Aerosol Detectors
Filter
Showing 1–30 of 68 results
| Brand | Ailun (Qingdao Ailun) |
|---|---|
| Origin | Shandong, China |
| Model | GIC-YC9000 |
| Instrument Type | Online Aerosol and Gaseous Ion Analyzer |
| Liquid Sampling Resolution | 0.01 mL |
| Gas Absorption Efficiency | ≥98.2% |
| Aerosol Collection Efficiency | ≥99.1% |
| Measured Species | F⁻, Cl⁻, NO₃⁻, NO₂⁻, SO₄²⁻, Na⁺, NH₄⁺, K⁺, Mg²⁺, Ca²⁺, HF, HCl, HNO₂, HNO₃, SO₂, NH₃ |
| Brand | Airel |
|---|---|
| Model | VLDMA |
| Type | Differential Mobility Analyzer (DMA) |
| Maximum Particle Diameter | 8,000 nm |
| Upper Mobility Range | 1.2 × 10⁻⁶ cm²/V·s |
| High-Voltage Range | ±10 kV |
| Sheath Flow Rate | 2–20 L/min |
| Sheath-to-Sample Flow Ratio | 1:10 |
| Gravity Drift Compensation | Automated for particles >4 µm |
| Interface | RJ45, Ethernet (LAN) |
| Dimensions | 165 × 57 × 57 cm |
| Weight | Not specified |
| Compatibility | Airel Aerosol Electrometer Model 202 (native), third-party CPCs/SMPS systems (optional) |
| Control Software | Integrated DMA controller with step-scan and time-delay correction modes |
| Brand | Artium |
|---|---|
| Origin | USA |
| Model | PDI-FPDR |
| Instrument Type | Aerosol Detector |
| Application | Airborne Cloud Microphysics Measurement |
| Laser Source | Diode-Pumped Solid-State (DPSS) |
| Optical Configuration | Transmissive Dual-Beam Interferometric |
| Particle Discrimination | Spherical Liquid Droplets vs. Ice Crystals |
| Optional Feature | Integrated Anti-Icing Heater |
| Compliance Context | Designed for FAA Part 25/27-certified research aircraft integration and NASA GRC-validated flight test protocols |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 100X |
| Instrument Type | Aerosol Testing System |
| Compliance Standards | NIOSH 42 CFR Part 84, GB 2626, EN 13274-7:2019, ASTM F3502-21 |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 2i |
| Instrument Type | Aerosol Photometer |
| Price Range | USD $6,800 – $13,600 (est.) |
| Compliance | ISO 14644-3, NSF/ANSI 49, IEST-RP-CC034, EN 12469, CE, UKCA, EN 61010-1:2010, EN 61326-1:2006, FCC Part 15 Subpart B, ISED ICES-003 Issue 7 |
| Dimensions | 25.7 cm × 33 cm × 15.2 cm (10.1 in × 13 in × 6 in) |
| Weight | 8.6 kg (19 lbs) |
| Power Input | 100–250 V AC, 50/60 Hz auto-ranging |
| Flow Rate | 28.3 L/min ±10% (1 ft³/min) |
| Dynamic Range | 0.0001–120 mg/m³ |
| Sensitivity | ±1% of reading (0.01–100% range) |
| Repeatability | ±0.5% of reading (0.01–100% range) |
| Zeroing | Automatic at startup |
| Alarm | User-configurable audible, visual, and haptic |
| Aerosol Compatibility | PAO-4, DOP, DOS/DEHS, Ondina, PEG, Krydol, corn oil, mineral oil, paraffin |
| Data Output | Thermal printer, USB port |
| Data Storage | Up to 150,000 scan records (CSV + PDF) |
| Calibration System | ATI CALIBRA™ 800 aerosol generator with gravimetric traceability and multi-point linearity verification (patent-pending) |
| Software Compliance | 21 CFR Part 11–compliant audit trail, encrypted storage, password protection, electronic signatures (iProbe Plus only) |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | iProbe Plus |
| Instrument Type | Aerosol Detector |
| Compliance | IEC 60068-2-27 (Shock), IEC 60068-2-6 (Vibration), IEC 60068-2-14 (Temperature Cycling), IEC 60068-2-27 (Thermal Shock) |
| Operating Temperature Range | −20 °C to +70 °C |
| Data Storage Capacity | ~150,000 scans |
| Output Formats | CSV, PDF |
| Interface | USB-A port for data export and firmware update |
| Display | 4.3-inch color touchscreen |
| Valve Control | Integrated upstream/downstream/zero valve control via touchscreen |
| Security | Password protection, encrypted data storage, audit-trail compliant with FDA 21 CFR Part 11 |
| Ergonomics | Contoured grip with finger grooves and thumb rest |
| Unique Feature | 10-second “rewind” function (patent pending) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | BAMS-3000 |
| Price Range | USD $13,500 – $40,500 (FOB Shanghai) |
| Instrument Category | Real-Time Bioaerosol Detection System |
| Sampling Flow Rate | >200 L/min |
| Detection Sensitivity | ~5 genomic copies per reaction (adjustable) |
| Sample Processing Volume | 0–25 mL |
| Throughput | 92 samples |
| Analysis Time | <30 min per sample |
| Dimensions | 545 × 440 × 475 mm (L×W×H) |
| Power Supply | 220 V AC, 50 Hz |
| Compliance | GB/T 38517–2020, GB/T 39990–2021, GB/T 16293–2010, GB/T 16294–2010, GB/T 18204.3–2013 |
| Brand | Cimel |
|---|---|
| Origin | France |
| Model | CE318 |
| Instrument Type | Aerosol Optical Depth (AOD) & Sky Radiance Spectroradiometer |
| Standard Spectral Channels | 340, 380, 440, 500, 675, 870, 936, 1020, 1640 nm (FWHM ≤ 10 nm) |
| Field of View | 1.3° (full width at half maximum) |
| Detector Configuration | Enhanced silicon photodiode (direct sun), silicon photodiode (sky radiance) |
| Solar Tracking Accuracy | < 0.1° (dual-axis stepper motor + quadrant detector fine adjustment) |
| Operating Temperature Range | −30 °C to +60 °C |
| Power Supply | Internal battery (optical head), external battery (motor drive) |
| Data Interfaces | RS-232 serial, USB, optional Wi-Fi/3G/Geostationary Satellite (Meteosat/GOES/GMS) telemetry |
| Environmental Protection | Automatic rain shutdown via integrated hygrometer |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | CPR-KA |
| Pricing | Upon Request |
| Brand | EcoChem |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DC-2200CE |
| Instrument Type | Aerosol Detector |
| Power Supply | 15 V Rechargeable Li-ion Battery |
| Display | 2-line × 16-character LED |
| Weight | 1.5 kg |
| Dimensions | 68 mm × 175 mm × 124 mm |
| Operating Temperature | 5–40 °C |
| Storage Capacity | 8,000 data points (timestamp + surface area value) |
| Flow Rate | 1 LPM |
| Measurement Range | 0–1000 µm²/cm³ |
| Detection Limit | 0–10 µm²/cm³ |
| Sensitivity | 0–10 µm²/cm³ |
| Response Time | <10 s (adjustable) |
| Data Output | RS232 |
| Software Compatibility | PC-based charting utility with Excel export |
| Brand | EcoChem |
|---|---|
| Origin | USA |
| Model | PAS-2200CE |
| Instrument Type | Aerosol-Bound PAH Monitor |
| Detection Principle | UV Photoionization of Adsorbed PAHs |
| Measurement Range | 0–1000 ng/m³ |
| LOD | 10 ng/m³ (total adsorbed PAH) |
| Flow Rate | 1 L/min |
| Response Time | <10 s (adjustable) |
| Sensitivity | 10 ng/m³ |
| Operating Temperature | 5–40 °C |
| Data Storage | 8,000 points (timestamped) |
| Weight | 1.5 kg |
| Dimensions | 58 × 175 × 124 mm |
| Power | 15 V DC (rechargeable battery) or 220 V AC/50 Hz |
| Display | 2-line × 16-character LED |
| Output | RS232 serial interface |
| Data Logging | Embedded system (up to 2,500 records) |
| Brand | EcoChem |
|---|---|
| Origin | USA |
| Model | PAS2000 STD |
| Instrument Type | Aerosol Detector |
| Detection Principle | UV Photoionization of Particle-Bound Polycyclic Aromatic Hydrocarbons (PAHs) |
| Measurement Range | 0–100 µg/m³ (PAH), 0–100 µg/m³ (Elemental Carbon), 0–100 pA (Ion Current) |
| Detection Limit | 3 ng total adsorbed PAH |
| Sensitivity | 0.3–1 µg/m³ PAH per pA |
| Response Time | <10 s (adjustable) |
| Flow Rate | 2 LPM |
| Operating Temperature | 5–40 °C |
| Data Storage | 8,000 points (timestamped) |
| Display | 2×16-character LED |
| Output Interfaces | RS-232, 0–10 V, 0–20 mA, or 4–20 mA |
| Dimensions | 68 × 175 × 124 mm |
| Weight | 9 kg |
| Power Supply | 220 V AC / 50 Hz |
| Optional Heated Sampling Probe | 5–300 °C |
| Dilution Ratios | 0.05, 0.1, 0.2 (with mass flow controller and critical orifice) |
| Brand | EDC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PC-2HX |
| Instrument Type | Aerosol Size Distribution and Mass Concentration Analyzer |
| Measurement Principle | Inertial Impaction with QCM Gravimetric Detection |
| Size Range | 0.1–25 µm (10-stage cascade impactor configuration) |
| Flow Rate | 2.0 L/min (PC-2HX variant) |
| Mass Sensitivity | 1 ng/Hz |
| Detection Limit | ~5 µg/m³ (typical) |
| Minimum Detectable Particle Diameter | 100 nm |
| Output | Real-time size-resolved mass concentration (µg/m³ per stage), PM₁ / PM₂.₅ / PM₁₀ equivalent calculation, timestamped histogram export |
| Interface | RS-232 / USB to PC |
| Sample Substrate | Removable QCM crystals or aluminum collection plates for SEM/EDS analysis |
| Brand | EDC |
|---|---|
| Origin | USA |
| Model | DPM-4000 |
| Instrument Type | Aerosol Detector |
| Measurement Range | 1–20,000 µg/m³ |
| Resolution | ±2 µg/m³ |
| Accuracy | ±10% |
| Particle Size Range | <1–10 µm |
| Sampling Flow Rate | 1.0–3.3 L/min (recommended 1.7 L/min) |
| Display | 4-line × 20-character LCD (units: µg/m³, mg/m³, TWA, STEL, min/max) |
| Data Storage | 21,500 points (>5 years retention) |
| Logging Interval | 1 sec to 21 weeks |
| Alarm | 90 dB at 3 ft |
| Operating Temp | 0–50 °C |
| Storage Temp | −20–70 °C |
| Humidity | ≤95% RH non-condensing |
| Power | Rechargeable battery (>8 h runtime |
| Dimensions | 140 × 83 × 70 mm |
| Weight | 1.0 kg |
| Compliance | NIOSH 5040 compatible, NIST-traceable calibration support, OSHA-compliant exposure assessment |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Aerosol Black Carbon Analyzer |
| Measurement Principle | Optical Attenuation (Filter-Based Transmission) |
| Wavelength Channels | 7-channel (370, 450, 520, 590, 660, 880, 950 nm) |
| Primary Output | Black Carbon Mass Concentration (µg/m³) and Wavelength-Dependent Absorption Coefficient (Mm⁻¹) |
| Compliance | QX/T 68–2007 (China Meteorological Administration Standard) |
| Flow Control | Integrated Precision Mass Flow Controller |
| Detection System | Dual Photodetector Correction + Charge-Integrating ADC Architecture |
| Data Output | Real-time, Continuous, On-line |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | FPI (Original Equipment Manufacturer) |
| Instrument Type | Online Aerosol Organic Carbon/Elemental Carbon Analyzer |
| Measurement Principle | Thermal-Optical Transmittance (TOT) or Thermal-Optical Reflectance (TOR) |
| Compliance | Designed for ASTM D7520, IMPROVE_A, NIOSH 5040-compatible protocols |
| Sample Inlet | Standard PM2.5 or PM10 inlet with heated line (optional) |
| Detection Method | Laser transmittance/reflectance monitoring during thermal desorption |
| Flow Control | Proportional solenoid valves + mass flow controllers (MFCs) |
| Furnace Construction | High-purity alumina ceramic furnace bricks with ceramic fiber-insulated heating elements |
| OC/EC Split Point Determination | Automated optical carbon charring correction algorithm |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GB-KF30010E |
| Instrument Type | Aerosol Filtration Efficiency Tester |
| Filtration Efficiency Range | 0–99.999% |
| Aerosol Flow Rate | 10–100 L/min (Accuracy Class 2.5) |
| Sampling Frequency | 1–9999 times/min (adjustable) |
| Test Aerosol Concentration | 20–30 mg/m³ |
| Count Median Diameter (CMD) | NaCl aerosol (0.075 ± 0.02) µm |
| Geometric Standard Deviation (GSD) | NaCl ≤ 1.86 |
| Dynamic Detection Range | 0.001–100 mg/m³ (Accuracy: ±1%) |
| Differential Pressure Sensor Range | 0–500 Pa |
| Dimensions | 460 mm × 525 mm × 1430 mm |
| Power Supply | AC 220 V, 50 Hz |
| Environmental Requirements | 25 °C ± 5 °C, 30 %RH ± 10 %RH |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GB-KF30010R |
| Instrument Type | Aerosol Detector |
| A-Path Sampling Flow Rate | 28.3 L/min ±2.5% (Resolution: 0.1 L/min) |
| B-Path Sampling Flow Rate | 28.3 L/min ±2.5% (Resolution: 0.1 L/min) |
| Nebulizer Flow Rate | 8–10 L/min ±2.5% (Resolution: 0.1 L/min) |
| Peristaltic Pump Flow Rate | 0.006–3.0 mL/min ±2.5% (Resolution: 0.001 mL/min) |
| Pre-Flowmeter Pressure (A/B Path) | −20 to 0 kPa ±2.5% (Resolution: 0.01 kPa) |
| Pre-Nebulizer Pressure | 0–300 kPa ±2.5% (Resolution: 0.1 kPa) |
| Ambient Temperature Range | −40 to 99 °C ±2.5% (Resolution: 0.1 °C) |
| Aerosol Chamber Negative Pressure | −90 to −120 Pa ±2.0% (Resolution: 0.1 Pa) |
| Cabinet Negative Pressure Range | −50 to −200 Pa |
| Data Storage Capacity | >100,000 test records |
| Vortex Mixer | 8 × Φ16×150 mm tubes |
| HEPA Filter Efficiency | ≥99.99% for particles ≥0.3 µm |
| Aerosol Generator Output | Mass Median Diameter (MMD) = 3.0 ± 0.3 µm, Geometric Standard Deviation (GSD) ≤1.5 |
| Andersen Six-Stage Sampler Cut-Points | Stage I >7 µm, II: 4.7–7 µm, III: 3.3–4.7 µm, IV: 2.1–3.3 µm, V: 1.1–2.1 µm, VI: 0.6–1.1 µm |
| Aerosol Chamber Dimensions | 600 × 85 × 30 mm (L×D×H) |
| Positive Control Target | 2200 ± 500 CFU |
| Cabinet Ventilation Flow Rate | ≥5 m³/min |
| Cabinet Door Size | 1000 × 730 mm (W×D) |
| Main Unit Dimensions | 1180 × 650 × 1300 mm (W×D×H) |
| Adjustable Stand Dimensions | 1180 × 650 × 600 mm (H adjustable within ±10 cm) |
| Acoustic Noise Level | <65 dB(A) |
| Net Weight | ~150 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | <1500 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GB-KF30010Y |
| Instrument Type | Aerosol Filtration Efficiency Tester |
| Filtration Efficiency Range | 0–99.999% |
| Aerosol Flow Rate | 10–100 L/min (Accuracy Class 2.5) |
| Sampling Frequency | 1–9999 times/min (adjustable) |
| Test Aerosol Concentration | 20–30 mg/m³ |
| Count Median Diameter (CMD) | NaCl aerosol (0.075 ± 0.02) µm |
| Geometric Standard Deviation (GSD) | NaCl ≤ 1.86 |
| Dynamic Concentration Range | 0.001–100 mg/m³ (±1% accuracy) |
| Differential Pressure Sensor Range | 0–500 Pa |
| Dimensions | 460 mm × 525 mm × 1430 mm |
| Power Supply | AC 220 V, 50 Hz |
| Environmental Control | Temperature 25 °C ± 5 °C, Relative Humidity 30 %RH ± 10 %RH |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GB-KF30020 |
| Instrument Type | Aerosol Filtration Efficiency Tester |
| Filtration Efficiency Range | 0–99.999% |
| Aerosol Flow Rate | 10–100 L/min (Accuracy Class 2.5) |
| Sampling Frequency | 1–9999 times/min (adjustable) |
| Test Aerosol Concentration | 20–30 mg/m³ |
| Count Median Diameter (CMD) | NaCl aerosol (0.075 ± 0.02) µm |
| Geometric Standard Deviation (GSD) | NaCl ≤ 1.86 |
| Dynamic Concentration Range | 0.001–100 mg/m³ (±1% accuracy) |
| Differential Pressure Sensor Range | 0–500 Pa |
| Dimensions | 460 mm × 525 mm × 1430 mm |
| Power Supply | AC 220 V, 50 Hz |
| Environmental Requirements | 25 °C ± 5 °C, 30 %RH ± 10 %RH |
| Brand | GBPI |
|---|---|
| Model | GB-XF1000D |
| Instrument Type | Aerosol-Based Bacterial Filtration Efficiency Tester |
| Origin | Guangdong, China |
| Manufacturer | Guangzhou GBPI Packaging Testing Instruments Co., Ltd. |
| Compliance | YY 0469–2004, YY/T 0969–2013, ASTM F2100, ASTM F2101, EN 14683 |
| Sampling Method | Dual-Channel Parallel Andersen Cascade Impactor (6-Stage) |
| Aerosol Generation | Monodisperse *Staphylococcus aureus* Bioaerosol (MMAD: 3.0 ± 0.3 µm, GSD ≤ 1.5) |
| Flow Rate (A/B) | 28.3 L/min ±2.5% |
| Spray Flow | 8–10 L/min ±2.5% |
| Peristaltic Pump Flow | 0.006–3.0 mL/min ±2.5% |
| Pressure Control Range | –20 to 300 kPa ±2.5% |
| Aerosol Chamber Negative Pressure | –90 to –120 Pa ±2.0% |
| Cabinet Negative Pressure | –50 to –200 Pa |
| Temperature Measurement Range | –40 to 99 °C ±2.5% |
| Data Storage Capacity | >100,000 test records |
| Display | 10.4″ Industrial Touchscreen |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max Power Consumption | <1500 W |
| Noise Level | <65 dB(A) |
| Net Weight | ~150 kg |
| Dimensions (Main Unit) | 1180 × 650 × 1300 mm (W×D×H) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GB-XF1000S |
| Instrument Category | Aerosol Detector |
| Price Range | USD 14,000 – 42,000 (based on exchange rate ~¥100,000–¥300,000) |
| Compliance Standards | YY 0469–2004, YY/T 0969–2013, ASTM F2100, ASTM F2101, EN 14683 |
| Brand | GBPI |
|---|---|
| Model | GB-XF1000T |
| Instrument Type | Aerosol Detector |
| Origin | Guangdong, China |
| Manufacturer | Guangzhou GBPI Packaging Testing Instruments Co., Ltd. |
| Compliance | YY 0469–2004, YY/T 0969–2013, ASTM F2100, ASTM F2101, EN 14683 |
| Sampling Method | Dual-channel parallel Andersen cascade impactor (6-stage) with simultaneous control of A/B flow paths |
| Aerosol Generation | Microbial aerosol generator with mass median aerodynamic diameter (MMAD) = 3.0 ± 0.3 µm, GSD ≤ 1.5 |
| Flow Rate (A/B) | 28.3 L/min ±2.5% (resolution: 0.1 L/min) |
| Nebulizer Flow | 8–10 L/min ±2.5% (resolution: 0.1 L/min) |
| Peristaltic Pump Flow | 0.006–3.0 mL/min ±2.5% (resolution: 0.001 mL/min) |
| Pressure Monitoring | Upstream pressure (–20 to 0 kPa),雾室 negative pressure (–90 to –120 Pa), cabinet negative pressure (–50 to –200 Pa), all ±2.0–2.5% accuracy |
| Temperature Range | –40 to 99 °C (±2.5%) |
| Aerosol Chamber | 600 mm × 85 mm Ø × 30 mm |
| Positive Control | 2200 ± 500 CFU total viable count |
| Cabinet Airflow | ≥5 m³/min |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | <1500 W |
| Net Weight | ~150 kg |
| Dimensions (main unit) | 1180 × 650 × 1300 mm (W×D×H) |
| Adjustable Stand Height | ±100 mm |
| Data Storage Capacity | >100,000 test records |
| Display | 10.4″ industrial-grade high-brightness TFT touchscreen |
| Interface | USB port for data export via U-disk |
| Safety Features | Interlocked negative-pressure cabinet, built-in leakage protection, flame-retardant insulation, front-access tempered glass door, LED internal lighting |
| Filter Efficiency | ≥99.99% for particles ≥0.3 µm (HEPA) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XF-10010Q |
| Instrument Category | Aerosol Detector |
| Sampling Flow Rate (A/B) | 28.3 L/min ±2.5% |
| Nebulizer Flow Rate | (8–10) L/min ±2.5% |
| Peristaltic Pump Flow Range | (0.006–3.0) mL/min ±2.5% |
| Pressure Measurement Accuracy | ±2.5% (except aerosol chamber: ±2.0%) |
| Aerosol MMAD | 3.0 ± 0.3 µm, GSD ≤1.5 |
| Andersen Cascade Impactor Stages | 6-stage (I–VI), cutpoints: >7, 4.7–7, 3.3–4.7, 2.1–3.3, 1.1–2.1, 0.6–1.1 µm |
| Aerosol Chamber Dimensions | 600 × 85 × 30 mm (Lר×T) |
| Cabinet Negative Pressure | –50 to –200 Pa |
| Aerosol Chamber Negative Pressure | –90 to –120 Pa |
| Temperature Range | –40 to 99 °C ±2.5% |
| Data Storage Capacity | >100,000 test records |
| HEPA Filter Efficiency | ≥99.99% @ ≥0.3 µm |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | <1500 W |
| Net Weight | ~150 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XF-10010 |
| Instrument Type | Aerosol Detector |
| A-Path Sampling Flow | 28.3 L/min ±2.5% (0.1 L/min resolution) |
| B-Path Sampling Flow | 28.3 L/min ±2.5% (0.1 L/min resolution) |
| Nebulizer Flow | (8–10) L/min ±2.5% (0.1 L/min resolution) |
| Peristaltic Pump Flow | (0.006–3.0) mL/min ±2.5% (0.001 mL/min resolution) |
| Pressure Before A/B Flowmeters | (−20–0) kPa ±2.5% (0.01 kPa resolution) |
| Pressure Before Nebulizer | (0–300) kPa ±2.5% (0.1 kPa resolution) |
| Ambient Temperature Range | (−40–99) °C ±2.5% (0.1 °C resolution) |
| Aerosol Chamber Negative Pressure | (−90–−120) Pa ±2.0% (0.1 Pa resolution) |
| Cabinet Negative Pressure | −50 to −200 Pa |
| Data Storage Capacity | >100,000 test records |
| Vortex Mixer | 8 × Φ16×150 mm tubes |
| HEPA Filter Efficiency | ≥99.99% for particles ≥0.3 µm |
| Aerosol Generator MMAD | 3.0 ± 0.3 µm, GSD ≤1.5 |
| Andersen Six-Stage Impactor Cut Points | Stage I >7 µm, II: 4.7–7 µm, III: 3.3–4.7 µm, IV: 2.1–3.3 µm, V: 1.1–2.1 µm, VI: 0.6–1.1 µm |
| Aerosol Chamber Dimensions | 60 cm (L) × 8.5 cm (Ø) × 3 cm (T) |
| Positive Control Target | 2200 ± 500 CFU |
| Cabinet Ventilation Flow Rate | ≥5 m³/min |
| Cabinet Door Size | W1000 × D730 mm |
| Main Unit Dimensions | W1180 × D650 × H1300 mm |
| Adjustable Stand Dimensions | W1180 × D650 × H600 mm (±10 cm height adjustment) |
| Noise Level | <65 dB(A) |
| Weight | ~150 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | <1500 W |
| Brand | GRIMM |
|---|---|
| Origin | Germany |
| Model | DMA |
| Instrument Type | Aerosol Detector |
| Particle Size Range (L-DMA) | 5–350 nm (3.0 L/min sheath flow) / 10–1100 nm (20 L/min sheath flow) |
| Sheath Gas Flow | 3.0 L/min (standard), up to 150 L/min (high-flow variant) |
| Sample Flow | 0.3 L/min |
| High-Voltage Output | +5 to +10,000 V (positive inner electrode), negative polarity optional |
| Resolution | Up to 256 size channels |
| Operating Temperature | 10–35 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Power Supply | 85–264 VAC |
| Communication | RS-232 (9-pin D-sub), ASCII protocol, 4 MB PCMCIA SRAM |
| Working Fluid | Reagent-grade 1-Butanol |
| Safety | Automatic HV shutdown upon housing opening |
| Compliance | Designed for ISO 27498, ASTM D6243, and EU PM2.5/PM10 monitoring frameworks |
| Brand | GRIMM |
|---|---|
| Origin | Germany |
| Model | ESS |
| Instrument Type | Aerosol Sampling and Dilution System |
| Sample Gas Max Temperature | 500 °C |
| Probe Outer Diameter | 8 mm |
| Hot Dilution Air Flow Rate | 9 L/min (per stage) |
| Cold Dilution Air Flow Rate | 9 L/min |
| Primary Dilution Ratio (SMPS+E mode, 1 L/min sample flow) | 1:10 |
| Secondary Dilution Ratio (SMPS+E mode, 1 L/min sample flow) | 1:10 |
| Total Dilution Ratio (SMPS+E mode, 1 L/min sample flow) | 1:100 |
| Primary Dilution Ratio (SMPS+E mode, 0.3 L/min sample flow) | 1:31 |
| Secondary Dilution Ratio (SMPS+E mode, 0.3 L/min sample flow) | 1:31 |
| Total Dilution Ratio (SMPS+E mode, 0.3 L/min sample flow) | 1:961 |
| Heater Max Temperature | 200 °C |
| Pressure Tolerance | ±100 mbar (vs. ambient) |
| Dilution Air Specification | Particle-free, hydrocarbon-free, dry |
| Brand | GRIMM |
|---|---|
| Country of Origin | Germany |
| Model | FCE |
| Instrument Type | Aerosol Detector |
| Voltage Range | 0–10,000 V (user-selectable polarity) |
| Flow Rate | 0.3–5 L/min (external pump required) |
| Electrode Diameter | 10 mm or 20 mm (magnetically mounted) |
| Substrate Compatibility | Conductive or non-conductive sampling substrates |
| Particle Size Range | 0.8–1100 nm (when coupled with GRIMM DMA systems) |
| Dimensions | Ø126 mm × H264 mm |
| Weight | 3.3 kg |
| Power Supply | 100–240 VAC, 50–60 Hz or 12–18 VDC |
| Operating Temperature | 10–40 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Status Indication | LED indicators |
| Brand | GRIMM |
|---|---|
| Origin | Germany |
| Model | UF-CPC |
| Instrument Type | Aerosol Detector |
| Particle Size Range | 5 nm – 10,000 nm |
| Concentration Range (UF-CPC 100) | ≤ 20,000 P/cm³ (single-particle counting), < 10⁷ P/cm³ (photometric mode) |
| Concentration Range (UF-CPC 200) | ≤ 1,000,000 P/cm³ (single-particle counting), < 10⁷ P/cm³ (photometric mode) |
| Concentration Accuracy | ±5% (single counting), ±10% (photometric mode) |
| Response Time (t₉₀) | 3 s |
| Working Fluids | Butanol, Isopropanol, or Water |
| Aerosol Flow Rate | 0.30–0.60 L/min |
| Signal Processing | 20 MHz detection rate, 256 raw data channels |
| Embedded OS | Intel Atom™ 1.6 GHz processor, 2 GB CompactFlash, 800 × 480 touchscreen display |
| Connectivity | USB, Ethernet, RS232/RS485 |
| Power Supply | 115/230 V AC, 50/60 Hz |
| Dimensions (H×W×D) | 33 × 38 × 24 cm |
| Weight | 10 kg |
| Brand | Hund |
|---|---|
| Origin | Germany |
| Model | BAA500e |
| Instrument Type | Aerosol Detector |
| Pollen Identification Capacity | 40+ species (expandable) |
| Accuracy | >90% |
| Sensitivity | 1 particle/m³ |
| Particle Size Range | 10–150 µm |
| Sampling Flow Rate | 1117 L/min |
| Dimensions | 900 mm × 700 mm × 1800 mm |
| Weight | ≤400 kg |
| Power Supply | 230 V AC / max. 3.7 kW |
| Operating Temperature | −20 °C to +40 °C |
| Relative Humidity | 0–100% RH |
| Sampling Interval | 1–3 h |
| Autonomous Operation Duration | 2–4 weeks |
| Sample Carrier Capacity | Reusable magazine-style cassette (8–24 carriers/day) |