Empowering Scientific Discovery

TimePower TP-140 Online Acid/Base Concentration Monitor

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand TimePower
Origin Beijing, China
Manufacturer Type Direct Manufacturer
Instrument Type Benchtop
Parameter Capability Multi-parameter
pH Measurement Range 0.0–14.0 pH
Resolution ±0.1 pH
Accuracy ±0.1 pH
Calibration Standard Compatibility NIST-traceable (China Edition) / USA NIST-equivalent (International Edition)
Display 128×64 Dot Matrix LCD (Chinese UI)
Analog Outputs Selectable 0–10 mA, 0–20 mA, or 4–20 mA
Signal Acquisition 24-bit A/D Conversion
Data Storage Cyclic Memory with Auto-Overflow Management
Electrode Construction Corrosion-Resistant Electrochemical Sensor

Overview

The TimePower TP-140 Online Acid/Base Concentration Monitor is a benchtop electrochemical analyzer engineered for continuous, real-time quantification of hydrogen ion activity in aqueous process streams. Operating on the fundamental principle of potentiometric pH measurement—where the potential difference between a pH-sensitive glass electrode and a stable reference electrode is converted into a logarithmic pH value—the TP-140 delivers stable, reproducible readings across the full operational range of 0.0 to 14.0 pH. Designed specifically for integration into industrial control loops, it serves as a primary analytical node in critical applications where acid or base concentration directly impacts reaction kinetics, neutralization efficiency, corrosion mitigation, or product quality consistency. Its architecture adheres to IEC 61000-6-2/6-4 immunity and emission standards, ensuring reliable operation in electrically noisy plant environments typical of power generation, chemical synthesis, metallurgical leaching, food processing, and pharmaceutical manufacturing.

Key Features

  • Corrosion-resistant, integrated pH electrode assembly optimized for long-term stability in aggressive acidic or alkaline media—including sulfuric, hydrochloric, sodium hydroxide, and ammonia solutions.
  • 24-bit high-resolution analog-to-digital conversion circuitry ensures minimal quantization error and enhanced signal fidelity under dynamic process conditions.
  • Configurable analog current outputs (0–10 mA, 0–20 mA, or 4–20 mA) support seamless interface with DCS, PLC, and SCADA systems without external signal conditioning.
  • Built-in cyclic data logger retains up to 30 days of timestamped pH values at user-defined intervals; memory management automatically overwrites oldest entries upon capacity saturation.
  • 128×64 monochrome LCD with native Chinese character rendering provides intuitive status visualization, real-time measurement display, calibration prompts, and diagnostic alerts—reducing operator training overhead in domestic installations.
  • Compliant with ISO/IEC 17025 traceability requirements when calibrated using NIST-traceable buffer solutions (China Edition) or USA NIST-equivalent certified standards (International Edition).

Sample Compatibility & Compliance

The TP-140 is validated for use with homogeneous aqueous solutions exhibiting conductivity ≥50 µS/cm and temperature stability within 0–50 °C. It is not intended for non-aqueous solvents, highly viscous slurries, or samples containing suspended solids >50 mg/L without pre-filtration. The instrument meets CE marking requirements per Directive 2014/30/EU (EMC) and 2014/35/EU (LVD). For regulated industries, its calibration documentation, output linearity verification logs, and manual calibration audit trail support compliance with FDA 21 CFR Part 11 (when paired with time-stamped electronic records), ISO 9001:2015 clause 7.1.5, and ASTM D1293–22 (Standard Test Method for pH of Water).

Software & Data Management

While the TP-140 operates as a standalone hardware unit without embedded PC software, its analog outputs are fully compatible with third-party historian platforms such as Siemens Desigo CC, Honeywell Experion PKS, and Emerson DeltaV. Raw output signals may be logged, trended, and alarm-processed via standard 4–20 mA input modules. Calibration events—including date/time stamp, buffer ID, slope/mV offset, and asymmetry potential—are stored in non-volatile memory and retrievable via front-panel navigation. All calibration data conforms to GLP-aligned record-keeping practices, enabling retrospective verification during internal audits or regulatory inspections.

Applications

  • Boiler feedwater and condensate pH monitoring in thermal power plants to prevent caustic embrittlement and acid corrosion.
  • Neutralization tank control in wastewater treatment facilities, ensuring effluent compliance with local discharge limits (e.g., EPA NPDES requirements).
  • In-line titration endpoint detection during batch synthesis of active pharmaceutical ingredients (APIs), supporting QbD-based process validation.
  • Acid pickling bath concentration tracking in steel mills, minimizing overuse of HCl/H₂SO₄ and reducing hazardous waste generation.
  • pH stabilization in fermentation bioreactors for dairy, beverage, and probiotic production—critical for microbial viability and metabolite yield.

FAQ

What calibration standards are supported?
The TP-140 accepts both China-specific NIST-traceable buffers (pH 4.01, 6.86, 9.18 at 25 °C) and internationally recognized USA NIST-equivalent standards. Calibration certificate traceability must be verified prior to use in regulated environments.
Can the device operate continuously in high-temperature process lines?
The TP-140 is rated for ambient operating temperatures of 0–50 °C. For inline installation in hot streams (>50 °C), a cooled sample bypass loop with thermostatic regulation is required to maintain sensor integrity and measurement accuracy.
Is remote configuration or firmware update possible?
No. Configuration (e.g., output range, damping factor, display language) is performed exclusively via front-panel keypad. Firmware is factory-programmed and not field-upgradable.
Does the instrument comply with explosion-proof requirements?
The TP-140 is not intrinsically safe or explosion-proof certified. It must be installed in non-hazardous classified areas per NEC Class I, Division 2 or ATEX Zone 2 guidelines.
How often should calibration be performed in continuous operation?
Daily calibration is recommended for critical processes; weekly calibration is acceptable for stable, low-drift applications. Frequency must be justified and documented per site-specific SOPs aligned with ISO/IEC 17025 or GMP Annex 11.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0