| Brand | Zhongke Duling (Duling) |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MCP-170H |
| Temperature Control Range & Accuracy | +3°C to 55°C, <±0.1°C |
| Temperature Uniformity | ≤±0.3°C |
| Humidity Control Range & Accuracy | 91–94% RH |
| Chamber Volume | 170 L |
| CO₂ Concentration Range | 0–20% |
| CO₂ Control Accuracy | ±0.1% |
| Heating Method | Direct-heating Air-jacketed |
| Humidification | Integrated 3-L Water Reservoir |
| Sterilization | 180°C Dry-Heat |
| Max Power Consumption | 1100 W |
| Interior Material | Electropolished Stainless Steel |
| Standard Shelves | 3 (max. 7 optional) |
| Shelf Load Capacity | 12 kg per shelf |
| Alarm Functions | Ambient Temp, Chamber Temp, CO₂ Level, Water Level |
| Brand | Duling |
|---|---|
| Origin | Anhui, China |
| Model | MCP-170G |
| Chamber Volume | 170 L |
| External Dimensions (W×D×H) | 670 × 825 × 920 mm |
| Internal Dimensions (W×D×H) | 490.5 × 560 × 620.5 mm |
| Temperature Range | Ambient +5°C to 55°C |
| Temperature Uniformity | ≤ ±0.3°C |
| Temperature Control Accuracy | < ±0.1°C |
| CO₂ Range | 0–20% |
| CO₂ Control Accuracy | ±0.1% |
| O₂ Range | 1–20.7% |
| O₂ Control Accuracy | ±0.5% |
| O₂ Sensor Type | Zirconia-based |
| CO₂ Sensor Type | Infrared (IR) |
| Humidification | Integrated 3-L Water Reservoir |
| Heating Method | Direct-heated Air Jacket |
| HEPA Filtration | ISO Class 5 (100) recovery in ≤5 min after 30-sec door opening |
| Max. Power Consumption | 1100 W |
| Shelf Load Capacity | 12 kg per shelf |
| Standard Shelves | 3 (up to 7 optional) |
| Shelf Sizes | 450 × 485 mm (large), 450 × 440 mm (small) |
| Alarm Functions | Ambient temperature, chamber temperature, CO₂/O₂ concentration, water level |
| O₂ Recovery Time (after 30-sec door opening) | 50 min (from 1.0% target), 25 min (from 5.0% target) |
| Brand | Duling |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MCP-170 |
| Temperature Range & Accuracy | +3 to 55 °C (±0.1 °C setpoint stability) |
| Temperature Uniformity | ≤ ±0.3 °C (at 37 °C, measured at 9 points per IEC 61000-4-2 compliant validation protocol) |
| Humidity Range & Control | 91–94% RH (with active humidity recovery <15 min after door opening) |
| Chamber Capacity | 170 L |
| Sterilization Method | 180 °C dry-heat chamber sterilization |
| Chamber Material | Electropolished 316L stainless steel interior |
| CO₂ Control | NDIR sensor with ±0.1% CO₂ accuracy, 0–20% range, PID-controlled gas injection |