| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SCI-100E |
| Price | USD 12,000 (FOB Beijing) |
| Measurement Range | 0–1999.999 mN/m |
| Resolution & Sensitivity | 0.001 mN/m |
| Detection Methods | Du Noüy Ring Method, Wilhelmy Plate Method |
| Sampling Interval | 0.1 Hz (standard), 0.02 Hz (optional) |
| Vertical Travel | 0–50 mm (standard), up to 110 mm (optional) |
| Positioning Accuracy | 0.1 µm |
| Force Sensor | High-precision 0.1 mg electromagnetic balance (Mettler Toledo OEM) |
| Temperature Control Support | External thermostatic bath interface (−20 °C to +95 °C, optional) |
| Data Output | Real-time tension curve logging, CSV export, on-device LCD display + thermal printer (integrated) |
| Compliance | SY/T 5370–1999 |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PF204plus / PF216plus |
| Pricing | Available Upon Request |
| Accuracy | ±0.5–2% of reading (ID 13–75 mm, flow velocity >0.2 m/s) |
| Pipe ID Range | PF204plus: 13–115 mm |
| PF216plus | 50–1000 mm |
| Sensor Operating Temperature | –20 °C to +135 °C (Groups A & B) |
| Output | Optically isolated 0/4–20 mA |
| pulse output | 1 pulse/sec, max 5 V |
| Velocity Range | 0.1–20 m/s |
| Display | 64 × 240 pixel graphical LCD |
| Power | Rechargeable battery (20 h typical runtime) or 110/240 VAC ±10% via external PSU |
| Certifications | CE compliant |
| Enclosure | Polypropylene carrying case with custom-cut foam insert |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SMP30 |
| Price Range | USD 1,400–2,800 |
| Sample Capacity | 3 capillaries |
| Temperature Range | Ambient to 400 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating Rate | 0.5–10.0 °C/min (0.1 °C increments) |
| Temperature Memory | 8 readings per sample |
| Sensor | PT100 platinum resistance thermometer |
| Cooling | Integrated air pump |
| Dimensions | 325 × 200 × 170 mm |
| Net Weight | 3.6 kg |
| Power Supply | 230 V, 50/60 Hz, 60 W |
| Standard Accessories | Glass capillary tubes (SMP10/1) |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HD-2000 |
| Price Range | USD 700–1,400 |
| Instrument Class | Dose Rate Meter |
| Form Factor | Portable |
| Measured Quantity | Ambient Gamma Photon Dose Rate |
| Detector Type | Scintillation-based Environmental Radiation Sensor |
| Measurement Range | (0.01–100) µGy/h |
| Sensitivity | ≥350 s⁻¹ at 1 µGy/h (equivalent to 10³ nGy/h) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PGM6208 |
| Instrument Type | Portable |
| Detection Targets | Multi-component (EC, LEL, TC, PID, IR, Gamma) |
| Measurement Range | 0–1 ppm (select sensors) |
| Repeatability | ≤1% FS |
| Resolution | 0.1 ppm (standard) |
| Response Time (T90) | ≤60 s |
| Zero Drift | ≤±5% FS (per 8 h) |
| Span Drift | ≤±1% FS (per 8 h) |
| Linearity Error | ≤±2% FS |
| Certifications | ATEX II 1G Ex ia IIC T4 Ga, UL 913 Class I Div 1 Groups A–D, CSA C22.2 No. 152, IECEx, CMC |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PHS-3C |
| Pricing | Available Upon Request |
| Display | 3½-digit LED |
| Temperature Compensation | Manual (0–60 °C) |
| Calibration | One-point or Two-point |
| Compatible Electrode | E-201-C pH Combination Electrode |
| Accuracy Class | 0.01 |
| pH Range | 0.00–14.00 pH |
| mV Range | ±0.00–1800.00 mV |
| pH Resolution | 0.01 pH |
| mV Resolution | 1 mV |
| pH Basic Error | ±0.01 pH ±1 digit |
| mV Basic Error | ±1 mV ±1 digit |
| Input Impedance | ≥1×10¹² Ω |
| Drift | ≤±0.01 pH ±1 digit / 3 h |
| Sample Temperature Range | 5–60 °C |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XP-3110 |
| Price Range | USD 700–1,400 |
| Instrument Type | Portable |
| Detectable Gases | Combustible Gases (e.g., Methane, Propane, Butane, LPG, Town Gas) |
| Response Time | ≤45 s (T90) |
| Measurement Accuracy | ±5% of Full Scale |
| Measurement Ranges | 0–10% LEL and 0–100% LEL (auto-ranging) |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AWA5633A |
| Pricing | Available Upon Request |
| Noise Floor | <30 dB(A) |
| Max. Measurable Level | 130 dB |
| Microphone | 12.7 mm (½″) Electret Condenser |
| Frequency Range | 20 Hz – 8 kHz |
| Frequency Weightings | A, C |
| Detection | Digital True RMS, Dynamic Range ≥60 dB |
| Time Weightings | Fast (F), Slow (S) |
| Range Selection | Manual, 3 ranges |
| Display | 3½-digit LCD, update rate: 1 reading/sec |
| Output | AC output (rms) |
| Calibration | Compatible with standard acoustic calibrators (e.g., 94 dB/114 dB @ 1 kHz) |
| Power | 4×AA (R6) alkaline batteries, ~20 h continuous operation |
| Operating Environment | 0–40 °C, RH <85% (non-condensing) |
| Dimensions (L×W×H) | 210×75×32 mm |
| Mass | 300 g (including batteries) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HOBO U30 |
| Pricing | Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DUSTMATE |
| Pricing | Available Upon Request |
| Capacity | 220 g |
|---|---|
| Readability | 0.1 mg |
| Pan Size | 80 mm diameter |
| Clear Height under Draft Shield | 240 mm |
| Dimensions (W×D×H) | 350 × 215 × 340 mm |
| Net Weight | 7.5 kg |
| Power Supply | 220 V, 50 Hz |
| Display | Backlit LCD (120 × 55 mm) |
| Interface | RS232 standard port |
| Calibration | Internal motorized auto-calibration with external calibration weight |
| Environmental Protection | Four-sided antistatic coated glass draft shield |
| Weighing Units | g, oz, ct |
| Sensor Technology | Electromagnetic force compensation (EMFC) principle |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | JS94H2M Zeta |
| Price Range | USD 7,000–14,000 |
| Zeta Potential Range | ±3000 mV |
| pH Range | 0–14 |
| Operating Temperature Range | 5–35 °C |
| pH Resolution | 0.1 |
| Temperature Resolution | 0.1 °C |
| Accuracy | ≤5% |
| Repeatability | ≤5% |
| Particle Size Compatibility | 0.5–20 µm |
| Solvent Compatibility | Aqueous and non-aqueous dispersions |
| Optical System | Semiconductor-based blue/green LED illumination (low-power, <100 µW), 1200× digital magnification |
| Electrophoretic Cell | Integrated Ag/Pt/Ti electrodes in 0.5 cm-thick borosilicate glass cuvette |
| Voltage Control | Adjustable DC bias with polarity reversal (0.30–1.20 s interval) |
| Data Acquisition | Real-time temperature compensation |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JK99D |
| Pricing | Upon Request |
| Measurement Range | 0–500 mN/m |
| Sensitivity | 0.05 mN/m |
| Accuracy | ±0.1 mN/m |
| Resolution | <0.05 mN/m |
| Methods | Du Noüy Ring & Wilhelmy Plate |
| Ring Method Cycle Time | 150–200 s |
| Plate Method Cycle Time | 1–5 s |
| Power Supply | AC 220 ±5 V, <150 W |
| Temperature Control Precision | ±0.1 °C (with optional thermostatic platform) |
| Humidity Range | 30–85% RH |
| Zeroing | Hardware & Software One-Touch Auto-Zero |
| Calibration | Integrated standard weight kit |
| Compliance | ASTM D971, ISO 6295, ISO 1409, USP <721>, GB/T 6541 |
| Brand | G-WON |
|---|---|
| Origin | South Korea |
| Model | GMK-303RS |
| Measurement Principle | Capacitance Dielectric Method |
| Sample Types | Rice (8.3–26.0%), Paddy (8.5–40.0%), Soybean (8.5–21.5%), Red Bean (12.5–19.7%), Barley (8.3–35.0%), Wheat (8.5–35.0%), Corn/Maize (8.7–22.8%) |
| Accuracy | ±0.5% w.b. |
| Display | Digital LCD with Automatic Temperature Compensation |
| Power | 4 × 1.5 V AA batteries (low-battery indicator) |
| Dimensions | 164 × 94 × 40 mm |
| Weight | ~1.2 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | YXQ-LS-50A |
| Quotation | Available Upon Request |
| Chamber Capacity | 50 L |
| Max Operating Temperature | 135 °C |
| Max Operating Pressure | 0.22 MPa |
| Heating Power | 2.7 kW |
| Voltage/Frequency | 220 V ±10 % / 50 Hz ±2 % |
| External Dimensions (W×D×H) | 525 × 440 × 1080 mm |
| Internal Chamber Diameter × Height | Ø300 × 680 mm |
| Basket Dimensions (Ø × H × Qty) | Ø280 × 210 mm × 3 pcs |
| Control Modes | Standard exhaust / Pulse exhaust / No exhaust |
| Safety Compliance | Meets PRC Pressure Vessel Safety Technical Supervision Regulations Art. 49 |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AWA6218C |
| Pricing | Upon Request |
| Accuracy Class | Type 2 per IEC 61672:2002 & GB/T 17181 |
| Microphone | 1/2″ Pre-polarized Condenser, Sensitivity ≈ 40 mV/Pa |
| Frequency Range | 20 Hz – 12.5 kHz |
| Measurement Range | 35 dB – 130 dB (optional extended: 27 dB – 120 dB) |
| Frequency Weighting | A-weighting only |
| Time Weighting | Fast (F), Slow (S) |
| Detector | Digital True RMS, Crest Factor ≥ 3 |
| Operating Modes | Single-shot, 24-hour Automated Logging |
| Measured Metrics | L<sub>p</sub>, L<sub>inst</sub>, L<sub>5</sub>, L<sub>10</sub>, L<sub>50</sub>, L<sub>90</sub>, L<sub>95</sub>, E (Sound Exposure), L<sub>eq</sub>, L<sub>max</sub>, L<sub>min</sub> |
| Integration Times | Manual, 10 s, 1 min, 5 min, 10 min, 20 min, 1 h, 2 h, 4 h, 8 h, 24 h |
| Real-time Clock | Battery-backed calendar clock with persistent timekeeping during power loss |
| Data Storage | Up to 120 measurement sets with statistical distribution graphs, non-volatile Flash RAM |
| Interface | RS-232 serial port for printer or PC communication |
| Optional Filters | Compatible with AWA5721 (octave-band) or AWA5722 (1/3-octave-band) external filter sets |
| Printer Support | UP40 thermal micro-printer |
| Power Supply | 4 × AA alkaline batteries (≥48 h operation, <20 mA current draw) |
| Operating Temperature | 0 °C to 40 °C (extended range: –10 °C to +50 °C, optional) |
| Dimensions | 220 × 72 × 32 mm |
| Mass | ≈ 0.3 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | P-5L2C |
| Price | Upon Request |
| Detection Principle | Light Scattering (Nephelometry) |
| Sensitivity | 0.01 mg/m³ |
| Measurement Range | 0.01–100 mg/m³ |
| Sampling Duration Options | 0.1, 1, 3, 5, 10, 15 min + manual mode |
| Repeatability Error | ±2% |
| Accuracy | ±10% |
| Display | 4-digit LCD showing CPM and mass concentration (mg/m³) |
| Data Output | RS232 serial interface for PC connection or dedicated thermal printer |
| Data Storage | 99 measurement records |
| Environmental Operating Temperature | 0–40 °C |
| Power Supply | NiMH ×9 rechargeable battery (12 h continuous operation) |
| Dimensions | 202 × 85 × 168 mm |
| Weight | 2.4 kg |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BZG30 |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DLY-4 |
| Pricing | Available Upon Request |
| Ion Concentration Range | 1–1.999×10⁹ ions/cm³ |
| Resolution | 1 ion/cm³ |
| Ion Mobility Ranges | 1.0 / 0.4 / 0.15 cm²/(V·s) (3-step selection) |
| Sampling Airflow Velocity | 180 cm/s |
| Response Time Constant | ~15 s |
| Accuracy | ±10% for ion concentration and ion mobility |
| Power Supply | DC 12 V or AC 220 V |
| Operating Environment | –0 to +40 °C, ≤90% RH (short-term operation permitted above 90% RH) |
| Compliance | GB/T 18809–2002 |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | YSD130(A) |
| Price Range | USD 140–280 |
| Frequency Range | 31.5 Hz – 8 kHz |
| Measurement Range | 30 dB – 130 dB |
| Accuracy | ±1.4 dB |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | JC2000X |
| Pricing | Available Upon Request |
| Origin | United Kingdom |
|---|---|
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Model | 715 |
| Pricing | Upon Request |
| Weight | 1.2 kg |
| Dimensions | 280 × 230 × 130 mm |
| Enclosure Rating | IP54 (main unit), IP68 (probe) |
| Cable Diameter | 5 mm |
| Standard Cable Length | 10 m (max. 15 m) |
| Operating Temperature | −20–60 °C (unit), 0–40 °C (probe) |
| Storage Temperature | −20–60 °C (unit), 0–40 °C (probe) |
| Power Supply | 9 V PP9 battery (typical lifespan: 3 months) |
| Response Time | 0.5 s |
| Interface Detection Accuracy | ±1 cm |
| Resolution | 1 cm (marked at 1 m intervals) |
| Measurement Principle | Near-infrared light scattering (960 nm) |
| Probe Options | IR100 (0–200 mg/L, 100 mm sensing gap), IR40 (0–1,500 mg/L, 40 mm), IR15 (0–10,000 mg/L, 15 mm), IR8 (0–30,000 mg/L, 8 mm) |
| Output | Audible tone (short in water, long in sludge), LED indicator, no analog/digital output |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | BY-2003P |
| Pricing | Upon Request |
| Range | 80–110 kPa |
| Accuracy | ±0.5% FS |
| Display Resolution | 0.1 kPa |
| Operating Temperature | 5–50 °C |
| Power Supply | 9 V alkaline battery |
| Dimensions | 140 × 76 × 31 mm |
| Display | 3½-digit LCD |
| Weight | ~190 g (including battery) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Orion Star A113 |
| Pricing | Upon Request |
Show next