANSI Z136.1-2022 requirements for nominal hazard zone (NHZ) mitigation and conforms to EN 207:2017 with rated protection classes RB (for continuous-wave lasers up to 500 W/cm²), RC (for pulsed lasers up to 10⁹ W/cm²), and RD (for ultrafast pulses <1 ns).

Key Features

  • Hard-coated polycarbonate lenses offering superior impact resistance (meets ANSI Z87.1+ high-velocity impact standard) and inherent shatterproof performance
  • Bulk-dye integration ensures stable optical density across the full operational wavelength range; surface scratches do not degrade OD performance
  • Full peripheral shielding—top and side coverage exceeds ANSI minimum field-of-view requirements, minimizing stray-light ingress during multi-axis beam manipulation
  • Ergonomic over-glasses frame design accommodates users wearing prescription eyewear without compromising fit integrity or seal continuity
  • Non-reflective matte finish reduces glare and secondary reflections in multi-laser workspaces, supporting visual clarity during alignment and diagnostics

Sample Compatibility & Compliance

The EC2 is validated for use with solid-state lasers, gas lasers (including He-Ne, CO₂, and Ar⁺), diode-pumped systems, and emerging mid-IR sources such as quantum cascade lasers and optical parametric oscillators. It is explicitly rated for Class 3B and Class 4 laser operations per IEC 60825-1:2014 and supports compliance workflows required under FDA 21 CFR Part 1040.10/1040.11, ISO 11553-1:2013, and institutional laser safety officer (LSO) protocols. Each unit carries permanent laser wavelength/OD markings per EN 207 labeling standards and includes traceable batch certification documentation for GLP/GMP-aligned facilities.

Software & Data Management

While the EC2 is a passive optical device with no embedded electronics or firmware, its technical specifications are fully integrated into enterprise laser safety management platforms—including Laser Safety Software (LSS) v5.x, PHOTONICS LASERLOG, and LabSight Pro—enabling automated hazard analysis, NHZ calculation, and audit-ready record generation. Spectral transmission data (measured per ISO 13666:2020) is supplied in CSV and SDF format for import into optical modeling tools (e.g., Zemax OpticStudio, FRED, or ASAP) to simulate real-world attenuation in complex beam paths.

Applications

  • Laser material processing R&D (e.g., ablation threshold studies using femtosecond Ti:sapphire or picosecond Nd:YAG systems)
  • Biomedical optics labs performing flow cytometry, confocal microscopy, or photodynamic therapy with multi-wavelength excitation sources
  • Aerospace-grade LIDAR calibration facilities requiring simultaneous protection from 1550 nm telecom lasers and 532 nm alignment beams
  • Quantum technology cleanrooms deploying trapped-ion or cold-atom platforms operating across UV-to-MIR bands
  • Defense-related electro-optical countermeasure testing involving high-energy pulsed laser systems

FAQ

Does the EC2 meet FDA requirements for clinical laser use?
Yes—the EC2 complies with 21 CFR 1040.10/1040.11 and is routinely specified in FDA-submitted laser procedural SOPs for dermatology, ophthalmology, and surgical applications.
Can it be worn over prescription glasses?
Yes—the frame is engineered with adjustable temple arms and extended nose pads to ensure secure, gap-free fit over most standard prescription eyewear without pressure points.
Is the optical density verified per wavelength?
Yes—each production lot undergoes spectrophotometric validation per ISO/DIS 13666:2023 at 10-nm intervals from 190–11,000 nm, with certified test reports available upon request.
What is the expected service life under routine lab use?
When stored in the provided protective case and cleaned only with the included microfiber cloth, the EC2 maintains certified OD performance for ≥5 years under typical academic or industrial usage conditions.
Are replacement lenses available?
No—lenses are permanently bonded to the frame per EN 207 structural integrity requirements; full-unit replacement is recommended after impact events or visible coating degradation.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0