Lohand LH-A116 Intelligent Multi-Parameter COD Digestion System
| Brand | Lohand |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | LH-A116 |
| Pricing | Upon Request |
| Digestion Method | Rapid Digestion |
| Heating Module | Single Aluminum Block Heater |
| Batch Capacity | 16 Samples |
| Temperature Range | 40–190 °C (User-Adjustable) |
| Temperature Accuracy | ±0.5 °C |
| Sample Volume Capacity | 0–10 mL |
| Timer Drift | ≤0.2 s/hour |
Overview
The Lohand LH-A116 Intelligent Multi-Parameter COD Digestion System is a precision-engineered benchtop thermal digestion unit designed for standardized chemical oxygen demand (COD), total phosphorus (TP), total nitrogen (TN), and other redox-sensitive water quality parameter determinations in accordance with ISO 6060, ASTM D1252, and HJ 828–2017 (Chinese EPA method). It implements rapid closed-vessel digestion via precisely regulated conductive heating through a monolithic aluminum block, ensuring uniform thermal distribution across all 16 sample positions. Unlike conventional open-reflux systems, the LH-A116 employs programmable ramp-and-hold temperature profiles to accelerate oxidation kinetics while minimizing reagent consumption and operator exposure to hazardous fumes. Its architecture complies with GLP-aligned laboratory practices—supporting traceable, repeatable, and auditable digestion protocols essential for environmental compliance testing, municipal wastewater monitoring, and third-party certification laboratories.
Key Features
- Programmable temperature control from 40 °C to 190 °C in 1 °C increments, with real-time feedback regulation maintaining ±0.5 °C stability across the full operating range.
- Dual-mode timer system: fixed-duration digestion (1–120 min) and continuous hold mode; timer drift limited to ≤0.2 s/hour for long-duration method validation.
- Digitally labeled 16-position digestion block with engraved numeric identifiers for unambiguous sample tracking and cross-method correlation.
- Integrated thermal insulation layer on the upper surface of the heating block to reduce surface temperature to <50 °C during operation—meeting IEC 61000-3-2 touch-safety thresholds.
- Full-height transparent polycarbonate safety shield rated to 200 °C, enabling real-time visual monitoring of digestion progress without compromising containment integrity.
- Adaptive power modulation algorithm that reduces heating element duty cycle upon reaching setpoint—minimizing thermal overshoot and extending heater lifespan.
- Capacitive 7-inch TFT-LCD touchscreen interface with Chinese-language UI, supporting multi-level user permissions (operator, supervisor, administrator) and audit-trail logging of all parameter changes.
Sample Compatibility & Compliance
The LH-A116 accommodates standard 16-mm OD borosilicate glass digestion tubes (0–10 mL volume), compatible with common COD reagent kits including dichromate-based (HJ 828–2017), permanganate-based (ISO 8467), and proprietary low-chloride interference formulations. All digestion protocols are validated for use with domestic and industrial wastewater, surface water, groundwater, and treated effluent matrices. The system meets mechanical safety requirements per GB/T 25631–2010 (Chinese national standard for laboratory heating equipment) and electromagnetic compatibility per GB 4824–2019 (CISPR 11 Class B). Optional RS-232/USB data export enables integration into LIMS environments compliant with ISO/IEC 17025:2017 documentation requirements.
Software & Data Management
The embedded firmware supports 21 pre-validated digestion programs—including 16 factory-loaded methods aligned with national and international standards (e.g., COD at 150 °C/120 min, TP at 120 °C/30 min) and five fully customizable slots for user-defined ramp/hold sequences. Each program stores temperature setpoint, dwell time, cooling delay, and audio alert configuration. All operational events—including power-on, parameter edits, start/stop commands, and alarm triggers—are timestamped and stored locally for ≥10,000 cycles. Data export is supported via USB mass storage or serial ASCII dump for traceability under FDA 21 CFR Part 11–aligned workflows when paired with validated external software. No cloud connectivity or remote access functionality is implemented—ensuring full data sovereignty.
Applications
- Routine COD analysis in municipal wastewater treatment plants (WWTPs) for process control and discharge compliance reporting.
- Regulatory monitoring of industrial effluents per local environmental protection bureau mandates (e.g., China MEP Order No. 39).
- Research-grade digestion for method development and inter-laboratory comparison studies involving TN, TP, and heavy metal leaching protocols.
- Educational use in university environmental engineering labs where reproducibility, safety, and intuitive operation are pedagogical priorities.
- Field-deployable support for mobile environmental testing units requiring compact, robust, and low-maintenance thermal digestion capability.
FAQ
Does the LH-A116 support external temperature calibration verification?
Yes—users may insert an NIST-traceable PT100 probe into designated calibration ports adjacent to the heating block for independent accuracy validation against internal thermistor readings.
Can digestion programs be exported or backed up?
Program configurations can be saved to USB flash drives in encrypted .cfg format; restoration requires administrator-level authentication.
Is the safety shield autoclavable or chemically resistant?
The polycarbonate shield resists concentrated sulfuric acid, potassium dichromate solutions, and 30% hydrogen peroxide; however, it is not autoclavable—cleaning is recommended with ethanol or mild detergent.
What maintenance intervals are recommended for long-term reliability?
Heating block surface inspection and thermal paste reapplication every 12 months; fan filter replacement every 6 months under continuous operation.
Does the instrument meet CE or UKCA marking requirements?
The LH-A116 is CE-marked per Directive 2014/30/EU (EMC) and 2014/35/EU (LVD); UKCA marking is available upon request with UK-recognized notified body documentation.