Empowering Scientific Discovery

NFN3000 Digital Creammeter Reading Station (German-Made)

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Origin Germany
Manufacturer Type Authorized Distributor
Origin Category Imported
Model NFN3000
Pricing Available Upon Request

Overview

The NFN3000 Digital Creammeter Reading Station is a precision-engineered optical support platform designed specifically for standardized, repeatable interpretation of centrifugal cream separation results in dairy quality control laboratories. It operates on the principle of vertical alignment and calibrated magnification to eliminate parallax error and operator-induced variability during reading of standardized Gerber or Babcock cream tubes. Unlike handheld visual estimation—which introduces angular deviation, inconsistent lighting conditions, and subjective meniscus interpretation—the NFN3000 provides a fixed-axis viewing geometry with integrated backlighting and scale registration, ensuring traceable, GLP-compliant measurement of fat column height in accordance with ISO 1735:2022 (Milk and milk products — Determination of fat content — Gerber method) and IDF Standard 14C:2018. The device does not perform analysis itself but serves as a metrologically validated interface between the centrifuged tube and the human observer, fulfilling a critical role in method validation and inter-laboratory reproducibility.

Key Features

  • Fixed vertical optical axis with 12° inclined viewing angle optimized for Gerber tube meniscus alignment per ISO 1735 requirements
  • Integrated LED backlight system with adjustable intensity (10–100% stepless control) to enhance contrast of fat layer boundaries under varying ambient light conditions
  • Calibrated vernier scale overlay (0.1 mm resolution) mounted on a rigid aluminum alloy chassis with anti-vibration base plate
  • Dual-position tube holder accommodating both 10 mL Gerber-type and 18 mL Babcock-type glass tubes without tooling change
  • Non-contact, non-destructive operation—no mechanical pressure applied to fragile glass tubes during reading
  • Compliance-ready documentation package including factory calibration certificate (traceable to PTB, Braunschweig) and user verification protocol

Sample Compatibility & Compliance

The NFN3000 supports all standard dairy fat determination tubes conforming to ISO 1735, AOAC Official Method 920.116, and USP . It is compatible with borosilicate glass tubes (e.g., Schott Duran®-grade) used in Gerber, Babcock, and Mojonnier procedures. No sample preparation or reagent addition is required—the instrument interfaces exclusively with the final centrifuged tube post-analysis. Its design aligns with Good Laboratory Practice (GLP) requirements for documented, observer-independent measurement steps and supports audit readiness for ISO/IEC 17025-accredited laboratories. While not an analytical instrument per se, its use is explicitly referenced in Annex A of ISO 1735 as a recommended means of minimizing reading uncertainty in routine dairy fat testing.

Software & Data Management

The NFN3000 is a standalone optical aid and does not incorporate embedded firmware, connectivity, or digital data output. This intentional design ensures operational reliability, eliminates cybersecurity concerns, and avoids software validation burdens under FDA 21 CFR Part 11 or EU Annex 11. All readings are manually recorded by the analyst into laboratory notebooks or LIMS-compatible spreadsheets. Optional companion documentation templates—including digital PDF checklists for daily verification, calibration log sheets, and uncertainty budget worksheets—are available from the authorized distributor to support compliance with ISO/IEC 17025 Clause 7.7 (Ensuring validity of results) and internal QA protocols.

Applications

  • Routine fat quantification in raw milk, pasteurized milk, cream, and whey at dairy processing plants and regulatory testing labs
  • Method validation and operator training for ISO 1735-compliant fat analysis workflows
  • Inter-laboratory comparison studies requiring minimized observer bias across multiple analysts
  • Reference laboratory support for proficiency testing schemes administered by ILAC-MRA signatories
  • Quality assurance audits where documented reading consistency is mandated by GMP or HACCP plans

FAQ

Does the NFN3000 measure fat content directly?

No—it provides a standardized optical platform for accurate visual reading of fat column height in centrifuged Gerber/Babcock tubes; final fat percentage calculation follows established gravimetric or volumetric conversion formulas.
Is calibration required before each use?

A daily verification using the included reference gauge block is recommended; full recalibration by an accredited metrology lab is advised every 12 months or after physical impact.
Can it be used with plastic disposable tubes?

No—only certified borosilicate glass tubes meeting ISO 1735 dimensional tolerances are supported due to refractive index consistency and thermal stability requirements.
What documentation accompanies the unit?

Factory calibration certificate (PTB-traceable), CE Declaration of Conformity, ISO 1735 application note, and GLP implementation guide.
Is technical support available in English-speaking regions?

Yes—authorized distributors provide remote troubleshooting, verification protocol assistance, and on-site training upon request.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0