Empowering Scientific Discovery

BINDER KB ECO 1020 Biochemical Incubator

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand BINDER
Origin Germany
Manufacturer BINDER GmbH
Type Imported
Model KB ECO 1020
Heating Method Air-jacketed
Cooling Method Peltier thermoelectric
Temperature Range 0–70 °C
Temperature Stability at 37 °C ±0.1 °C
Temperature Uniformity at 37 °C ±0.1 °C
Chamber Volume 1020 L
External Dimensions (W×H×D) 1150 × 1930 × 1250 mm

Overview

The BINDER KB ECO 1020 Biochemical Incubator is a high-precision, large-capacity environmental chamber engineered for demanding life science applications requiring stable, reproducible temperature control across a broad operational range—from sub-ambient (down to 0 °C, up to 26 K below ambient) to +70 °C. Its dual-mode thermal regulation system combines air-jacketed heating with solid-state Peltier cooling, eliminating the need for refrigerants while delivering exceptional thermal stability and uniformity. At the core of its performance lies BINDER’s proprietary APT.line™ preheating technology, which ensures rapid, homogeneous chamber conditioning by actively controlling heat distribution in the inner jacket—minimizing thermal gradients during ramp-up and steady-state operation. Designed for continuous, unattended operation in GLP-compliant laboratories, the KB ECO 1020 meets critical requirements for cell culture, enzymatic assays, microbial growth studies, and long-term stability testing where temperature integrity directly impacts experimental validity.

Key Features

  • Air-jacketed heating architecture with independent Peltier-based cooling modules for precise bidirectional temperature control without compressors or CFCs
  • APT.line™ preheating technology with optimized heat dissipation design ensures <±0.1 °C stability and uniformity at 37 °C—validated per DIN 12880 and ISO 1534
  • Stainless steel interior chamber (AISI 304), fully welded and electropolished, with seamless corners for optimal cleanability and corrosion resistance
  • Double-glazed inner door made of safety glass (EN 12150-1) minimizes condensation and improves thermal insulation without compromising visibility
  • Two adjustable stainless steel shelves with load capacity up to 25 kg each; shelf positions configurable in 25-mm increments
  • Integrated condensation management system with programmable dehumidification logic prevents moisture accumulation under low-temperature conditions
  • 30-mm diameter access port with silicone plug enables external sensor integration or tubing passage while maintaining chamber integrity
  • LCD interface with multilingual support displays real-time chamber temperature, setpoint, alarm status, and system diagnostics

Sample Compatibility & Compliance

The KB ECO 1020 accommodates a wide variety of sample formats—including stacked multi-layer flasks, roller bottles, Petri dish stacks, and custom bioreactor vessels—within its 1020 L chamber volume. Its stainless steel construction and smooth internal surfaces comply with ISO 14644-1 Class 5 cleanroom-compatible cleaning protocols. The unit is certified to IEC 61010-1 (Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use) and carries CE marking for the European Economic Area. It supports audit-ready documentation workflows aligned with FDA 21 CFR Part 11 (when used with validated data export procedures), and its temperature validation traceability conforms to ASTM E2874 and EURACHEM/CITAC guidelines. Optional IQ/OQ documentation packages are available for GMP-regulated environments.

Software & Data Management

Internal data logging records temperature readings at user-defined intervals (1 s to 24 h resolution) for up to 30 days, stored in open CSV format accessible via standard USB 2.0 interface—no proprietary software required. The built-in self-diagnostic routine performs automated verification of sensor functionality, heater/cooler actuation, door switch integrity, and fan operation during startup and on-demand. Alarm events—including temperature deviation, door-open duration >60 s, and power interruption—are timestamped and retained in non-volatile memory. For networked environments, optional Ethernet module (KB-ETH) enables integration into centralized lab monitoring systems using Modbus TCP or BACnet/IP protocols.

Applications

  • Long-duration mammalian and insect cell culture under tightly controlled physiological conditions (e.g., 37 °C/5% CO₂ when paired with compatible gas mixing modules)
  • Enzyme kinetics and protein stability profiling across defined thermal gradients
  • Microbial growth curve analysis for pharmaceutical sterility testing (USP , EP 2.6.12)
  • Seed germination and plant tissue culture requiring diurnal temperature cycling
  • Accelerated stability studies per ICH Q1A(R2) guidelines for biologics and small-molecule APIs
  • Environmental simulation for material compatibility testing in medical device R&D

FAQ

What is the lowest temperature achievable relative to ambient?
The KB ECO 1020 can maintain temperatures up to 26 K below ambient, with minimum setpoint limited to 0 °C.
Does the incubator support humidity control?
No—this model is temperature-only; for humidified operation, consider the BINDER KBWF series with integrated steam humidification.
Can temperature data be exported for regulatory submissions?
Yes—CSV-formatted logs are directly readable via USB; validation of data integrity and chain-of-custody requires documented SOPs per ALCOA+ principles.
Is the Peltier cooling system serviceable in the field?
Peltier modules are factory-integrated and not user-replaceable; preventive maintenance includes annual thermal interface compound inspection and airflow path cleaning.
What safety certifications apply to this model?
Complies with IEC 61010-1, EN 61326-1 (EMC), and carries CE, UKCA, and EAC markings; full test reports available upon request.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0