- All
- Favorite
- Popular
- Most rated
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | ARYELLE200 |
| Instrument Type | Benchtop |
| Integration | Fully Integrated |
| Laser Energy Range | 5 mJ – 850 mJ |
| Spectral Resolution (λ/Δλ) | 7,000 – 20,000 (practical) |
| Wavelength Coverage (single-shot, gap-free) | 200–750 nm (configurable options: 192–594 nm, 225–574 nm, 200–900 nm, 250–950 nm) |
| Slit Width | 45 µm (optional widths available) |
| Detector Interface | SMA fiber coupling or free-space input |
| Spectral Sampling Rate | Up to 30 spectra/s |
| Detector Options | ICCD (1024 × 1024, 13 × 13 µm pixels), scientific cooled CCD/EMCCD/EMICCD |
| Minimum ICCD Gate Width | 5 ns (optional down to 0.5 ns) |
| ICCD Max Relative Gain | 1000 |
| Dark Noise | 0.2 e⁻/pixel/sec |
| Full Well Capacity | 100,000 e⁻ |
| Calibration Source | Internal Hg lamp with automated software-driven recalibration |
| NIST Emission Database Integration | Yes |
| Automatic Line Identification | Yes |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ARYELLE Butterfly |
| Price Range | USD 135,000 – 162,000 |
| Instrument Type | Benchtop |
| Integration | Integrated System |
| Laser Energy Range | 5 mJ – 850 mJ |
| Spectral Coverage | 190–950 nm (UV-VIS-NIR) + VUV extension via reflective optics |
| Spectral Resolution | <20 pm @ 200 nm |
| Spectral Resolution Power | >10,000 (practical, non-pixel-limited) |
| Detector Format | 1024 × 255 pixels, 26 × 26 µm, full-well capacity 1 Me⁻ |
| Detector Cooling | −70 °C thermoelectric |
| Optional Detectors | EMCCD or ICCD |
| Focal Length | 400 mm per channel |
| f-number | f/10 |
| Calibration | Automated wavelength recalibration using Hg lamp and internal shutter |
| Optical Path | SMA-fiber-coupled for UV-VIS-NIR |
| Dual-Channel Architecture | Independent VUV and UV-VIS-NIR channels sharing one detector plane |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | DEMON NIR Series |
| Form Factor | Benchtop |
| Integration | Integrated Monolithic Design |
| Optical Configuration | Littrow-Mounted Echelle Spectrometer with Dual Grating Architecture |
| Wavelength Range | 600–1700 nm |
| Spectral Resolution (λ/Δλ) | >60,000 (e.g., <0.026 nm @ 1550 nm, <0.01 nm @ 600 nm, 0.011 nm @ 656 nm) |
| Linear Dispersion | λ/90,000 |
| Minimum Measurable FWHM | ≤0.014 nm @ 800 nm |
| Spectral Window | 2.5–8 nm (wavelength-dependent) |
| Detector Interface | Scientific-grade InGaAs area detector (16-bit) |
| Relative Aperture | f/10 |
| Minimum Exposure Time | 1 ms (CCD-compatible) |
| Stray Light Level | Ultra-low (optimized Littrow echelle optical path) |
| Absolute Wavelength Accuracy | Pixel dispersion × 10 pixels |
| Active Wavelength Stabilization | Built-in Hg reference lamp + automated self-calibration |
| Control Interface | Full PC-based motorized control via USB/Ethernet |
| Dimensions (L×W×H) | 600 × 310 × 230 mm |
| Weight | 25 kg |
| Software Platform | SOPHI spectral acquisition & analysis suite (LabVIEW driver optional) |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | CORALIS |
| Instrument Type | Benchtop |
| Integration | Fully Integrated Dual-Modal Platform |
| LIBS Laser Energy | Up to 50 mJ (1064 nm, optionally 532 nm or 266 nm) |
| Raman Laser Power | Up to 50 mW (532 nm and 785 nm) |
| Spectral Coverage (LIBS) | 190–520 nm (scan-free) |
| Spectral Resolution (LIBS) | 0.013–0.035 nm |
| Spectral Coverage (Raman) | 530–950 nm (up to 6000 cm⁻¹) |
| Spectral Resolution (Raman) | 2.5–2.0 cm⁻¹ (532 nm), 1.7–1.4 cm⁻¹ (785 nm) |
| XYZ Stage Travel | X=50 mm, Y=50 mm, Z=35 mm |
| Positioning Accuracy & Repeatability | 1 µm |
| Macro Imaging Field | 28 × 19 mm (10×) |
| Micro Imaging Field | 3.5 × 2.5 mm (80×) |
| Dimensions | 1200 × 750 × 750 mm |
| Laser Safety Class | Class 1 |
| Software | FusionRL CORALIS |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | DEMON Series |
| Instrument Type | Benchtop |
| Integration | Integrated |
| Laser Energy Range | 5 mJ – 850 mJ |
| Wavelength Range | 175–1100 nm (configurable) |
| Spectral Resolution | down to 1.34 pm @ 200 nm |
| Spectral Resolving Power | 75,000–200,000 |
| Linear Dispersion | λ/225,000 |
| Absolute Wavelength Accuracy | ±0.25 pm (after auto-calibration) |
| Stray Light Level | <10⁻⁶ |
| Detector Compatibility | Scientific CCD, ICCD, EMCCD, EMICCD |
| Slit Control | Motorized |
| Shutter | Integrated Mechanical |
| Exposure Time | 1 ms (CCD), 5 ns / 2 ns (ICCD) |
| Interface | Full PC-based motorized control |
| Dimensions (L×W×H) | 750 × 310 × 230 mm |
| Weight | 25 kg |
| Software | Sophi (with embedded NIST spectral database), LabVIEW driver optional |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ARYELLE400 |
| Price Range | USD 135,000–162,000 (est.) |
| Instrument Type | Benchtop |
| Integration | Fully Integrated |
| Laser Energy Range | 5 mJ – 850 mJ |
| Focal Length | 400 mm |
| Relative Aperture | f/10 |
| Spectral Resolution (practical) | 8 pm @ 192 nm (typical), down to 4 pm @ 192 nm (max) |
| Resolving Power (λ/Δλ) | 9,400–25,000 (typical), up to 50,000 (max, practical) |
| Wavelength Coverage (single acquisition) | 192–1090 nm (configurable subsets: 192–950 nm, 192–750 nm, etc.) |
| Slit Dimensions | 50 × 50 µm (custom widths available) |
| Detector Compatibility | PI/Andor CCD (2048 × 512 px |
| Timing Resolution | 100 ns minimum gate step (2 ns / 5 ns achievable with compatible detectors) |
| Dynamic Range | 15-bit system, 16-bit A/D conversion |
| Spectral Calibration | Internal Hg lamp + motorized shutter for automated recalibration |
| Spectral Database | NIST atomic emission line database with auto-line-matching algorithm |
| Optical Coupling | Mirror-based or fiber-optic (SMA connector) |
| Spectral Accuracy | Better than 1/4 of spectral resolution |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | LTB LIBSorter |
| Instrument Type | Benchtop |
| Integration | Integrated System |
| Laser Energy | 5 mJ – 850 mJ |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Model | ARYELLE150 |
| Instrument Type | Benchtop |
| Integration | Integrated |
| Laser Energy Range | 5 mJ – 850 mJ |
| Spectral Resolution (λ/Δλ) | 6,000 – 15,000 |
| Wavelength Coverage (Single Acquisition, No Scanning) | 200–600 nm (configurable options: 220–800 nm, 200–590 nm, 230–548 nm) |
| Slit Width | 35 µm (customizable) |
| Spectral Sampling Rate | Up to 30 spectra/s |
| Detector Interface | Fiber-coupled (SMA) or free-space |
| Calibration Source | Integrated Hg lamp with automated wavelength recalibration |
| Spectral Accuracy | Better than 1/4 of spectral resolution |
| Detector Options | EMCCD (1004 × 1002, 8 × 8 µm pixels), Scientific Cooled CCD or ICCD (application-dependent) |
| Dark Current | 0.06 e⁻/pixel/sec (@ −50 °C) |
| Full Well Capacity | 32,700 e⁻ (linear) |
| Max EMCCD Gain | 4000 |
| Timing Resolution (LIBS gating) | 100 ns minimum step width |
| NIST Emission Database Integration | Yes |
| Automatic Spectral Line Identification | Yes |
Show next