| Brand | Ailun (Qingdao Ailun) |
|---|---|
| Origin | Shandong, China |
| Model | GIC-YC9000 |
| Instrument Type | Online Aerosol and Gaseous Ion Analyzer |
| Liquid Sampling Resolution | 0.01 mL |
| Gas Absorption Efficiency | ≥98.2% |
| Aerosol Collection Efficiency | ≥99.1% |
| Measured Species | F⁻, Cl⁻, NO₃⁻, NO₂⁻, SO₄²⁻, Na⁺, NH₄⁺, K⁺, Mg²⁺, Ca²⁺, HF, HCl, HNO₂, HNO₃, SO₂, NH₃ |
| Brand | Airel |
|---|---|
| Model | VLDMA |
| Type | Differential Mobility Analyzer (DMA) |
| Maximum Particle Diameter | 8,000 nm |
| Upper Mobility Range | 1.2 × 10⁻⁶ cm²/V·s |
| High-Voltage Range | ±10 kV |
| Sheath Flow Rate | 2–20 L/min |
| Sheath-to-Sample Flow Ratio | 1:10 |
| Gravity Drift Compensation | Automated for particles >4 µm |
| Interface | RJ45, Ethernet (LAN) |
| Dimensions | 165 × 57 × 57 cm |
| Weight | Not specified |
| Compatibility | Airel Aerosol Electrometer Model 202 (native), third-party CPCs/SMPS systems (optional) |
| Control Software | Integrated DMA controller with step-scan and time-delay correction modes |
| Brand | Artium |
|---|---|
| Origin | USA |
| Model | PDI-FPDR |
| Instrument Type | Aerosol Detector |
| Application | Airborne Cloud Microphysics Measurement |
| Laser Source | Diode-Pumped Solid-State (DPSS) |
| Optical Configuration | Transmissive Dual-Beam Interferometric |
| Particle Discrimination | Spherical Liquid Droplets vs. Ice Crystals |
| Optional Feature | Integrated Anti-Icing Heater |
| Compliance Context | Designed for FAA Part 25/27-certified research aircraft integration and NASA GRC-validated flight test protocols |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 100X |
| Instrument Type | Aerosol Testing System |
| Compliance Standards | NIOSH 42 CFR Part 84, GB 2626, EN 13274-7:2019, ASTM F3502-21 |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 2i |
| Instrument Type | Aerosol Photometer |
| Price Range | USD $6,800 – $13,600 (est.) |
| Compliance | ISO 14644-3, NSF/ANSI 49, IEST-RP-CC034, EN 12469, CE, UKCA, EN 61010-1:2010, EN 61326-1:2006, FCC Part 15 Subpart B, ISED ICES-003 Issue 7 |
| Dimensions | 25.7 cm × 33 cm × 15.2 cm (10.1 in × 13 in × 6 in) |
| Weight | 8.6 kg (19 lbs) |
| Power Input | 100–250 V AC, 50/60 Hz auto-ranging |
| Flow Rate | 28.3 L/min ±10% (1 ft³/min) |
| Dynamic Range | 0.0001–120 mg/m³ |
| Sensitivity | ±1% of reading (0.01–100% range) |
| Repeatability | ±0.5% of reading (0.01–100% range) |
| Zeroing | Automatic at startup |
| Alarm | User-configurable audible, visual, and haptic |
| Aerosol Compatibility | PAO-4, DOP, DOS/DEHS, Ondina, PEG, Krydol, corn oil, mineral oil, paraffin |
| Data Output | Thermal printer, USB port |
| Data Storage | Up to 150,000 scan records (CSV + PDF) |
| Calibration System | ATI CALIBRA™ 800 aerosol generator with gravimetric traceability and multi-point linearity verification (patent-pending) |
| Software Compliance | 21 CFR Part 11–compliant audit trail, encrypted storage, password protection, electronic signatures (iProbe Plus only) |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | iProbe Plus |
| Instrument Type | Aerosol Detector |
| Compliance | IEC 60068-2-27 (Shock), IEC 60068-2-6 (Vibration), IEC 60068-2-14 (Temperature Cycling), IEC 60068-2-27 (Thermal Shock) |
| Operating Temperature Range | −20 °C to +70 °C |
| Data Storage Capacity | ~150,000 scans |
| Output Formats | CSV, PDF |
| Interface | USB-A port for data export and firmware update |
| Display | 4.3-inch color touchscreen |
| Valve Control | Integrated upstream/downstream/zero valve control via touchscreen |
| Security | Password protection, encrypted data storage, audit-trail compliant with FDA 21 CFR Part 11 |
| Ergonomics | Contoured grip with finger grooves and thumb rest |
| Unique Feature | 10-second “rewind” function (patent pending) |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Aerosol Black Carbon Analyzer |
| Measurement Principle | Optical Attenuation (Filter-Based Transmission) |
| Wavelength Channels | 7-channel (370, 450, 520, 590, 660, 880, 950 nm) |
| Primary Output | Black Carbon Mass Concentration (µg/m³) and Wavelength-Dependent Absorption Coefficient (Mm⁻¹) |
| Compliance | QX/T 68–2007 (China Meteorological Administration Standard) |
| Flow Control | Integrated Precision Mass Flow Controller |
| Detection System | Dual Photodetector Correction + Charge-Integrating ADC Architecture |
| Data Output | Real-time, Continuous, On-line |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | FPI (Original Equipment Manufacturer) |
| Instrument Type | Online Aerosol Organic Carbon/Elemental Carbon Analyzer |
| Measurement Principle | Thermal-Optical Transmittance (TOT) or Thermal-Optical Reflectance (TOR) |
| Compliance | Designed for ASTM D7520, IMPROVE_A, NIOSH 5040-compatible protocols |
| Sample Inlet | Standard PM2.5 or PM10 inlet with heated line (optional) |
| Detection Method | Laser transmittance/reflectance monitoring during thermal desorption |
| Flow Control | Proportional solenoid valves + mass flow controllers (MFCs) |
| Furnace Construction | High-purity alumina ceramic furnace bricks with ceramic fiber-insulated heating elements |
| OC/EC Split Point Determination | Automated optical carbon charring correction algorithm |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZR-1002 |
| Instrument Category | Aerosol Testing System |
| Compliance Standards | GB/T 6165–2008, GB 2626–2006, GB/T 32610–2016 |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZR-6012 |
| Instrument Type | Aerosol Photometer |
| Detection Principle | Mie Scattering |
| Concentration Range | 0.0001–700 μg/L |
| Compliance | JJF 1800–2020, ISO 14644-3:2005, GB 50073–2013, GB 50591–2010, YY 0569–2005, JJF 1815–2020, NSF/ANSI 49–2019 |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm AG (in collaboration with ECN & Applikon) |
| Model | MARGA 2S |
| Instrument Type | Online Continuous Monitor |
| Compliance | EPA ETV Verified |
| Software | MARGA Control Suite v5.x |
| Data Output | Real-time ion concentrations (µg/m³), hourly time resolution |
| Sample Streams | Simultaneous PM₂.₅, PM₁₀, gaseous HNO₃, HCl, NH₃, SO₂, HCOOH, CH₃COOH |
| Detection Principle | Wet-chemical absorption + Dual IC (Ion Chromatography) |
| Automation Level | Fully unattended operation up to 168 h |
| Remote Capability | Secure web-based monitoring, diagnostic access, and parameter control via TLS-encrypted interface |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MARS |
| Pricing | Upon Request |
| Brand | WD Precision |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SwisensPoleno Jupiter |
| Price | USD 420,000 (FOB Zurich) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | URG-9000 |
| Instrument Type | Aerosol and Gaseous Ion Monitor |
| Detection Principle | Dual-Channel Suppressed Ion Chromatography with Wet Parallel-Plate Denuder Sampling |
| Brand | TOPAS |
|---|---|
| Origin | Germany |
| Model | DDU-570 |
| Instrument Type | Aerosol Conditioning Device |
| Design Variants | High-Profile (DDU-570/H) and Low-Profile (DDU-570/L) |
| Desiccant | Indicating Silica Gel (Type 830 for DDU-570/H |
| Max. Inlet Aerosol Flow Rate | 10 L/min (H) / 5 L/min (L) |
| Max. Inlet Aerosol Temperature | 40 °C |
| Operating Ambient Temperature | ≤40 °C |
| Dimensions (d × H) | 70 × 475 mm (H) / 70 × 253 mm (L) |
| Hose Connection | Ø 8 mm |
| Weight (empty) | 0.94 kg (H) / 0.72 kg (L) |
| Compliance | Designed for ISO 27427-compliant aerosol generation systems |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8533EP |
| Instrument Type | Real-time Aerosol Mass Concentration Monitor |
| Detection Principle | 90° Light Scattering (Laser Photometry) |
| Mass Concentration Range | 0.001–150 mg/m³ |
| Simultaneous Size-Fractionated Outputs | PM₁, PM₂.₅, Respirable (PM₄), PM₁₀, and Total PM (<15 µm) |
| Flow Rate | 3.0 L/min (±5% accuracy, internally controlled) |
| Optical System | Sheath-Air Isolated Laser Cavity |
| Display | 5.7″ VGA Color Touchscreen |
| Data Storage | 5 MB internal memory (>60,000 data points |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–60 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Time Constant | User-selectable (1–60 s) |
| Resolution | ±0.1% of reading or 0.001 mg/m³ (whichever is greater) |
| Zero Stability | ±0.002 mg/m³ over 24 h |
| Particle Size Range | 0.1–15 µm |
| Power | Rechargeable Li-ion battery (2.0 kg w/1 battery |
| Connectivity | USB, Ethernet (8533EP only), USB mass storage support |
| Analog Output | User-selectable 0–5 V or 2–20 mA |
| Alarm Output | Relay (non-latching MOSFET) or audible buzzer |
| Filter Holder | Replaceable 37 mm filter cassette (user-supplied) |
| Compliance | Designed for use in occupational health monitoring per OSHA, NIOSH, and ISO 7708 air sampling protocols |