Empowering Scientific Discovery

JingHong DHG-9076A & DHG-9076Y Forced-Air Laboratory Drying Oven

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand JingHong
Origin Shanghai, China
Model DHG-9076A, DHG-9076Y
Temperature Range Ambient +10°C to 300°C
Temperature Uniformity ±1°C
Temperature Resolution 0.1°C
Chamber Dimensions (W×D×H) 400×400×450 mm
External Dimensions (W×D×H) 565×630×805 mm
Inner Chamber Material Stainless Steel (SUS304)
Heating Method Forced-Air Convection
Operating Ambient Temperature 5–40°C
Instrument Type High-Temperature Forced-Air Oven

Overview

The JingHong DHG-9076A and DHG-9076Y are precision-engineered forced-air laboratory drying ovens designed for consistent thermal processing in research, quality control, and industrial testing environments. These models operate on the principle of uniform convective heat transfer, utilizing a low-noise centrifugal blower and optimized internal airflow channels to ensure minimal temperature gradients across the entire working chamber. Engineered for reliability under continuous operation, the ovens maintain stable setpoints within ±1°C across the full operating range of ambient +10°C to 300°C — a specification validated per ISO 17025-aligned thermal mapping protocols. The stainless steel (SUS304) interior chamber resists corrosion from solvents, moisture, and routine cleaning agents, supporting long-term dimensional stability and compliance with GLP documentation requirements for equipment qualification (IQ/OQ/PQ).

Key Features

  • Microprocessor-based PID temperature controller with dual digital display (setpoint and real-time chamber temperature), offering intuitive parameter entry and visual feedback.
  • Self-tuning auto-adjustment algorithm ensures optimal response to load changes and minimizes overshoot during ramp-up or recovery phases.
  • Adjustable power suppression function enables fine-grained energy modulation — critical for thermally sensitive samples or when operating near maximum temperature limits.
  • Programmable timer (up to 9999 minutes) supports unattended operation with automatic shutdown, enhancing laboratory workflow efficiency and safety compliance.
  • Robust forced-air convection system delivers ≤±1°C temperature uniformity (measured at 9 points per IEC 60068-3-5) throughout the 400 × 400 × 450 mm stainless steel chamber.
  • Front-access door with high-efficiency silicone gasket and double-layer tempered glass window provides thermal insulation while enabling visual process monitoring without opening.

Sample Compatibility & Compliance

The DHG-9076A/Y accommodates a broad spectrum of sample types including polymer films, pharmaceutical excipients, ceramic precursors, metal oxide powders, biological tissue specimens (post-fixation), and analytical reference standards. Its design conforms to key international safety and performance benchmarks: EN 61010-1 (Electrical Safety for Laboratory Equipment), IEC 60529 (IP20 ingress protection), and ASTM E145-22 (Standard Specification for Gravity-Convection and Forced-Ventilation Ovens). While not certified for Class I Division 1 hazardous locations, it meets general-purpose laboratory classification under NFPA 45 and EU Directive 2014/34/EU for non-explosive atmospheres. The stainless steel chamber complies with USP material compatibility guidelines for pharmaceutical drying applications.

Software & Data Management

These ovens support optional RS485 communication interface (Modbus RTU protocol) for integration into centralized lab management systems. When paired with third-party data acquisition software compliant with FDA 21 CFR Part 11, they enable electronic record generation with audit trails, user access controls, and timestamped event logging — essential for GMP-regulated environments. All temperature profiles, runtime logs, and alarm histories can be exported in CSV format for traceability and statistical process analysis (SPC). Firmware updates are performed via USB port using manufacturer-provided configuration utilities, ensuring version control and regulatory alignment.

Applications

  • Drying of moisture-sensitive reagents and hygroscopic compounds prior to gravimetric analysis (e.g., ASTM D2240, ISO 17190).
  • Baking of coated substrates and thin-film samples in materials science R&D.
  • Pre-conditioning of filter media, membranes, and chromatography columns.
  • Sterilization of glassware and stainless steel tools via dry-heat methods (160°C for 120 min per ISO 17665-1).
  • Melting point determination support through controlled wax and polymer melt stabilization.
  • Residual solvent removal from synthesized APIs under cGMP-compliant environmental monitoring.

FAQ

What is the difference between the DHG-9076A and DHG-9076Y models?
The DHG-9076Y variant includes an upgraded microcontroller with enhanced data logging capacity and extended timer functionality (up to 9999 minutes with repeat-cycle mode), whereas the DHG-9076A offers standard timing and basic data retention.
Does this oven support external calibration verification?
Yes — the unit features a dedicated PT100 sensor port for connection to external calibrated reference thermometers, enabling periodic accuracy verification per ISO/IEC 17025 Clause 6.5.2.
Can the oven be qualified for GMP use?
It supports IQ/OQ execution with documented protocols; however, final PQ must be performed in situ using user-defined acceptance criteria aligned with process requirements and regulatory expectations.
Is the stainless steel chamber electropolished?
No — the interior uses brushed-finish SUS304 stainless steel, suitable for routine cleaning and compatible with common laboratory disinfectants (e.g., 70% ethanol, diluted sodium hypochlorite).
What maintenance is required for long-term reliability?
Biannual inspection of blower motor bearings, gasket integrity, and heater element continuity is recommended; filter cleaning (if equipped) every 3 months prevents airflow restriction and thermal drift.