Empowering Scientific Discovery

BINDER KBF PRO 720 Temperature and Humidity Controlled Chamber

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand BINDER
Origin Germany
Manufacturer Type Direct Manufacturer
Origin Category Imported
Model KBF PRO 720
Instrument Type Upright
Temperature Range -20 °C to +100 °C
Humidity Range 10 % RH to 98 % RH
Temperature Uniformity ±0.1 K
Humidity Uniformity ±1 % RH
Interior Dimensions (W × D × H) 1011 mm × 1250 mm × 575 mm

Overview

The BINDER KBF PRO 720 is a high-precision upright environmental test chamber engineered for rigorous long-term stability testing under tightly controlled temperature and humidity conditions. Designed in accordance with DIN 12880 Class 3.3 safety requirements, it employs a dual-loop control architecture combining PID-regulated refrigeration, capacitive humidity sensing, and steam-based humidification to achieve exceptional reproducibility across its full operational envelope—from cryogenic storage at −20 °C to accelerated aging at +100 °C and high-humidity stress testing up to 98 % RH. Its APT.line™ preheating technology ensures uniform thermal distribution throughout the stainless-steel interior cavity, minimizing vertical and horizontal gradients during dynamic ramp-and-soak cycles. The chamber integrates HIT (High Insulation Technology) double-wall construction with R-290 hydrocarbon refrigerant—a low-GWP, non-ozone-depleting alternative compliant with EU F-Gas Regulation (EU No. 517/2014)—and variable-speed scroll compressors that dynamically modulate cooling capacity to reduce energy consumption by up to 40 % versus prior-generation KMF models.

Key Features

  • Stainless-steel interior chamber with electropolished finish and corrosion-resistant door seal—designed for GLP/GMP-compliant operation and extended service life
  • Capacitive humidity sensor with <1 s response time and integrated self-calibration algorithm for traceable RH accuracy
  • Steam humidification system with independent PID control, enabling rapid RH transitions without condensation risk
  • Door heating function prevents moisture accumulation on inner glass, maintaining optical clarity during low-temperature/high-RH operation
  • APT.touch™ programmable controller with multi-segment real-time scheduling, adjustable mounting height (ergonomic design), and status-indicating red triangle LED
  • Two telescopic stainless-steel shelves with load-rated suspension rails; maximum shelf load: 25 kg per shelf
  • Large-diameter cable/port access opening (Ø80 mm) fitted with silicone grommet for external sensor integration or sample monitoring
  • Robust castor base with dual-swivel heavy-duty wheels and front-wheel mechanical locking mechanism for stable floor placement
  • Optical and acoustic over-temperature/over-humidity alarms with independent Class 3.3 safety thermostat (DIN 12880)

Sample Compatibility & Compliance

The KBF PRO 720 accommodates diverse sample geometries and material classes—including polymer films, pharmaceutical dosage forms, electronic assemblies, and biological reference standards—within its 720 L working volume (1011 × 1250 × 575 mm). Its uniformity performance meets ISO 16770:2017 requirements for environmental chambers used in stability testing of medicinal products, and supports ICH Q1A(R3), Q5C, and Q5D protocols when paired with optional APT-COM™ software and validated light modules. The chamber’s validation-ready architecture includes built-in self-diagnostics, event logging with timestamped audit trails, and support for 21 CFR Part 11-compliant electronic signatures via optional APT-COM™ Professional license. All internal surfaces comply with FDA-recommended non-porous, cleanable materials per USP .

Software & Data Management

Data acquisition and remote supervision are enabled through native Ethernet and USB interfaces. Internal data logger stores up to 10,000 measurement points (temperature, humidity, alarm events, setpoint changes) in open CSV format for direct import into LIMS or statistical analysis platforms. BINDER’s APT-COM™ Basic software provides local PC-based monitoring, report generation (PDF/Excel), and basic calibration certificate export. For regulated environments, APT-COM™ Professional adds user role management, electronic signature workflows, change control logs, and automated IQ/OQ documentation templates aligned with ASTM E2500 and GAMP 5 guidance. Optional firmware upgrades enable Modbus TCP integration for centralized facility SCADA systems.

Applications

  • Accelerated stability testing of APIs and finished pharmaceuticals per ICH guidelines
  • Temperature–humidity bias (THB) testing of microelectronic components (JEDEC JESD22-A110)
  • Material degradation studies for polymers, composites, and adhesives (ISO 4892-2, ASTM D4329)
  • Seed germination and plant growth simulation using optional LED lighting modules (PAR-adjustable, 400–700 nm spectrum)
  • Reference standard conditioning prior to gravimetric or spectroscopic analysis
  • Environmental stress screening (ESS) in automotive and aerospace quality assurance workflows
  • Long-term storage validation of diagnostic reagents and biologics under defined温湿度 profiles

FAQ

What is the maximum allowable load weight inside the chamber?
The total internal load must not exceed 40 kg; individual shelf loading is limited to 25 kg per telescopic rail-equipped shelf.
Does the KBF PRO 720 support validation according to GxP requirements?
Yes—its hardware architecture, data integrity features (audit trail, electronic signatures), and APT-COM™ Professional software provide full traceability for IQ/OQ/PQ execution in regulated laboratories.
Can the chamber operate continuously at −20 °C and 10 % RH simultaneously?
Yes—the dual independent control loops and optimized refrigerant circuit ensure stable operation across the entire specified range without dehumidification compromise.
Is the R-290 refrigerant safe for laboratory use?
R-290 is classified as A3 (flammable) under ASHRAE Standard 34, but the KBF PRO 720 incorporates leak detection, automatic shutdown, and forced ventilation interlocks to meet EN 60335-2-89 safety requirements.
How is temperature uniformity verified during qualification?
BINDER provides a 9-point sensor mapping protocol aligned with ISO 16770 Annex B; users may perform qualification using calibrated NIST-traceable probes and documented SOPs.