Empowering Scientific Discovery

Boxun BXQ-250 Full-Range Biochemical Incubator

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Boxun
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Region of Origin Domestic (China)
Model BXQ-250
Price Range USD 1,400 – 2,800
Temperature Range 0–80 °C
Resolution 0.1 °C
Temperature Uniformity ±1 °C (at 25 °C)
Temperature Fluctuation ±0.5 °C (at 25 °C)
Rated Power Input 1000 W
Chamber Volume 250 L
Interior Dimensions (mm) 650 × 740 × 1726
Standard Shelves 4 (max 7)
Shelf Load Capacity 15 kg per shelf
Timer Range 0–9999 min / 0–9999 h (switchable)
Calendar-Based Programming 30 segments × 99 cycles
USB Interface 1 × standard type-A
Communication Ports 2 × RS-485
Observation Window Full-view tempered glass inner door
Cooling System Inverter-driven refrigeration with eco-friendly refrigerant (R134a or equivalent)
Noise Level >50% reduction vs. conventional compressors
Safety Protections Independent over-temperature cutoff, door-open alarm, sensor fault detection, compressor overheat protection, overload & earth-leakage protection

Overview

The Boxun BXQ-250 Full-Range Biochemical Incubator is an engineered environmental control system designed for precise, stable, and traceable temperature regulation across a broad operational range—from refrigerated (0 °C) to elevated (80 °C) conditions. Unlike standard microbiological incubators limited to 37 °C or general-purpose ovens, the BXQ-250 employs a variable-frequency refrigeration architecture that enables continuous, frost-free operation across its entire span—eliminating manual defrost cycles and thermal instability associated with on/off compressors. Its core function is to maintain consistent thermal environments for sensitive biological processes including BOD incubation, microbial culture propagation, fungal growth studies, plant tissue development, and long-term sample preservation. The unit complies with fundamental design principles outlined in ISO 13408-1 (sterile processing), ASTM D5210 (BOD testing), and USP (environmental control for stability studies), supporting GLP-compliant workflows in regulated laboratories.

Key Features

  • Intelligent BRIGHT I control system with adaptive parameter compensation—dynamically adjusts PID tuning based on ambient temperature drift and load changes.
  • 5-inch high-resolution LCD touchscreen interface with multi-level password protection (administrator, operator, technician tiers) to enforce role-based access control.
  • Embedded data logger retaining ≥5 years of timestamped temperature records internally—no external SD card required; supports tamper-proof export via USB in read-only .csv format for audit trail compliance.
  • Event logging with real-time timestamps for all critical actions: parameter modifications, alarm triggers (e.g., over-temperature, door open, sensor failure), and system faults—exportable via USB for root-cause analysis.
  • Six-stage adjustable air circulation speed—enabling optimization for low-volatility cultures (e.g., anaerobic bacteria) or high-moisture specimens (e.g., algal suspensions) without inducing desiccation.
  • Dual-door structure with full-view tempered inner glass door—minimizes thermal disturbance during observation and eliminates condensation interference with visual monitoring.
  • Inverter-driven refrigeration system using environmentally compliant refrigerant—ensures energy efficiency (IEER ≥ 3.2), quiet operation (<45 dB[A]), and uniform cooling performance at all setpoints.
  • Integrated safety redundancies: independent mechanical over-temperature cut-off, dual thermal sensors, earth-leakage circuit interrupter (ELCI), and compressor thermal shutdown—validated per IEC 61010-1.

Sample Compatibility & Compliance

The BXQ-250 accommodates diverse biological and biochemical sample formats—including Petri dishes, culture flasks (up to 2 L), multi-well plates, glass vials, and botanical growth trays—within its 250 L chamber (650 × 740 × 1726 mm internal dimensions). Its stainless-steel, radius-cornered interior minimizes microbial harborage and simplifies cleaning validation per ISO 14644-1 Class 8 requirements. Two 30 mm-diameter pass-through ports (left/right sidewalls) allow calibrated probe insertion for IQ/OQ/PQ verification without compromising chamber integrity. A built-in 220 V AC waterproof socket (IPX4 rated) permits in-chamber integration of auxiliary devices such as pH meters or dissolved oxygen sensors. The unit meets electromagnetic compatibility (EMC) standards per CISPR 11 Group 1, Class B and carries CE marking under the EU Machinery Directive 2006/42/EC.

Software & Data Management

Data integrity is maintained through embedded firmware with non-volatile memory retention and cryptographic checksums for logged entries. All exported files include digital signatures verifying immutability—supporting FDA 21 CFR Part 11 compliance when paired with validated user authentication protocols. Optional integration with Boxun’s remote monitoring platform (via RS-485 Modbus RTU) enables centralized fleet management, real-time alerting (SMS/email), and historical trend visualization. Audit trails capture user ID, timestamp, action type, and pre-/post-value changes—fully aligned with ALCOA+ principles (Attributable, Legible, Contemporaneous, Original, Accurate, Complete, Consistent, Enduring, Available).

Applications

  • Biochemical Oxygen Demand (BOD5) incubation per APHA Standard Methods 5210B and ISO 5815-1.
  • Microbial enumeration (total viable count, coliforms, yeasts/molds) under ISO 4833-1, ISO 21528-2, and AOAC 977.27.
  • Plant seed germination and callus induction studies requiring precise thermo-photoperiod coordination.
  • Enzyme activity assays and protein stability profiling across thermal gradients.
  • Long-term storage of reference standards, clinical isolates, and cryopreserved cell stocks prior to freezing.
  • Environmental simulation for ecotoxicology testing (e.g., OECD 201, 210) under controlled thermal regimes.

FAQ

Does the BXQ-250 support GLP-compliant data archiving?
Yes—the internal logger stores ≥5 years of temperature history with millisecond timestamps; USB exports are write-protected and include hash-verified file integrity checks.
What validation support is provided for IQ/OQ/PQ protocols?
Two 30 mm calibrated access ports, NIST-traceable sensor calibration certificates (optional), and a documented risk assessment template for thermal mapping are included.
Can the incubator operate continuously at 4 °C or 65 °C without defrost interruption?
Yes—its inverter-driven refrigeration system maintains stable operation across the full 0–80 °C range without frost accumulation or cycling-induced fluctuations.
Is the RS-485 interface compatible with LabVIEW or SCADA systems?
Yes—Modbus RTU protocol implementation allows seamless integration with third-party supervisory control software using standard function codes (03h, 06h, 10h).
What maintenance intervals are recommended for optimal performance?
Condenser cleaning every 6 months via the front-access service panel; annual verification of temperature uniformity and sensor accuracy per ISO/IEC 17025 guidelines.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0