Empowering Scientific Discovery

IKA ICC basic eco 8 Immersion Circulator System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand IKA
Origin Germany
Model ICC basic eco 8
Heating Power 2000 W
Temperature Range –20 °C to 150 °C
Temperature Stability (DIN 12876 Class III) ±0.02 K
Display Resolution ±0.1 °C
Control Sensor PT100
Safety Sensor PT1000
Pump Type Pressure/Suction Circulator
Max Flow Rate 18 L/min at 0 bar
Max Pressure 0.3 bar
Max Suction 0.2 bar
Adjustable Flow Yes
Bath Minimum Depth 150 mm
Calibration Option Yes
Protection Rating IP21 (DIN EN 60529)
Interfaces RS232, USB
Input Voltage 230/115 V, 50/60 Hz
Rated Power Input 2100 W
Dimensions (W×H×D) 145 × 340 × 200 mm
Weight 3.75 kg
Ambient Operating Conditions 5–40 °C, ≤80% RH
Continuous Duty Cycle 100%
Safety Features Dual-Stage Overtemperature Protection (adjustable 0–160 °C), Overvoltage Protection, Secondary Safety Circuit, Visual & Audible Alarms (High/Low Temp, Sensor Fault)

Overview

The IKA ICC basic eco 8 Immersion Circulator System is a DIN 12876 Class III-certified compact immersion circulator engineered for precision temperature control in external baths, jacketed reactors, and flow-through applications. Based on Peltier-assisted thermoelectric cooling combined with high-efficiency resistive heating, the system delivers stable thermal regulation across an extended operating range from –20 °C to +150 °C—enabling both cryogenic and high-temperature experimental protocols without requiring external chillers or auxiliary heaters. Its core architecture integrates a dual-sensor safety architecture: a primary PT100 sensor for active temperature control and a redundant PT1000 safety sensor with independently adjustable upper/lower limits (0–160 °C), compliant with DIN 12876-1 requirements for Class III devices used in laboratories handling hazardous or temperature-sensitive materials. The unit’s 2000 W heating output and optimized pump hydraulics support rapid thermal equilibration and uniform heat distribution—even in large-volume or high-thermal-mass systems.

Key Features

  • DIN 12876 Class III certification for use in safety-critical laboratory environments involving flammable, toxic, or biologically sensitive samples
  • Integrated pressure/suction circulation pump with fully adjustable flow (0–18 L/min) and dual-pressure capability (0.3 bar max pressure / 0.2 bar max suction)
  • High-resolution LED display with simultaneous readout of process temperature, safety limit status, and pump operation mode
  • ±0.02 K temperature stability (at setpoint, per DIN 12876 test conditions) and ±0.1 K control accuracy supported by PID algorithm with adaptive tuning
  • Comprehensive alarm system: visual (LED) and audible alerts for overtemperature, undertemperature, sensor failure, and safety circuit activation
  • RS232 and USB interfaces for instrument control, data logging, and integration into LIMS or automated workflows under GLP/GMP-compliant audit trails
  • IP21 ingress protection (DIN EN 60529) ensures operational reliability in standard laboratory environments with moderate dust and non-vertical water exposure
  • 100% continuous duty cycle rating validated per IEC 61000-3-2; no derating required during prolonged operation

Sample Compatibility & Compliance

The ICC basic eco 8 is designed for external bath circulation—not direct sample immersion—and is compatible with glass, stainless steel, and PTFE-lined vessels meeting minimum depth requirements (≥150 mm). It supports aqueous, silicone oil, ethylene glycol/water, and low-viscosity organic media (e.g., toluene, xylene) within its specified temperature and chemical resistance envelope. All electrical and thermal safety mechanisms comply with DIN 12876-1:2015, EN 61010-1 (Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use), and IEC 61326-1 (EMC for Laboratory Equipment). Optional factory calibration certificates traceable to DAkkS-accredited standards are available upon request to satisfy ISO/IEC 17025 documentation requirements.

Software & Data Management

Instrument configuration, real-time monitoring, and event-triggered data export are supported via IKA’s free Labworldsoft software (v5.0+), which provides full remote control, multi-channel logging (temperature, flow, alarm states), and configurable export formats (CSV, XML) compatible with statistical process control (SPC) platforms. USB and RS232 interfaces support time-stamped audit logs with user authentication (via optional password-protected access levels), fulfilling FDA 21 CFR Part 11 requirements for electronic records when deployed in regulated QC/QA environments. Firmware updates preserve all user-defined parameters and calibration offsets, ensuring continuity during maintenance cycles.

Applications

  • Temperature-controlled enzymatic assays and protein stability studies requiring sub-0.1 K thermal consistency
  • Calibration of reference thermometers, RTDs, and thermocouples against NIST-traceable standards
  • Viscometry and rheology testing where bath temperature directly influences fluid viscosity measurements
  • Accelerated stability testing per ICH Q1A(R2) guidelines using controlled thermal stress profiles
  • Reaction calorimetry support for exothermic/endothermic process monitoring in jacketed reactors
  • Environmental simulation chambers requiring precise external coolant loop management

FAQ

Can the ICC basic eco 8 operate continuously at –20 °C in ambient conditions above 25 °C?
Yes—its thermoelectric cooling stage is rated for continuous operation at –20 °C ambient up to 30 °C; performance degrades gradually above that due to condensation risk and reduced COP, but remains within specification up to 40 °C ambient if humidity is controlled.
Is external bath fluid level monitoring supported?
No—the unit does not include ultrasonic or capacitive level sensing; users must ensure minimum bath depth (150 mm) is maintained manually or via external interlock circuits connected through digital I/O (available on RS232 protocol extensions).
Does the device meet USP & ASTM temperature uniformity requirements for dissolution testing?
While not specifically validated for USP , its ±0.02 K stability and flow-adjustable circulation make it suitable for custom dissolution bath configurations when paired with ISO 17025-accredited verification protocols.
Can the safety temperature limit be locked to prevent unauthorized changes?
Yes—Labworldsoft enables administrator-level password protection for all safety parameter edits, and hardware write-protection can be enabled via DIP switch configuration for GxP-regulated installations.

InstrumentHive