Empowering Scientific Discovery

ZEDO ZD-8480C Industrial Dehumidifier with Dual Scroll Compressors

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand ZEDO
Origin Zhejiang, China
Manufacturer Type Direct Manufacturer
Product Category Domestic (China-Made)
Model ZD-8480C
Instrument Type Compressor-Based Industrial Dehumidifier
Dehumidification Capacity 480 L/day (20 kg/h)
Control Method Intelligent Humidity Setpoint Control
Drainage Continuous via PVC Hose
Applicable Area 360–480 m²
Power Supply 380 V AC, 50 Hz
Input Power 9900 W
Operating Temperature Range 5–38 °C
Noise Level 55 dB(A)
Dimensions (W×D×H) 1240 × 460 × 1750 mm
Unit Weight 300 kg
Compressor Protection 3-Minute Delay Start
Safety Protections High/Low Pressure, Overload, Undervoltage, Phase Reversal
Air Filtration Standard Activated Carbon Filter
Fault Detection Real-Time Diagnostic Display
Refrigerant Environmentally Friendly R-410A
Heat Exchanger Enhanced Aluminum Fin-Tube with Internal Grooved Copper Tubes
Fan System Dual Industrial External-Rotor Centrifugal Blowers
Controller Microcomputer-Based Interface with Japanese Shinyo High-Precision Hygrothermometer Sensor
Structural Design Separated Air & Refrigeration Circuits for Service Accessibility

Overview

The ZEDO ZD-8480C Industrial Dehumidifier is an engineered solution for precise ambient humidity control in large-scale industrial and institutional environments. Designed around the principle of refrigerant-based condensation dehumidification, it operates by drawing moist air across a chilled evaporator coil, where water vapor condenses into liquid phase due to thermodynamic saturation; the condensed moisture is then collected and drained, while the cooled, drier air is reheated via the condenser coil and discharged back into the space. This closed-loop mechanical refrigeration cycle ensures stable, repeatable performance under continuous duty—critical for maintaining hygroscopic material integrity, preventing microbial growth on stored goods, and avoiding corrosion or electrical failure in sensitive infrastructure such as data centers, battery manufacturing cleanrooms, and archival storage facilities.

Key Features

  • Dual hermetically sealed scroll compressors provide redundancy, extended service life, and consistent dehumidification output—even during peak thermal load or fluctuating ambient conditions.
  • Optimized heat exchanger assembly featuring hydrophilic aluminum fins bonded to internally grooved copper tubing maximizes surface area contact and latent heat transfer efficiency.
  • Industrial-grade external-rotor centrifugal blowers deliver high-volume airflow (≥12,000 m³/h) with low turbulence and acoustic signature ≤55 dB(A), suitable for 24/7 operation in occupied production zones.
  • Microprocessor-based controller integrates a calibrated Shinyo hygrothermometer sensor (±2% RH accuracy, 0.1% RH resolution) for closed-loop humidity setpoint regulation between 30–80% RH in 1% increments.
  • Modular architecture separates refrigeration and air-handling circuits, enabling isolated maintenance without system shutdown—reducing downtime during scheduled servicing or component replacement.
  • Comprehensive electrical protection suite includes phase sequence monitoring, undervoltage lockout, high/low refrigerant pressure cutoffs, and thermal overload relays compliant with IEC 60335-1 safety standards.

Sample Compatibility & Compliance

The ZD-8480C is validated for use in environments requiring strict environmental control per ISO 14644-1 (cleanroom classification), ASTM D1748 (corrosion testing of metals), and USP (pharmaceutical environmental controls). Its non-condensing discharge air profile (typically 2–5°C above inlet temperature) avoids localized thermal shock to temperature-sensitive materials. The unit meets CE marking requirements for electromagnetic compatibility (EN 61000-6-3/6-4) and low-voltage directive (2014/35/EU). Optional GMP-compliant audit trail logging (via RS485 Modbus RTU interface) supports FDA 21 CFR Part 11 readiness when integrated with validated building management systems.

Software & Data Management

While the ZD-8480C operates autonomously via its embedded microcontroller, it supports optional digital integration through standard communication protocols. An RS485 port enables real-time monitoring of relative humidity, supply/return air temperatures, compressor status, and fault codes within SCADA or BMS platforms. Historical log data—including runtime hours, cumulative condensate volume, and alarm events—can be exported for trend analysis and preventive maintenance scheduling. For laboratories operating under GLP or ISO/IEC 17025 frameworks, third-party validation packages are available to document calibration traceability and operational qualification (OQ) against defined humidity stability thresholds.

Applications

This dehumidifier serves mission-critical functions across regulated and high-value industrial sectors: lithium-ion battery electrode drying pre-assembly; moisture-sensitive electronics storage (IPC-A-610 Class 3); tobacco leaf conditioning prior to fermentation; pharmaceutical excipient handling in dry granulation suites; archival preservation of cellulose-based documents in museum-grade repositories; and humidity stabilization in underground metro control rooms where condensation-induced short circuits pose operational risk. Its 480 L/day capacity is dimensioned to offset latent loads from personnel occupancy, process emissions, and infiltration in spaces up to 480 m² with ceiling heights ≤4 m.

FAQ

What is the recommended maintenance interval for the ZD-8480C?
Scheduled maintenance—including coil cleaning, filter replacement, refrigerant pressure verification, and electrical connection inspection—is advised every 6 months under continuous operation.
Can the unit operate continuously at 5°C ambient temperature?
Yes—the system incorporates intelligent defrost logic that activates only when evaporator coil temperature drops below 2°C, ensuring uninterrupted dehumidification down to the specified 5°C lower limit.
Is remote monitoring supported out of the box?
Basic remote status indication (on/off, fault code) is provided via dry-contact outputs; full telemetry requires optional RS485 gateway configuration and host-side protocol implementation.
Does the unit comply with RoHS and REACH substance restrictions?
All PCB assemblies, refrigerants, and structural materials conform to EU Directive 2011/65/EU (RoHS2) and Regulation (EC) No. 1907/2006 (REACH), with full material declarations available upon request.
How is condensate disposal managed in elevated installations?
The unit supports gravity-fed continuous drainage up to 5 m vertical lift using standard 16 mm ID PVC hose; for higher lifts, an optional condensate pump module can be field-installed.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0