Yoyi DHG-9030A Forced-Air Constant-Temperature Drying Oven
| Brand | Yoyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DHG-9030A |
| Instrument Type | General-Purpose Drying Oven |
| Temperature Range | RT+10°C to 250°C |
| Temperature Uniformity | ±2.5% (at 100°C) |
| Temperature Fluctuation | ±1.0°C |
| Temperature Resolution | 0.1°C |
| External Dimensions | 625 × 540 × 500 mm |
| Internal Chamber Dimensions | 340 × 330 × 320 mm |
| Internal Chamber Material | Mirror-Finish Stainless Steel |
| Heating Method | Electric Resistance Heating |
| Power Input | 850 W |
| Rated Voltage/Frequency | AC 220 V / 50 Hz |
| Net Volume | 30 L |
| Standard Shelving | 2 Adjustable Stainless Steel Trays |
| Timer Range | 1–9999 min |
| Operating Ambient Temperature | +5°C to +40°C |
| Humidity Limit | ≤80% RH (non-condensing) |
| Compliance | GB/T 30435–2013 |
Overview
The Yoyi DHG-9030A is a precision-engineered forced-air constant-temperature drying oven designed for routine and research-grade thermal processing in laboratory and quality control environments. Utilizing convection-based heat transfer via an integrated axial fan and optimized air duct architecture, the unit ensures rapid thermal equilibration and high spatial temperature uniformity across its 30 L stainless-steel chamber. Its operational range spans from ambient +10°C to 250°C—covering standard drying, baking, sterilization, moisture loss determination, polymer conditioning, and pre-heat protocols required in pharmaceutical stability testing, materials science, food analysis, and electronics component validation. The oven complies fully with GB/T 30435–2013, the Chinese national standard governing performance verification, safety requirements, and metrological traceability of electric heating ovens. All critical thermal parameters—including setpoint, real-time chamber temperature, elapsed time, and remaining hold duration—are displayed simultaneously on a backlit LCD interface, supporting intuitive operation without external instrumentation.
Key Features
- Microprocessor-controlled PID temperature regulation with 0.1°C resolution and ±1.0°C fluctuation tolerance under no-load conditions
- Dual-layer tempered glass observation window with silicone-sealed frame for continuous visual monitoring without thermal disruption
- High-efficiency rear-mounted centrifugal blower with directional air ducts enabling uniform airflow distribution and ±2.5% temperature uniformity at 100°C
- Mirror-finish 304 stainless-steel interior chamber resistant to corrosion, oxidation, and organic residue buildup; compatible with repeated cleaning using ethanol, isopropanol, or mild alkaline solutions
- Electrostatically coated cold-rolled steel exterior housing providing mechanical durability and chemical resistance in shared lab environments
- Intelligent power-loss recovery function retaining user-defined parameters (set temperature, timer, alarm thresholds) during unexpected outages
- Independent over-temperature cut-off circuit (optional) meeting IEC 61000-4-5 surge immunity and EN 60519-2 safety criteria for industrial heating equipment
- Standard 25 mm diameter test port (optional 50 mm) for integration with external sensors, data loggers, or inert gas supply lines
Sample Compatibility & Compliance
The DHG-9030A accommodates a broad spectrum of sample formats including Petri dishes, weighing boats, glass vials, aluminum pans, ceramic crucibles, and polymer film substrates—provided dimensional constraints (max. 330 mm depth × 320 mm height) are observed. Its chamber geometry supports ISO/IEC 17025-compliant validation protocols for temperature mapping (per ASTM E2251 and EU GMP Annex 15), and it is routinely deployed in laboratories adhering to USP , FDA 21 CFR Part 11 (when paired with optional RS485 data logging), and GLP audit frameworks. The stainless-steel construction meets FDA-recommended material compatibility guidelines for non-sterile pharmaceutical manufacturing support functions. For applications requiring inert atmospheres—such as oxygen-sensitive catalyst drying or low-oxygen thermal aging—the optional nitrogen purge kit (including calibrated rotameter and quick-connect fittings) enables precise flow control between 0.5–5 L/min.
Software & Data Management
While the base configuration operates via embedded firmware only, the optional RS485 serial interface (Modbus RTU protocol) permits bidirectional communication with third-party SCADA systems, LIMS platforms, or custom Python/MATLAB scripts for automated temperature profiling and long-term trend analysis. When equipped with the embedded thermal printer option, the oven generates timestamped hardcopy records of temperature history, start/stop events, and alarm triggers—supporting 21 CFR Part 11 compliance when used with appropriate electronic signature workflows. All parameter changes—including setpoint adjustments, timer resets, and alarm threshold modifications—are logged internally with date/time stamps and retained for ≥30 days, satisfying internal audit requirements for instrument usage traceability.
Applications
- Moisture content determination per AOAC 950.46 and ISO 5530–1 in food, feed, and agricultural commodities
- Pre-drying of filter papers, pipette tips, and glassware prior to gravimetric analysis
- Thermal conditioning of epoxy resins, thermoplastics, and composite laminates prior to mechanical testing
- Baking of printed circuit board (PCB) assemblies to remove residual solvents before conformal coating
- Accelerated aging studies of packaging materials under controlled thermal stress (ASTM F1980)
- Dehydration of biological specimens for histological embedding or SEM sample preparation
- Stabilization of reference standards and calibration weights in metrology labs
FAQ
What is the maximum safe operating temperature for continuous use?
The DHG-9030A is rated for continuous operation up to 250°C. Prolonged exposure above this limit may compromise gasket integrity and sensor accuracy.
Can the oven be validated for ISO/IEC 17025 accreditation?
Yes—its design supports full IQ/OQ/PQ execution per ISO/IEC 17025:2017 Annex A.3, including mapping with ≥9 thermocouples, stability assessment over 3 hours, and uniformity verification at three load conditions.
Is the stainless-steel chamber electropolished?
No—the interior features mechanically polished 304 stainless steel (Ra ≤ 0.8 µm), sufficient for routine cleaning and compliant with pharmaceutical equipment surface finish standards.
Does the unit include a built-in calibration certificate?
Factory calibration is performed using NIST-traceable reference thermometers; a Certificate of Conformance is supplied. Optional UKAS-accredited calibration (with uncertainty budget) is available upon request.
What maintenance intervals are recommended?
Fan lubrication and door seal inspection every 6 months; annual verification of temperature sensor drift against a calibrated reference probe per ISO 17025 Clause 6.5.2.