Empowering Scientific Discovery

TimePower TP653 Coulometric Karl Fischer Moisture Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand TimePower
Origin Beijing, China
Manufacturer Type Direct Manufacturer
Country of Origin China
Model TP653
Pricing Upon Request

Overview

The TimePower TP653 is a high-precision coulometric Karl Fischer moisture analyzer engineered for trace water quantification in liquids, oils, solvents, and chemically stable samples. Unlike volumetric titration-based systems, the TP653 employs the electrochemical principle of coulometric Karl Fischer titration—where water reacts stoichiometrically with iodine generated *in situ* via controlled electrolysis of iodide ions in the anolyte solution. This method conforms to ISO 8533, ASTM D6304, ASTM D4928, and USP , and is validated for compliance with GLP and GMP laboratory practices. The instrument delivers sub-ppm (µg H₂O) detection capability with high reproducibility (RSD < 0.3% at 100 µg water), making it suitable for quality control in petrochemicals, pharmaceuticals, lubricants, and fine chemical manufacturing where regulatory-grade moisture data are required.

Key Features

  • Coulometric detection mode only—no manual reagent standardization or titer calibration required between analyses
  • Integrated dual-chamber electrolytic cell with platinum electrodes and diaphragm-separated anode/cathode compartments for stable iodine generation
  • Programmable magnetic stirring speed (100–1200 rpm) with real-time feedback control to ensure homogeneous sample dispersion and rapid reaction kinetics
  • Automated reagent dispensing and waste removal system—eliminates manual solvent exchange and reduces operator intervention
  • Onboard microprocessor with 32-bit ARM core, supporting up to 100 method protocols with customizable endpoint criteria (drift-based or time-limited)
  • USB and RS-232 interfaces for external data logging; optional Ethernet module available for LIMS integration

Sample Compatibility & Compliance

The TP653 is optimized for liquid-phase analysis of hydrocarbons (e.g., transformer oil, jet fuel, diesel), polar solvents (acetonitrile, methanol, THF), and non-aqueous pharmaceutical excipients. It accommodates samples with water content ranging from 1 µg to 100 mg H₂O per injection. Samples must be free of aldehydes, ketones, strong oxidizers, or reactive amines that interfere with the I₂/H₂O stoichiometry. The analyzer meets ISO/IEC 17025 technical requirements for testing laboratories and supports 21 CFR Part 11-compliant audit trails when paired with TimePower’s certified software suite. All calibration and performance verification procedures align with ASTM E203 and ISO 760 guidelines.

Software & Data Management

The TP653 operates with TimePower MoistureSuite™ v3.2—a Windows-based application enabling method development, sequence programming, raw data export (CSV, XML), and electronic signature workflows. Each analysis record includes timestamped metadata: ambient temperature/humidity, cell voltage profile, electrolysis charge (coulombs), drift value pre/post-titration, and pass/fail status against user-defined acceptance criteria. Audit logs capture all user actions—including method edits, calibration events, and result modifications—with immutable timestamps. Data files are SHA-256 hashed and stored in encrypted SQLite databases compliant with ALCOA+ principles (Attributable, Legible, Contemporaneous, Original, Accurate, Complete, Consistent, Enduring, Available).

Applications

  • Petrochemical QC: Quantifying dissolved, emulsified, and suspended water in crude oil fractions, lube base stocks, and aviation turbine fuels per ASTM D6304
  • Pharmaceutical manufacturing: Residual moisture testing of active pharmaceutical ingredients (APIs) and lyophilized products per USP and EP 2.5.12
  • Electrolyte formulation: Water content verification in Li-ion battery electrolytes (e.g., LiPF₆ in EC/DMC), where >20 ppm H₂O triggers HF formation
  • Paint & coating R&D: Monitoring moisture ingress in polyurethane resins and epoxy hardeners to prevent premature gelation
  • Food-grade solvent validation: Ensuring anhydrous conditions for extraction solvents used in natural flavor production

FAQ

What is the fundamental difference between coulometric and volumetric Karl Fischer methods?
Coulometric KF generates iodine electrochemically within the titration cell at a known current, allowing direct calculation of water mass from Faraday’s law. Volumetric KF uses pre-standardized iodine-containing reagent delivered via burette, requiring frequent recalibration due to reagent instability.
Does the TP653 require daily reagent replacement?
No. The coulometric anolyte (typically 5 mL of iodide-rich solvent) remains stable for ≥30 days under sealed, inert conditions and supports >500 injections before replacement.
Can the TP653 analyze solid or viscous samples?
Only after dissolution in compatible KF-compatible solvents (e.g., chloroform, formamide). Direct solid injection is not supported; use of a dedicated oven sampler (optional accessory) is required for volatilizable solids.
Is method validation support provided?
Yes—TimePower supplies IQ/OQ documentation templates, system suitability test protocols, and reference standards traceable to NIST SRM 2890 (water-in-toluene).
How is electrode contamination prevented during long-term operation?
The TP653 features automatic electrode cleaning cycles triggered by elevated cell resistance or abnormal voltage profiles, using pulsed reverse-current regeneration to restore platinum surface activity.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0