Titan SCY-30 30-Gallon (114 L) Flammable Liquid Safety Cabinet
| Brand | Titan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | SCY-30 |
| Price | USD 670 (approx., FOB Shanghai) |
Overview
The Titan SCY-30 is a UL-listed and FM-approved flammable liquid safety cabinet engineered for secure storage of Class I, II, and IIIA flammable and combustible liquids in laboratories, pharmaceutical production areas, chemical handling zones, and industrial maintenance facilities. Designed in strict accordance with NFPA 30 (Flammable and Combustible Liquids Code), OSHA 29 CFR 1910.106, and ANSI Z358.1-compliant ventilation interface standards, the cabinet employs double-walled 18-gauge steel construction with a 1.5-inch air gap for thermal insulation and fire resistance. Its self-closing, three-point latching door system activates automatically at 165 °F (74 °C) via fusible link—ensuring containment integrity during fire exposure. The unit is rated for 10-minute fire resistance per UL 1275 testing protocol and includes leak-proof, 2-inch deep galvanized steel spill containment sump capable of retaining ≥114 L (30 gal) of liquid.
Key Features
- Double-wall 18-gauge cold-rolled steel construction with 1.5-inch insulating air space for structural rigidity and passive fire protection
- Self-closing, three-point latching door with UL-listed fusible link (165 °F activation) and positive latch engagement indicator
- Integrated grounding lug (6 AWG compatible) and conductive door hinge system to prevent static discharge ignition
- Adjustable, powder-coated steel shelves with 50 lb (22.7 kg) uniform load capacity per shelf; rear-mounted shelf supports allow unobstructed sump access
- Perforated rear wall for optional ducted exhaust connection (4-inch diameter port, compliant with ASHRAE 110 and local mechanical code requirements)
- High-visibility hazard warning labels pre-installed per ANSI Z535.4 and GHS pictogram standards (flammability, health hazard, signal word “DANGER”)
Sample Compatibility & Compliance
The SCY-30 is validated for storage of common laboratory and industrial flammables including acetone, ethanol, methanol, toluene, xylene, ethyl acetate, and petroleum ether. It complies with domestic Chinese GB/T 16807–2009 (Fire-resistant cabinets for hazardous materials) and meets international equivalency benchmarks under NFPA 30 Annex B for cabinet performance verification. All internal finishes are corrosion-resistant epoxy-polyester hybrid coated. The cabinet is not intended for storage of oxidizers, organic peroxides, or pyrophoric substances—such materials require dedicated, non-combustible storage per NFPA 430 and USP . Documentation includes factory test reports for door closure force, sump retention volume, and fire-resistance duration.
Software & Data Management
As a passive mechanical safety device, the SCY-30 does not incorporate embedded electronics, firmware, or software interfaces. Its operational integrity relies entirely on mechanical design fidelity and material certification. However, Titan provides digital compliance documentation packages—including PDF-based installation checklists, OSHA/NFPA cross-reference guides, and audit-ready maintenance logs—for integration into institutional EHS management systems (e.g., Intelex, ETQ Reliance, or SAP EHS). Optional QR-coded asset tags support barcode-based inventory tracking within CMMS platforms. All documentation adheres to GLP-aligned record retention principles (minimum 5-year archival requirement).
Applications
- Secure point-of-use storage adjacent to fume hoods or analytical instrument workstations
- Intermediate staging of solvents in QC/QA laboratories under cGMP Annex 1 and ISO/IEC 17025 environments
- Controlled dispensing stations in pilot-scale synthesis labs requiring secondary containment
- On-site storage for maintenance teams handling flammable lubricants, cleaners, or adhesives in manufacturing cleanrooms
- Compliance-driven deployment in university teaching labs subject to state fire marshal inspections and CAP-accredited safety audits
FAQ
Is the SCY-30 certified to UL 1275 or FM 6050?
Yes—the cabinet carries both UL 1275 (Standard for Safety – Flammable Liquid Storage Cabinets) and FM 6050 (Approval Standard for Flammable Liquid Storage Cabinets) certifications, verified via third-party testing at Intertek’s Shanghai laboratory.
Can it be installed without external ventilation?
Yes—per NFPA 30 Section 9.5.2, ducted exhaust is optional; the cabinet is fully functional as a self-contained, non-ducted unit when sump integrity and room ventilation meet minimum ACH requirements.
What is the maximum allowable fill level for the sump?
The sump is engineered to retain 100% of the cabinet’s rated capacity (114 L), but regulatory best practice (OSHA 1910.106(d)(2)) recommends maintaining ≥10% freeboard—i.e., no more than 103 L of liquid stored inside at any time.
Does Titan provide installation support or site surveys?
Titan offers remote technical consultation for layout planning and regulatory alignment; on-site commissioning and fire marshal coordination services are available through authorized regional partners in APAC and EMEA.


