Empowering Scientific Discovery

Yoke YKM-T1 8th-Generation Single-Parameter Water Quality Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Yoke
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Product Category Domestic
Model YKM-T1
Price Range USD 4,200 – 7,000 (FOB Shanghai)
Instrument Type Laboratory Water Quality Analyzer
Measured Parameters (select one per assay) Ammonia-Nitrogen (NH₃-N), Chemical Oxygen Demand (COD), Total Phosphorus (TP), Total Nitrogen (TN)
Display 7-inch TFT LCD (1024 × 600)
Optical System Single-beam CT-type dual-optical-path ratio system
Detection Method UV-Vis spectrophotometry (220–900 nm)
Wavelength Accuracy ±1 nm
Photometric Accuracy ±0.001 A (at 0.5 A, 546 nm)
Stray Light <0.05% T at 220 nm
Detection Range (typical) COD (High: 15–5000 mg/L
Low 5–160 mg/L), NH₃-N (0.01–100 mg/L), TP (0.01–80 mg/L), TN (0.002–20 mg/L)
Chloride Interference Tolerance ≤1000 mg/L Cl⁻ (standard)
Photometric Precision ≤±2% RSD (n=6, mid-range standard)
Absorbance Stability ±0.001 A / 10 min
Measurement Time 10–20 min per sample (including reagent reaction and optical readout)
Data Storage 5 million test records + 500 user-defined calibration curves (linear, segmented, single-point)
Connectivity RS-232C (for thermal/impact printers), USB Device (PC link), USB Host (U-disk support), Bluetooth 5.0 (optional)
Storage Media Internal 16 GB eMMC + external U-disk (FAT32/exFAT)
File Export Formats .csv, .qua, .txt, .bmp
Power Supply AC 100–240 V, 50/60 Hz
Dimensions 350 × 280 × 180 mm
Weight 5.2 kg

Overview

The Yoke YKM-T1 is an 8th-generation laboratory-grade single-parameter water quality analyzer engineered for high-reproducibility spectrophotometric quantification of key regulatory analytes in environmental, municipal, and industrial water samples. It employs a CT-type dual-optical-path ratio detection architecture—combining a stable reference beam with a sample beam—to actively compensate for source intensity drift, cuvette imperfections, and ambient light fluctuations. This design enables robust absorbance measurement across the full UV-Vis range (220–900 nm), supporting standardized methods for ammonia-nitrogen (NH₃-N), chemical oxygen demand (COD), total phosphorus (TP), and total nitrogen (TN). Each assay is conducted using pre-formulated, NIST-traceable liquid reagents that eliminate manual powder dissolution, minimize operator error, and ensure compliance with EPA Method 351.2 (TN), ISO 11908:2015 (COD), ISO 7150-1:1984 (NH₃-N), and ISO 6878:2004 (TP). The instrument operates under a fixed-wavelength or auto-wavelength-selection protocol depending on the selected parameter, delivering results traceable to national metrological standards.

Key Features

  • 7-inch high-resolution TFT-LCD (1024 × 600) with intuitive icon-driven menu navigation and tactile Omron membrane switches rated for >10⁶ actuations
  • ARM11-based embedded computing platform enabling real-time data processing, onboard curve fitting, and secure local storage of 5 million test records
  • Suspended optical assembly mounted on reinforced aluminum baseplate—mechanically isolating photometric path from thermal expansion and vibration-induced misalignment
  • Dual-layer chassis architecture physically separating optical components (light source, monochromator, detector) from digital signal processing circuitry to suppress electromagnetic interference
  • Patented optoelectronic transduction module achieving signal-to-noise ratio (SNR) >3.5 × 10⁴:1, ensuring low-drift baseline stability (±0.001 A/10 min)
  • Modular hardware expansion: optional 8-position rotating cuvette carousel (patent-pending centering mechanism) and integrated peristaltic autosampler for unattended batch analysis
  • Multi-interface connectivity including RS-232C (printer-ready), USB Device (PC synchronization), USB Host (direct U-disk export), and Bluetooth 5.0 (wireless data telemetry)

Sample Compatibility & Compliance

The YKM-T1 accepts standard 10 mm, 20 mm, or 30 mm rectangular quartz or optical-grade plastic cuvettes (including optional 4-position or 8-position carousels). It complies with GLP documentation requirements through built-in audit trail functionality: all calibrations, measurements, and method changes are timestamped, user-ID logged, and stored immutably in internal memory. Data integrity meets FDA 21 CFR Part 11 criteria when paired with optional password-protected user roles and electronic signature modules. Reagent kits are supplied with CoA (Certificate of Analysis), shelf-life validation, and lot-specific uncertainty budgets aligned with ISO/IEC 17025 calibration practices. Chloride interference mitigation is validated per ASTM D1253-22 for COD and ISO 11908 Annex B for TN, supporting accurate analysis in brackish wastewater, landfill leachate, and coastal influent streams.

Software & Data Management

Data files are natively exported in open, non-proprietary formats—including CSV (comma-separated values), TXT (ASCII), BMP (raster image), and QUA (Yoke’s structured spectral archive format)—requiring no vendor-specific software for viewing or post-processing. Internal 16 GB eMMC storage retains full measurement history, including raw absorbance spectra, kinetic reaction traces, calibration coefficients, and operator annotations. USB HOST support allows direct drag-and-drop transfer to Windows/macOS/Linux systems; exported CSV files integrate seamlessly into LIMS platforms (e.g., LabWare, Thermo Fisher SampleManager) or statistical tools (JMP, Minitab, Python pandas). Firmware updates are delivered via signed .bin packages verified by SHA-256 hash, ensuring secure field upgrades without third-party dependency.

Applications

  • Regulatory compliance testing for municipal wastewater treatment plants (WWTPs) under EU Urban Wastewater Treatment Directive (91/271/EEC) and US Clean Water Act NPDES permits
  • Process control monitoring in industrial effluent streams (e.g., food & beverage, pharmaceutical, textile manufacturing)
  • Environmental monitoring of surface water bodies (rivers, lakes, reservoirs) per national water quality standards (e.g., China’s GB 3838-2002, US EPA Region 10 protocols)
  • Research-grade nutrient profiling in limnological and hydrological studies requiring trace-level TN and TP resolution
  • Educational laboratories performing AP Environmental Science or undergraduate analytical chemistry curricula with full method transparency and reproducibility

FAQ

Is the YKM-T1 compliant with ISO/IEC 17025 for accredited testing laboratories?
Yes—the instrument supports documented calibration verification, traceable reference standards, and full data audit trails required for ISO/IEC 17025:2017 Clause 7.7. Optional calibration certificate issuance by CNAS-accredited labs is available upon request.
Can the YKM-T1 perform simultaneous multi-parameter analysis?
No—it is a single-parameter platform by design to maximize precision, reduce cross-contamination risk, and simplify regulatory validation. For multi-analyte workflows, sequential assays using dedicated reagent sets are recommended.
What is the expected lifetime of the deuterium and tungsten lamps?
Deuterium lamp: ≥1,500 hours; tungsten lamp: ≥5,000 hours. Both are user-replaceable with factory-aligned collimation fixtures to maintain optical path integrity.
Does the instrument support remote diagnostics or cloud-based data backup?
Not natively—but Bluetooth 5.0 output enables integration with edge gateways for MQTT-based telemetry to private cloud infrastructures (e.g., AWS IoT Core, Azure IoT Hub) via custom middleware.
Are reagent kits certified for use in official regulatory submissions?
Yes—each lot undergoes batch-specific validation against CRM materials (NIST SRM 2193a for COD, BAM-NH3-01 for ammonia-N) and includes full uncertainty budget documentation compliant with ISO/IEC Guide 98-3 (GUM).

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0