Empowering Scientific Discovery

Hanna Instruments HI9143 Portable High-Accuracy Dissolved Oxygen Meter

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Origin Germany
Manufacturer Type Authorized Distributor
Origin Category Imported
Model HI9143
Pricing Available Upon Request

Overview

The Hanna Instruments HI9143 is a field-deployable, electrochemical dissolved oxygen (DO) meter engineered for precision and reliability in demanding environmental monitoring applications. It operates on the polarographic (Clark-type) principle, utilizing a membrane-covered galvanic or polarographic sensor to measure oxygen partial pressure in aqueous solutions. The instrument converts this signal into concentration units (mg/L or ppm) and saturation percentage (% air saturation), with built-in thermistor-based temperature measurement enabling real-time compensation. Designed specifically for water and wastewater analysis—including surface water, groundwater, effluent streams, and aquaculture systems—the HI9143 delivers trace-level DO resolution without requiring laboratory-grade infrastructure. Its ruggedized IP67-rated housing ensures operational integrity under rain, dust, high humidity (up to 100% RH), and transient submersion—making it suitable for riverbank surveys, stormwater outfall inspections, and remote treatment plant audits.

Key Features

  • Polarographic DO sensing with integrated Pt cathode and Ag/AgCl anode, coupled with a gas-permeable Teflon membrane for stable diffusion-limited current response
  • Simultaneous dual-parameter display: DO concentration (0.00–45.00 mg/L), % saturation (0.0–300.0%), and temperature (0.0–50.0 °C)
  • Automatic single-point calibration in ambient air (100% O₂ reference), eliminating manual potentiometer adjustment or calibration tools
  • Comprehensive environmental compensation: automatic temperature compensation (0.0–50.0 °C), salinity compensation (0–40 g/L, adjustable in 1 g/L increments), and barometric pressure compensation via altitude input (0–1900 m, 100 m resolution)
  • HI76407-series DO probe with built-in NTC thermistor and 4-meter reinforced cable; replaceable membranes (HI76407A/P) and electrolyte (HI7041S) ensure long-term sensor maintenance compliance
  • Compact ergonomic design (196 × 80 × 60 mm; 500 g) with backlit LCD, low-power consumption, and AC/DC adapter support (230 VAC / 12 VDC) for extended field operation

Sample Compatibility & Compliance

The HI9143 is validated for use with freshwater, seawater, brackish water, activated sludge, and treated effluents. Its measurement methodology conforms to standard practices referenced in ASTM D888-22 (“Standard Test Methods for Dissolved Oxygen in Water”) and ISO 5814:2012 (“Water quality — Determination of dissolved oxygen — Electrochemical probe method”). The instrument supports GLP-compliant data handling through timestamped calibration logs and user-accessible configuration settings. While not intrinsically rated for hazardous locations, its ingress protection (IP67) meets IEC 60529 requirements for temporary immersion and particulate exclusion—critical for field technicians working in uncontrolled outdoor environments.

Software & Data Management

The HI9143 operates as a standalone instrument with no embedded Bluetooth or USB connectivity; however, all calibration events, measurement modes, and compensation parameters are retained in non-volatile memory across power cycles. Calibration history—including date/time stamp, ambient temperature, and applied compensation values—is accessible via on-screen navigation. For integration into larger QA/QC workflows, users may manually transcribe readings into LIMS or spreadsheet-based tracking systems. Documentation supplied with each unit includes a manufacturer’s certificate of conformance, electrode installation guide, and maintenance schedule aligned with EPA Method 360.5 and ISO/IEC 17025 documentation expectations.

Applications

  • Regulatory compliance monitoring at NPDES discharge points and drinking water intakes
  • Biochemical oxygen demand (BOD) incubation verification and wastewater treatment process control (e.g., aeration basin optimization)
  • Aquatic ecosystem assessment: hypolimnetic oxygen profiling in lakes/reservoirs, wetland health screening
  • Industrial cooling tower and boiler feedwater system surveillance
  • Educational field laboratories and environmental science coursework requiring portable, standards-aligned DO instrumentation

FAQ

What calibration standard is required for the HI9143?

The instrument performs automatic single-point calibration using ambient air (20.9% O₂ at sea level) as the reference; no certified gas standards or liquid calibrants are needed.
Can the HI9143 be used in seawater?

Yes—its salinity compensation range (0–40 g/L) covers full-strength seawater (~35 g/L); users must enter local salinity prior to measurement for accurate mg/L conversion.
Is the HI76407/4 probe compatible with other Hanna meters?

The HI76407 series is mechanically and electrically optimized for the HI9143 platform; while physically interchangeable with some legacy meters, full functionality—including auto-recognition and compensation logic—is guaranteed only on the HI9143.
How often should the membrane and electrolyte be replaced?

Hanna recommends replacing the HI76407A/P membrane and HI7041S electrolyte every 2–4 weeks under continuous use, or immediately after exposure to sulfides, heavy metals, or organic fouling agents.
Does the HI9143 meet FDA 21 CFR Part 11 requirements?

No—the device lacks electronic signature capability, audit trail generation, or user access controls; it is intended for field screening rather than regulated GMP/GLP production environments.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0