Accelerated Solvent Extractor
Filter
Showing 1–30 of 33 results
| Brand | Accroma |
|---|---|
| Origin | Switzerland |
| Model | Accroma |
| Extraction Type | Liquid-Liquid Extraction |
| Temperature Range | −20 °C to 40 °C |
| Dimensions | 144 × 113 × 200 cm |
| Sample Capacity | 124 positions |
| Compliance | Designed for GLP/GMP-aligned workflows, supports 21 CFR Part 11–compliant audit trails |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | APL-ASE200 |
| Instrument Type | Solid-Liquid Extraction |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | 0–20 MPa |
| Extraction Cell Volume | 40 mL (standard) |
| optional volumes | 1, 5, 10, 22, 66, and 100 mL |
| Typical Extraction Time | 8–20 min per sample |
| Dimensions | 600 × 600 × 700 mm |
| Compliance | HJ 782–2016, HJ 783–2016, GB/T 23200.9–2016, ASTM D7567–2009 |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Aseeker-600 |
| Instrument Category | Solid-Liquid Extraction |
| Temperature Range | Ambient to 200 °C (±0.5 °C) |
| Pressure Range | 0–20 MPa (±0.3 MPa) |
| Extraction Cell Volumes | 10 mL / 20 mL / 40 mL |
| Throughput | 6 samples in 20 min |
| Dimensions (W×D×H) | 770 mm × 608 mm × 755 mm |
| Weight | 95 kg |
| Solvent Consumption per Sample | 5–200 mL |
| Pump Flow Rate | 0.1–50 mL/min |
| Power Requirement | 100–240 VAC ±10 %, 50–60 Hz |
| Max Power Consumption | 1.7 kW |
| Gas Supply | Lab-grade nitrogen, 0.4–1 MPa |
| Solvent Mixing Capability | Up to 4 solvents |
| Collection Vial Capacity | 250 mL |
| Cleaning Stations | 6 |
| Sample Contact Materials | PEEK, PTFE, 316L stainless steel, ceramic |
| Brand | b.safe |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | b.safe HPLC Solvent Delivery Kit |
| Pricing | Upon Request |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Instrument Type | Solid-Liquid Extraction System |
| Model | E-914 |
| Temperature Range | 50–200 °C |
| Pressure Range | 50–150 bar |
| Extraction Cell Volumes | 40, 60, 80, 120 mL |
| Extraction Time per Batch | 20–40 min |
| Sample Capacity | 4 positions |
| Dimensions (W × D × H) | 670 × 725 × 500 mm |
| Nitrogen Supply | 5–10 bar |
| Solvent Mixer | 4-port |
| Pump Flow Rate | 50 mL/min |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EDGE |
| Instrument Type | Liquid–Solid Extraction |
| Temperature Range | 100–200 °C |
| Pressure Range | 13.8 MPa |
| Extraction Cell Volumes | 11 / 22 / 34 / 66 mL |
| Extraction Time | 5 min per sample |
| Instrument Dimensions | 360 mm (W) |
| Sample Capacity | 24 positions (dual rack, 12 per run) |
| Brand | Euro Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ET3200B |
| Price Range | USD 1,400–7,000 |
| Instrument Type | Liquid-Liquid Extraction |
| Extraction Vessel Volume | 500 mL × 3 |
| Extraction Cycle Time | 1–5 min per station |
| Dimensions (W×D×H) | 460 × 250 × 650 mm |
| Sample Positions | 3 |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 30 W |
| Net Weight | 15.7 kg |
| Operating Principle | Mechanical Stirring-Assisted Phase Separation |
| Brand | Euro Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ET3200C |
| Instrument Type | Liquid-Liquid Extraction |
| Extraction Vessel Volume | 1000 mL × 3 |
| Extraction Time Range | 1–5 min per station |
| Dimensions (W×D×H) | 460 × 250 × 650 mm |
| Sample Throughput | 3 independent stations |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 20 W |
| Net Weight | 15.7 kg |
| Brand | Haiguang Instruments |
|---|---|
| Origin | Beijing, China |
| Model | HGE-300 |
| Extraction Type | Solid-Liquid Extraction |
| Sample Capacity | Up to 24 Positions |
| Solvent Handling | Automated Switching, Blending, and Proportional Mixing of Up to 4 Solvents |
| Sealing Material | TFM (Perfluoroalkoxy) Gaskets |
| Safety Features | Integrated Pneumatic Circuit Protection Against Solvent Corrosion and Backflow |
| Compliance Context | Designed for GLP-compliant laboratories |
| Brand | Hookoins |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 210 °C |
| Pressure Range | 0–20 MPa |
| Extraction Cell Volume | 5–120 mL |
| Extraction Time per Cycle | ≤30 min |
| Dimensions (W×D×H) | 690 × 535–715 mm |
| Sample Throughput | 6 parallel positions |
| Heating Uniformity | Full-wrap 6-channel furnace |
| Control Interface | High-resolution color touchscreen with graphical workflow display |
| Solvent Delivery | Quaternary solvent blending system (4 independent solvent lines) |
| Pump Specifications | 0–100 mL/min, max. 260 bar |
| Integrated Safety | Real-time pressure/temperature monitoring per channel, seal-cycle counter, solvent-level alarm, automatic pressure relief, N₂ purge and solvent flush |
| Online Conditioning | In-line water removal and matrix cleanup modules |
| Collection Vessel Compatibility | 60–250 mL bottles (customizable) |
| Power Requirement | 220 V AC, 50/60 Hz, 1800 W max |
| Operating Environment | 0–35 °C, ≤80% RH |
| N₂ Supply | 6–10 bar inlet pressure |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Aseeker-100 |
| Instrument Category | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C (±1 °C) |
| Pressure Range | 0–20 MPa (±0.3 MPa) |
| Extraction Cell Volumes | 11 mL / 22 mL / 33 mL |
| Collection Vial Capacities | 40 mL / 60 mL |
| Solvent Flow Rate | 0.1–50 mL/min |
| Extraction Time | 20–30 min |
| Solvent Consumption | 10 mL per 10 g sample |
| Gas Supply Requirement | Nitrogen, 0.4–1 MPa |
| Power Input | 100–240 VAC ±10 %, 50–60 Hz |
| Max. Power Consumption | 600 W |
| Dimensions (W×D×H) | 450 mm × 500 mm × 530 mm |
| Weight | 30 kg |
| Sample Contact Materials | PEEK, PTFE, 316L stainless steel, ceramic |
| Safety Features | Mechanical overpressure protection, electronic overtemperature cutoff, leak detection with automatic shutdown, liquid-level sensing with overflow prevention, integrated post-extraction filtration |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Aseeker-200 |
| Instrument Category | Solid-Liquid Extraction |
| Temperature Range | Ambient to 200 °C (±1 °C) |
| Pressure Range | 0–20 MPa (±0.3 MPa) |
| Extraction Cell Volumes | 10 mL / 34 mL / 66 mL / 100 mL |
| Extraction Time | 20–30 min |
| Solvent Consumption | 10 mL per 10 g sample |
| Pump Flow Rate | 0.1–50 mL/min |
| Collection Vial Capacities | 60 mL / 250 mL |
| Gas Supply Requirement | Nitrogen at 0.9–1.2 MPa |
| Power Input | 100–240 VAC ±10 %, 50–60 Hz |
| Max Power Consumption | 1.2 kW |
| Dimensions (W×D×H) | 508 mm × 485 mm × 745 mm |
| Weight | 40 kg |
| Wetted Materials | PEEK, PTFE, 316L stainless steel, ceramic |
| Safety Features | Mechanical overpressure protection, electronic overtemperature cutoff, leak detection, liquid-level sensing, pressure-deficiency alarm, automatic filtration post-extraction, dual-needle purge system to prevent splashing |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | Aseeker-500 |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C (±0.5 °C) |
| Pressure Range | 10 MPa (±0.5 MPa) |
| Extraction Cell Volume | Standard 34 mL (optional: 1, 5, 10, 22, 66, 100 mL) |
| Extraction Time per Sample | 20 min |
| Instrument Dimensions | 800 mm × 738 mm × 685 mm |
| Sample Capacity | 24 extraction cells |
| Collection Vials | Standard 19 × 250 mL or up to 28 × 60 mL + 5 × 250 mL with adapter |
| Pump Flow Rate | 0.1–50 mL/min |
| Power Consumption | ≤1.2 kW |
| Input Voltage | 100–240 VAC ±10 %, 50–60 Hz |
| Solvent Mixing Capability | Up to 4 solvents |
| Cleaning Stations | 2 |
| Weight | 70 kg |
| Contact Materials | PEEK, PTFE, 316L stainless steel, ceramic |
| Safety Features | Electronic over-pressure/over-temperature protection, leak detection with automatic shutdown and sequence bypass, external air supply pressure monitoring, infrared liquid-level sensing at collection vials |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Flex-HPSE 1H |
| Pricing | Available upon Request |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Flex-HPSE |
| Instrument Type | Solid-Liquid Extraction |
| Temperature Range | 50–200 °C |
| Pressure Range | 10.3–20.6 MPa |
| Extraction Cell Volume | 15–45 mL |
| Extraction Time per Cycle | 12–18 min |
| Dimensions (W×D×H) | 1112 × 939 × 672 mm |
| Throughput | Dual-channel, 30-position automated sequential processing |
| Compliance | Designed for ISO 13877, EPA Method 3545A, ASTM D7699, and USP <467> applications |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HPSE Series |
| Instrument Type | Solid-Phase Extraction (SPE) / Pressurized Liquid Extraction (PLE) |
| Temperature Range | 0–50 °C |
| Pressure Range | Up to 10 MPa |
| Extraction Cell Volume | 10–100 mL (standard configuration supports 100 mL cells) |
| Flow Rate | Up to 100 mL/min |
| Dimensions (W × D × H) | 500 × 600 × 650 mm |
| Sample Capacity | 6 positions (modular |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HPSE |
| Instrument Type | Solid-Liquid Extraction System |
| Sample Throughput | Up to 6 parallel extraction cells |
| Extraction Vessel Capacity | Compatible with 1–100 mL vessels |
| Temperature Range | Programmable, typically 50–200 °C (application-dependent) |
| Pressure Range | Up to 20 MPa (3,000 psi), dynamically regulated |
| Pump Flow Rate | 100 mL/min |
| Sealing Mechanism | Auto-actuated force-assisted sealing |
| Enclosure | Fully sealed, ventilation-integrated chassis |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Polytech |
|---|---|
| Model | HPSE-06 |
| Extraction Channels | 6 parallel |
| Temperature Range | Ambient to 210 °C (±1 °C control accuracy) |
| Pressure Range | 0–20 MPa |
| Pump Flow Rate | 0–100 mL/min |
| Maximum Pump Output Pressure | 26 MPa |
| Solvent Selection | Quaternary solvent system with programmable mixing ratios |
| Extraction Cell Volumes | 5, 10, 34, 40, 66, 80, 100, 120 mL (customizable) |
| Cell Material | Electropolished stainless steel or specialty alloy with PTFE seals |
| Collection Vial Capacity | 60–250 mL |
| Safety Systems | Integrated pressure regulation, overpressure cutoff, gas–liquid isolation protection |
| Interface | Bilingual (Chinese/English) graphical LCD with real-time extraction profile visualization, self-diagnostic capability, and automated nitrogen/solvent purge cycles |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | QSE-100 |
| Instrument Type | Solid-Liquid Extraction System |
| Sample Throughput | Up to 12 positions (standard configuration) |
| Operating Temperature Range | Ambient to 200 °C |
| Maximum System Pressure | 200 bar |
| Extraction Cell Volume Options | 1 mL, 5 mL, 10 mL, 22 mL, 34 mL, 66 mL, 100 mL |
| Typical Extraction Time per Sample | 12–25 min (including heat-up, static extraction, flush, and purge cycles) |
| Solvent Compatibility | Polar and non-polar organic solvents (e.g., hexane, acetone, methanol, dichloromethane), water, and solvent mixtures |
| Dimensions (W×D×H) | 580 mm × 620 mm × 650 mm |
| Net Weight | ~75 kg |
| Safety Compliance | CE-marked |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-200QSE |
| Extraction Type | Solid-Liquid Extraction |
| Automation Level | Fully Automated |
| Compliance Context | Designed for GLP-compliant laboratories |
| Software Interface | Touchscreen GUI with method storage and audit trail capability |
| Safety Features | Pressure-relief valves, temperature/pressure real-time monitoring, leak detection |
| Sample Throughput | Batch processing with programmable sequence execution |
| Solvent Compatibility | Compatible with common organic solvents (e.g., hexane, acetone, dichloromethane, methanol, ethyl acetate) |
| System Architecture | Modular solvent delivery, heated extraction cell, cooled collection module |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-600QSE |
| Extraction Type | Solid-Liquid Extraction |
| Compliance | EPA Method 3545A |
| Channel Configuration | 6 Parallel Independent Channels |
| Extraction Cell Volumes | 11 mL, 22 mL, 34 mL |
| Max Cell Temperature | 200 °C |
| Safety Feature | Over-Temperature Cut-Off |
| Collection Vial Options | 40 mL / 50 mL / 60 mL |
| Flow Direction | Top-to-Bottom Vertical Elution |
| Cell Positioning | Fixed Vertical Alignment |
| Solvent Pressure Monitoring | Real-Time Alarm Function |
| System Architecture | Fully Automated, Channel-Isolated Fluidics |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | LEXT |
| Instrument Type | Liquid-Liquid Extraction System |
| Temperature Range | 0–130 °C |
| Pressure Condition | Ambient (Atmospheric) |
| Extraction Cell Volume | 15 mL |
| Typical Extraction Cycle Time | 10 min |
| Dimensions (W×D×H) | 600 mm × 585 mm × 570 mm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ASE 150 |
| Instrument Type | Solid-Phase Extraction System (ASE) |
| Operating Temperature Range | Up to 200 °C |
| Maximum Pressure | 1500 psi |
| Pump Flow Rate | 70 mL/min |
| Sample Capacity | 1–100 g |
| Extraction Cell Volumes | 1, 5, 10, 22, 34, 66, and 100 mL |
| Solvent Consumption Reduction | 50–90% vs. Soxhlet or Ultrasonic Extraction |
| Fluid Path Material | Dionium™ (chemically inert, acid- and base-resistant) |
| Integrated Filtration | On-line filtration and in-cell cleaning capability |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ASE 350 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | ASE+Rocket |
| Instrument Type | Accelerated Solvent Extractor (ASE) with Integrated Rotary Evaporation |
| Price Range | USD 42,000 – 70,000 (FOB US Port) |
| Extraction Principle | High-Temperature/High-Pressure Static-Dynamic Solvent Extraction |
| Brand | Thermo Fisher |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | EXTREVA™ ASE™ Accelerated Solvent Extractor |
| Instrument Type | Solid-Liquid Extraction (not Liquid-Liquid) |
| Temperature Range | 40–200 °C |
| Pressure Range | 200 bar (corrected from erroneous "200 Pa") |
| Extraction Cell Volumes | 1, 5, 10, 22, 34, 66, and 100 mL |
| Extraction Time | 2–300 min |
| Dimensions (W×D×H) | 100 × 65.2 × 86.6 cm |
| Sample Capacity | Dual trays, 16 positions total |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | ASE350 |
| Extraction Type | Solid-phase accelerated solvent extraction (ASE) |
| Pressure Range | 1500 psi |
| Temperature Range | Up to 200 °C |
| Flow Rate | 70 mL/min |
| Extraction Cell Volumes | 1, 5, 10, 22, 34, 66, and 100 mL |
| Solvent Options | Up to 3 solvents programmable per method |
| Solvent Consumption | <50 mL per 20 g sample (typical) |
| Automation Capacity | Up to 24 samples unattended |
| Compliance | Designed for GLP/GMP environments |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | APLE-1000 |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | Atmospheric to 18 MPa (2700 psi) |
| Extraction Cell Volumes | 1 mL, 5 mL, 10 mL, 22 mL, 34 mL, 66 mL, 100 mL, 150 mL |
| Extraction Cycle Time | 8–20 min per sample |
| Dimensions (W×D×H) | 86 × 76 × 73 cm |
| Sample Capacity | 26 positions (24 sample + 2 cleaning) |
| Heating System | Single-zone furnace with ±1 °C temperature control |
| Pressure Control | Balanced pressure regulation, active control initiated at ±0.3 MPa deviation |
| Filtration & Cleanup | Integrated inline filtration and post-extraction cleanup module |
| Safety Features | Real-time temperature/pressure monitoring with audible/visual alarm |
| Compliance | Designed in accordance with GB/T 19649–2006 for pesticide residue analysis in agricultural products |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | Atmospheric to 20 MPa |
| Extraction Cell Volumes | 1 mL, 5 mL, 10 mL, 22 mL, 34 mL, 66 mL, 100 mL |
| Cycle Time per Sample | 8–20 min |
| Dimensions | 78.3 × 67.5 × 77.3 cm |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | APLE-3500 |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | Atmospheric to 20 MPa |
| Extraction Cell Volumes | 1 mL, 5 mL, 11 mL, 22 mL, 34 mL, 66 mL, 100 mL |
| Extraction Cycle Time | 15–20 min per sample |
| Dimensions (W×D×H) | 86 cm × 76 cm × 73 cm |
| Sample Capacity | 26 positions (24 sample + 2 rinse positions) |