Empowering Scientific Discovery

AdB Photonics Technology (China) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLTB
OriginGermany
ModelARYELLE200
Instrument TypeBenchtop
IntegrationFully Integrated
Laser Energy Range5 mJ – 850 mJ
Spectral Resolution (λ/Δλ)7,000 – 20,000 (practical)
Wavelength Coverage (single-shot, gap-free)200–750 nm (configurable options: 192–594 nm, 225–574 nm, 200–900 nm, 250–950 nm)
Slit Width45 µm (optional widths available)
Detector InterfaceSMA fiber coupling or free-space input
Spectral Sampling RateUp to 30 spectra/s
Detector OptionsICCD (1024 × 1024, 13 × 13 µm pixels), scientific cooled CCD/EMCCD/EMICCD
Minimum ICCD Gate Width5 ns (optional down to 0.5 ns)
ICCD Max Relative Gain1000
Dark Noise0.2 e⁻/pixel/sec
Full Well Capacity100,000 e⁻
Calibration SourceInternal Hg lamp with automated software-driven recalibration
NIST Emission Database IntegrationYes
Automatic Line IdentificationYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLTB
OriginGermany
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelARYELLE Butterfly
Price RangeUSD 135,000 – 162,000
Instrument TypeBenchtop
IntegrationIntegrated System
Laser Energy Range5 mJ – 850 mJ
Spectral Coverage190–950 nm (UV-VIS-NIR) + VUV extension via reflective optics
Spectral Resolution<20 pm @ 200 nm
Spectral Resolution Power>10,000 (practical, non-pixel-limited)
Detector Format1024 × 255 pixels, 26 × 26 µm, full-well capacity 1 Me⁻
Detector Cooling−70 °C thermoelectric
Optional DetectorsEMCCD or ICCD
Focal Length400 mm per channel
f-numberf/10
CalibrationAutomated wavelength recalibration using Hg lamp and internal shutter
Optical PathSMA-fiber-coupled for UV-VIS-NIR
Dual-Channel ArchitectureIndependent VUV and UV-VIS-NIR channels sharing one detector plane
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLTB
OriginGermany
ModelDEMON NIR Series
Form FactorBenchtop
IntegrationIntegrated Monolithic Design
Optical ConfigurationLittrow-Mounted Echelle Spectrometer with Dual Grating Architecture
Wavelength Range600–1700 nm
Spectral Resolution (λ/Δλ)>60,000 (e.g., <0.026 nm @ 1550 nm, <0.01 nm @ 600 nm, 0.011 nm @ 656 nm)
Linear Dispersionλ/90,000
Minimum Measurable FWHM≤0.014 nm @ 800 nm
Spectral Window2.5–8 nm (wavelength-dependent)
Detector InterfaceScientific-grade InGaAs area detector (16-bit)
Relative Aperturef/10
Minimum Exposure Time1 ms (CCD-compatible)
Stray Light LevelUltra-low (optimized Littrow echelle optical path)
Absolute Wavelength AccuracyPixel dispersion × 10 pixels
Active Wavelength StabilizationBuilt-in Hg reference lamp + automated self-calibration
Control InterfaceFull PC-based motorized control via USB/Ethernet
Dimensions (L×W×H)600 × 310 × 230 mm
Weight25 kg
Software PlatformSOPHI spectral acquisition & analysis suite (LabVIEW driver optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLTB
OriginGermany
ModelCORALIS
Instrument TypeBenchtop
IntegrationFully Integrated Dual-Modal Platform
LIBS Laser EnergyUp to 50 mJ (1064 nm, optionally 532 nm or 266 nm)
Raman Laser PowerUp to 50 mW (532 nm and 785 nm)
Spectral Coverage (LIBS)190–520 nm (scan-free)
Spectral Resolution (LIBS)0.013–0.035 nm
Spectral Coverage (Raman)530–950 nm (up to 6000 cm⁻¹)
Spectral Resolution (Raman)2.5–2.0 cm⁻¹ (532 nm), 1.7–1.4 cm⁻¹ (785 nm)
XYZ Stage TravelX=50 mm, Y=50 mm, Z=35 mm
Positioning Accuracy & Repeatability1 µm
Macro Imaging Field28 × 19 mm (10×)
Micro Imaging Field3.5 × 2.5 mm (80×)
Dimensions1200 × 750 × 750 mm
Laser Safety ClassClass 1
SoftwareFusionRL CORALIS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLTB
OriginGermany
ModelDEMON Series
Instrument TypeBenchtop
IntegrationIntegrated
Laser Energy Range5 mJ – 850 mJ
Wavelength Range175–1100 nm (configurable)
Spectral Resolutiondown to 1.34 pm @ 200 nm
Spectral Resolving Power75,000–200,000
Linear Dispersionλ/225,000
Absolute Wavelength Accuracy±0.25 pm (after auto-calibration)
Stray Light Level<10⁻⁶
Detector CompatibilityScientific CCD, ICCD, EMCCD, EMICCD
Slit ControlMotorized
ShutterIntegrated Mechanical
Exposure Time1 ms (CCD), 5 ns / 2 ns (ICCD)
InterfaceFull PC-based motorized control
Dimensions (L×W×H)750 × 310 × 230 mm
Weight25 kg
SoftwareSophi (with embedded NIST spectral database), LabVIEW driver optional
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLTB
OriginGermany
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelARYELLE400
Price RangeUSD 135,000–162,000 (est.)
Instrument TypeBenchtop
IntegrationFully Integrated
Laser Energy Range5 mJ – 850 mJ
Focal Length400 mm
Relative Aperturef/10
Spectral Resolution (practical)8 pm @ 192 nm (typical), down to 4 pm @ 192 nm (max)
Resolving Power (λ/Δλ)9,400–25,000 (typical), up to 50,000 (max, practical)
Wavelength Coverage (single acquisition)192–1090 nm (configurable subsets: 192–950 nm, 192–750 nm, etc.)
Slit Dimensions50 × 50 µm (custom widths available)
Detector CompatibilityPI/Andor CCD (2048 × 512 px
Timing Resolution100 ns minimum gate step (2 ns / 5 ns achievable with compatible detectors)
Dynamic Range15-bit system, 16-bit A/D conversion
Spectral CalibrationInternal Hg lamp + motorized shutter for automated recalibration
Spectral DatabaseNIST atomic emission line database with auto-line-matching algorithm
Optical CouplingMirror-based or fiber-optic (SMA connector)
Spectral AccuracyBetter than 1/4 of spectral resolution
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLTB
OriginGermany
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelLTB LIBSorter
Instrument TypeBenchtop
IntegrationIntegrated System
Laser Energy5 mJ – 850 mJ
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLTB
OriginGermany
ModelARYELLE150
Instrument TypeBenchtop
IntegrationIntegrated
Laser Energy Range5 mJ – 850 mJ
Spectral Resolution (λ/Δλ)6,000 – 15,000
Wavelength Coverage (Single Acquisition, No Scanning)200–600 nm (configurable options: 220–800 nm, 200–590 nm, 230–548 nm)
Slit Width35 µm (customizable)
Spectral Sampling RateUp to 30 spectra/s
Detector InterfaceFiber-coupled (SMA) or free-space
Calibration SourceIntegrated Hg lamp with automated wavelength recalibration
Spectral AccuracyBetter than 1/4 of spectral resolution
Detector OptionsEMCCD (1004 × 1002, 8 × 8 µm pixels), Scientific Cooled CCD or ICCD (application-dependent)
Dark Current0.06 e⁻/pixel/sec (@ −50 °C)
Full Well Capacity32,700 e⁻ (linear)
Max EMCCD Gain4000
Timing Resolution (LIBS gating)100 ns minimum step width
NIST Emission Database IntegrationYes
Automatic Spectral Line IdentificationYes
Added to wishlistRemoved from wishlist 0
Add to compare
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0