SCI-025 Fixed-Position Automatic Water Sampler with Refrigerated Storage and Exceedance-Based Retention Sampling
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SCI-025 |
| Instrument Type | Laboratory-Grade Fixed-Position Water Sampler |
| Cooling Range | 4 °C ±1 °C |
| Sample Bottle Capacity | 1000 mL × 24 positions |
| Vertical Suction Lift | 8 m |
| Sampling Volume Range | 1–9999 mL per aliquot |
| Sampling Interval | 1–9999 min |
| Volumetric Sampling Accuracy | ±5% |
| Proportional Sampling Accuracy | ±10% |
| Data Storage | 10,000 sampling events, 2 years of flow data, 2,000 alarm logs |
| Power Supply | AC 220 V ±15%, with 3.3 V backup Li-ion clock battery |
| Dimensions (W×D×H) | 100 cm × 75 cm × 55 cm |
| Weight | ≤35 kg |
Overview
The SCI-025 Fixed-Position Automatic Water Sampler is an engineered solution for regulatory-compliant, long-term wastewater and surface water monitoring in fixed-site applications. Designed to meet China’s HJ/T 372–2007 and HJ/T 92–2017 technical specifications for environmental monitoring instrumentation, the system implements programmable, flow-synchronized, and event-triggered sampling using a precision peristaltic pump with 8-meter vertical suction capability. Its core function is to support generation of representative composite or discrete samples for subsequent laboratory analysis—particularly for calculating daily average pollutant concentrations (e.g., COD, NH₃-N, TP, heavy metals) required under national discharge permit regimes. Integrated refrigerated storage at 4 °C ±1 °C ensures sample integrity during holding periods, while exceedance-based retention logic enables automatic preservation of samples when real-time sensor inputs (e.g., pH, conductivity, turbidity, or optional online analyzers) breach preconfigured thresholds—fully traceable and audit-ready.
Key Features
- Programmable multi-mode sampling: time-proportional, volume-proportional, flow-proportional, level-proportional, and manual-triggered acquisition.
- Dual-function temperature control system: digitally regulated refrigeration and auxiliary heating to maintain stable 4 °C storage across ambient fluctuations.
- 24-position sample rack accommodating standard 1000 mL HDPE or glass bottles; supports single-sample-per-bottle, multi-aliquot-per-bottle, and multi-bottle composite configurations.
- High-fidelity peristaltic pumping with microstepping motor and细分 driver—low-noise operation (<45 dB), minimal pulsation, and consistent volumetric delivery.
- Comprehensive I/O interface suite: dual RS232/RS485 ports, 4–20 mA analog input/output, dry-contact trigger inputs, pulse signal reception, and optional GSM/SMS remote command module.
- Automated tube pre-rinse and post-sampling line purge to prevent cross-contamination and ensure representative intake.
- Real-time clock with <10-second monthly drift; non-volatile memory retains all configuration parameters, sampling programs, and timestamps during power loss.
- User-accessible 10-program memory bank, each supporting nested conditional logic (e.g., “if flow > X L/s AND pH < 6.0 → initiate retention sampling”).
- Front-panel blue-backlit Chinese LCD with 3×5 membrane keypad; password-protected parameter editing and operational mode switching.
Sample Compatibility & Compliance
The SCI-025 is validated for use with municipal wastewater, industrial effluents, and surface water matrices within pH 2–12 and suspended solids ≤150 mg/L. Its peristaltic tubing (FDA-compliant silicone or Viton® variants, field-replaceable) resists chemical degradation from common contaminants including chlorinated solvents, low-concentration acids/bases, and surfactants. The system complies with GB/T 38394–2019 (General Technical Requirements for Automatic Water Samplers) and aligns with ISO 5667-10:2021 (Water quality — Sampling — Part 10: Guidance on sampling of wastewater). For GLP/GMP-aligned deployments, audit trails—including sampling start/stop timestamps, bottle assignment, volume delivered, temperature log, and trigger source—are stored internally and exportable via serial protocol. Optional printer integration supports on-site hardcopy verification per internal QA protocols.
Software & Data Management
Data logging occurs autonomously without PC dependency: 10,000 sampling records (including bottle ID, volume, timestamp, trigger type), 2-year rolling flow statistics (hourly/daily/monthly/yearly), and 2,000 event alarms (e.g., low battery, door open, temperature excursion, pump stall) are retained in EEPROM. Communication follows ASCII-based Modbus RTU or proprietary ASCII command set over RS232/RS485. PC software (Windows-compatible, supplied on USB drive) enables program upload/download, historical data extraction (CSV/Excel), graphical flow–sampling correlation plots, and certificate-of-operation report generation. All configuration changes are logged with user ID and timestamp—supporting FDA 21 CFR Part 11 readiness when paired with role-based access control on host systems.
Applications
- Effluent compliance monitoring at municipal wastewater treatment plants (WWTPs) and industrial outfalls.
- Integration with online analyzers (e.g., UV-Vis COD, ion-selective electrode NH₄⁺) for automatic retention upon parameter exceedance.
- Long-term unattended sampling campaigns for seasonal pollutant load assessment in rivers and reservoirs.
- Supporting national “Total Discharge Control” initiatives requiring daily mean concentration reporting to provincial EPBs.
- Pre-treatment verification sampling in pharmaceutical, electroplating, and textile manufacturing facilities.
FAQ
What is the maximum allowable total suspended solids (TSS) concentration for reliable sampling?
The system is rated for continuous operation with TSS ≤150 mg/L. For higher-load applications, optional filtration modules or scheduled maintenance intervals must be implemented.
Can the SCI-025 interface with third-party SCADA platforms?
Yes—via Modbus RTU over RS485 or 4–20 mA analog output mapped to flow rate or sample count; full register map and protocol documentation are provided.
Is the refrigeration system certified for continuous 24/7 operation?
Yes—the compressor-based cooling subsystem is rated for indefinite duty cycle at 4 °C ambient up to 40 °C, with thermal overload protection and condensate management.
How is calibration traceability maintained for volumetric accuracy?
Peristaltic pump delivery is factory-calibrated using gravimetric NIST-traceable methodology; users may perform field verification using certified volumetric flasks and analytical balance (±0.1 g resolution recommended).
Does the system support remote firmware updates?
Firmware upgrades require local USB connection and authenticated software utility; no over-the-air update capability is implemented for security and regulatory stability.