Accelerated Solvent Extractor
Filter
Showing 31–53 of 53 results
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | HPFE 06 |
| Instrument Type | Solid-Liquid Extraction |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | Atmospheric to 20 MPa |
| Extraction Cell Volumes | 11, 22, 33, 66, 80, 120 mL |
| Extraction Time | ≤15 min per cycle |
| Dimensions (L×W×H) | 720 × 560 × 790 mm |
| Sample Capacity | 96 positions |
| Solvent Options | 4 independent solvent channels with programmable mixing ratios |
| Collection Vial Compatibility | 60–240 mL |
| Safety Features | Over-pressure, over-temperature, and leak detection with active ventilation and sealed chamber architecture |
| Software Interface | Built-in 10-inch fixed industrial touchscreen with method editor and audit trail logging |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | QSE-100 |
| Instrument Type | Solid-Liquid Extraction System |
| Sample Throughput | Up to 12 positions (standard configuration) |
| Operating Temperature Range | Ambient to 200 °C |
| Maximum System Pressure | 200 bar |
| Extraction Cell Volume Options | 1 mL, 5 mL, 10 mL, 22 mL, 34 mL, 66 mL, 100 mL |
| Typical Extraction Time per Sample | 12–25 min (including heat-up, static extraction, flush, and purge cycles) |
| Solvent Compatibility | Polar and non-polar organic solvents (e.g., hexane, acetone, methanol, dichloromethane), water, and solvent mixtures |
| Dimensions (W×D×H) | 580 mm × 620 mm × 650 mm |
| Net Weight | ~75 kg |
| Safety Compliance | CE-marked |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-200QSE |
| Extraction Type | Solid-Liquid Extraction |
| Automation Level | Fully Automated |
| Compliance Context | Designed for GLP-compliant laboratories |
| Software Interface | Touchscreen GUI with method storage and audit trail capability |
| Safety Features | Pressure-relief valves, temperature/pressure real-time monitoring, leak detection |
| Sample Throughput | Batch processing with programmable sequence execution |
| Solvent Compatibility | Compatible with common organic solvents (e.g., hexane, acetone, dichloromethane, methanol, ethyl acetate) |
| System Architecture | Modular solvent delivery, heated extraction cell, cooled collection module |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-600QSE |
| Extraction Type | Solid-Liquid Extraction |
| Compliance | EPA Method 3545A |
| Channel Configuration | 6 Parallel Independent Channels |
| Extraction Cell Volumes | 11 mL, 22 mL, 34 mL |
| Max Cell Temperature | 200 °C |
| Safety Feature | Over-Temperature Cut-Off |
| Collection Vial Options | 40 mL / 50 mL / 60 mL |
| Flow Direction | Top-to-Bottom Vertical Elution |
| Cell Positioning | Fixed Vertical Alignment |
| Solvent Pressure Monitoring | Real-Time Alarm Function |
| System Architecture | Fully Automated, Channel-Isolated Fluidics |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | LEXT |
| Instrument Type | Liquid-Liquid Extraction System |
| Temperature Range | 0–130 °C |
| Pressure Condition | Ambient (Atmospheric) |
| Extraction Cell Volume | 15 mL |
| Typical Extraction Cycle Time | 10 min |
| Dimensions (W×D×H) | 600 mm × 585 mm × 570 mm |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Operation Mode | Manual |
| Price | USD 4,200 (FOB) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ASE 150 |
| Instrument Type | Solid-Phase Extraction System (ASE) |
| Operating Temperature Range | Up to 200 °C |
| Maximum Pressure | 1500 psi |
| Pump Flow Rate | 70 mL/min |
| Sample Capacity | 1–100 g |
| Extraction Cell Volumes | 1, 5, 10, 22, 34, 66, and 100 mL |
| Solvent Consumption Reduction | 50–90% vs. Soxhlet or Ultrasonic Extraction |
| Fluid Path Material | Dionium™ (chemically inert, acid- and base-resistant) |
| Integrated Filtration | On-line filtration and in-cell cleaning capability |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ASE 350 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | ASE+Rocket |
| Instrument Type | Accelerated Solvent Extractor (ASE) with Integrated Rotary Evaporation |
| Price Range | USD 42,000 – 70,000 (FOB US Port) |
| Extraction Principle | High-Temperature/High-Pressure Static-Dynamic Solvent Extraction |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASE+Rocket |
| Quotation | Available Upon Request |
| Instrument Type | Accelerated Solvent Extraction (ASE) System with Integrated Evaporation |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestically Assembled |
| Model | ASE350 Accelerated Solvent Extractor (Domestically Assembled) |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | EXTREVA™ ASE™ Accelerated Solvent Extractor |
| Instrument Type | Solid-Liquid Extraction (not Liquid-Liquid) |
| Temperature Range | 40–200 °C |
| Pressure Range | 200 bar (corrected from erroneous "200 Pa") |
| Extraction Cell Volumes | 1, 5, 10, 22, 34, 66, and 100 mL |
| Extraction Time | 2–300 min |
| Dimensions (W×D×H) | 100 × 65.2 × 86.6 cm |
| Sample Capacity | Dual trays, 16 positions total |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | ASE350 |
| Extraction Type | Solid-phase accelerated solvent extraction (ASE) |
| Pressure Range | 1500 psi |
| Temperature Range | Up to 200 °C |
| Flow Rate | 70 mL/min |
| Extraction Cell Volumes | 1, 5, 10, 22, 34, 66, and 100 mL |
| Solvent Options | Up to 3 solvents programmable per method |
| Solvent Consumption | <50 mL per 20 g sample (typical) |
| Automation Capacity | Up to 24 samples unattended |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | EXTREVA ASE Accelerated Solvent Extractor and Concentrator |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | APLE-1000 |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | Atmospheric to 18 MPa (2700 psi) |
| Extraction Cell Volumes | 1 mL, 5 mL, 10 mL, 22 mL, 34 mL, 66 mL, 100 mL, 150 mL |
| Extraction Cycle Time | 8–20 min per sample |
| Dimensions (W×D×H) | 86 × 76 × 73 cm |
| Sample Capacity | 26 positions (24 sample + 2 cleaning) |
| Heating System | Single-zone furnace with ±1 °C temperature control |
| Pressure Control | Balanced pressure regulation, active control initiated at ±0.3 MPa deviation |
| Filtration & Cleanup | Integrated inline filtration and post-extraction cleanup module |
| Safety Features | Real-time temperature/pressure monitoring with audible/visual alarm |
| Compliance | Designed in accordance with GB/T 19649–2006 for pesticide residue analysis in agricultural products |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | Atmospheric to 20 MPa |
| Extraction Cell Volumes | 1 mL, 5 mL, 10 mL, 22 mL, 34 mL, 66 mL, 100 mL |
| Cycle Time per Sample | 8–20 min |
| Dimensions | 78.3 × 67.5 × 77.3 cm |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | APLE-3500 |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | Atmospheric to 20 MPa |
| Extraction Cell Volumes | 1 mL, 5 mL, 11 mL, 22 mL, 34 mL, 66 mL, 100 mL |
| Extraction Cycle Time | 15–20 min per sample |
| Dimensions (W×D×H) | 86 cm × 76 cm × 73 cm |
| Sample Capacity | 26 positions (24 sample + 2 rinse positions) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Solid-Liquid Extraction |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | Atmospheric to 20 MPa |
| Extract Cell Volumes | 1, 5, 11, 22, 34, 46, 66, and 100 mL (8 options) |
| Extraction Cycle Time | 10–20 min per 2 samples |
| Dimensions | 655 × 720 × 725 mm (W × D × H) |
| Sample Capacity | 26 positions (24 sample + 2 rinse) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | APLE-5000 |
| Extraction Type | Solid-Liquid Extraction |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | Atmospheric to 20 MPa |
| Extraction Cell Volumes | 1 mL, 5 mL, 11 mL, 22 mL, 34 mL, 46 mL |
| Extraction Time | 10–20 min per 2 samples |
| Dimensions (W×D×H) | 655 × 720 × 725 mm |
| Sample Capacity | 26 positions (24 sample + 2 cleaning) |
| Brand | Tongtai Union (TTL) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TTL-868 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 50 °C (±0.5 °C accuracy at 30 rpm) |
| Pressure Range | 0–5 MPa |
| Extraction Cell Volume | 2000 mL |
| Extraction Duration | 0–300 h |
| Dimensions (W×D×H) | 980 × 500 × 500 mm |
| Sample Capacity | 8 positions |
| Tilt Angle | 30° |
| Rotation Speed | 0–100 ±0.2 rpm (infinitely variable) |
| Oscillation Frequency | 0–200 cycles/min |
| Oscillation Amplitude | 8 mm |
| Pause Time Setting | 1 s–99 h |
| Forward/Reverse Cycle Timing | 1 s–99 h |
| Oscillation On/Off Timer | 0–30 min / 0–30 h / 0–300 h |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SER 158 |
| Extraction Type | Solid-Liquid |
| Max Temperature | 380 °C |
| Operating Pressure | Ambient |
| Extraction Cell Volume | 250 mL |
| Cycle Time | 130 min |
| Dimensions (W×H×D) | 358×546×450 mm (SER 158/3) / 546×546×450 mm (SER 158/6) |
| Sample Positions | 3 or 6 |
| Solvent Recovery Rate | >90% |
| RSD | ≤1% |
| Measurement Range | 0.1–100% |
| Power Supply | 115/230 V, 50/60 Hz |
| Power Consumption | 630/850 W |
| Cooling Water Flow | ≥1 L/min |
| Display | 7-inch color touchscreen |
| Connectivity | 3×USB, Ethernet, Ermes Cloud Platform |
| Compliance | ASTM D2231, ISO 14465, AOAC 920.39, USP <467>, EN 14082, NF T90-107 |
| Brand | Vigor |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | SPS |
| Pricing | Available Upon Request |
| Solvent Configurations | 3-, 5-, or 7-solvent modular units (customizable) |
| Purification Capacity per Unit | 800 L |
| Safety Integration | Compatible with flammable-solvent-rated safety cabinets |
| System Integration | Direct interface option with Vigor gloveboxes |
| Compliance Context | Designed for inert-atmosphere laboratory workflows requiring ultra-low H₂O/O₂ solvent handling (≤1 ppm H₂O, ≤1 ppm O₂ typical after regeneration) |
| Brand | Zhongyi Yusheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ASE-6 |
| Instrument Type | Solid-Liquid Extraction |
| Sample Throughput | 6 positions |
| Compliance | ASTM D7699, US EPA Method 3545A, ISO 14507, HJ 782–2016, HJ 783–2016, HJ 1290–2023, GB/T 23200.9–2016, GB/T 22996–2008, GB/T 23376–2009, SL 391–2007 |