Automatic Potentiometric Titrator
Filter
Showing 1–30 of 77 results
| Brand | BRAND® |
|---|---|
| Origin | Germany |
| Model | 4760161 |
| Measurement Range | 0.2–10 mL |
| Meter Accuracy | ±0.1% |
| Meter Resolution | 0.001 mL |
| Dispensing Accuracy | ≤±0.2% |
| Dispensing Resolution | 0.001 mL |
| Compliance | DIN EN ISO 385 (Class A volumetric accuracy) |
| Brand | Chengyi (scchengyi) |
|---|---|
| Origin | Sichuan, China |
| Model | CZD-1 |
| Measurement Range | pH 0.00–14.00 |
| Accuracy | ±0.06 pH (pH measurement), ±0.2% (volumetric repeatability) |
| Resolution | 0.01 pH / 1 mV |
| Stability | ±0.01 pH per 3 h |
| Endpoint Setting Range | 0.00–14.00 pH or ±1400 mV |
| Control Sensitivity | ±0.1 pH / ±5 mV |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 10 W |
| Net Weight | 5 kg |
| Environmental Operating Conditions | 5–40 °C, ≤85% RH |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-D1 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Potential Range | −2000 to +2000 mV |
| Potential Resolution | 0.1 mV |
| Titration Precision | ±5 µL (for 10 mL burette) |
| Potential Resolution (display) | 0.1 mV |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| Temperature Range | −5 to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Repeatability | ≤0.2% |
| Maximum Error | ≤±1.5% |
| Burette Options | 10 mL (±5 µL), 20 mL (±10 µL) |
| Operating System | Android 10 |
| Display | 7-inch capacitive touchscreen |
| Data Storage Capacity | 100,000 records |
| Connectivity | USB, Wi-Fi, Ethernet |
| Dimensions | 310 × 226 × 233 mm |
| Weight | 3.7 kg |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| Potential Measurement Range | −2000 to +2000 mV |
| Potential Resolution | 0.1 mV |
| Titration Precision | ±5 µL (for 10 mL burette) |
| Potential Display Resolution | 0.1 mV |
| Compliance | JJG 814–2015 Class 0.05 (Max. Indication Error: ±1.5% |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| Conductivity Range | 0.00 µS/cm–2000 mS/cm |
| Temperature Range | −5 to 105 °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.2 °C |
| Operating System | Android 10 |
| Display | 7-inch capacitive touchscreen |
| Data Storage | ≥100,000 records |
| Connectivity | USB, Wi-Fi, Ethernet |
| Dimensions | 310 × 226 × 233 mm |
| Weight | 3.7 kg |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-D3 |
| Instrument Type | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal Laboratory Use |
| Potential Range | −2000 to +2000 mV |
| Potential Resolution | 0.1 mV |
| Titration Accuracy | ±5 µL (for 10 mL burette) |
| Potential Basic Error | ±0.25 ‰/FS |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| Temperature Range | −5 to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Data Storage Capacity | 100,000 records |
| Operating System | Android 10 |
| Display | 7-inch capacitive touchscreen |
| Connectivity | USB, Wi-Fi, Ethernet |
| Dimensions | 310 × 226 × 233 mm |
| Weight | 3.7 kg |
| Brand | COMECAUSE |
|---|---|
| Model | IN-D4 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| Potential Measurement Range | −2000 to +2000 mV |
| Potential Resolution | 0.1 mV |
| Potential Accuracy | ±0.25 ‰ of full scale |
| Potential Stability | ±0.3 mV / 3 h |
| Titration Precision | ±5 µL (for 10 mL burette) |
| Titration Resolution | 0.1 mV |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| Conductivity Range | 0.00 µS/cm – 2000 mS/cm |
| Conductivity Accuracy | ±1.0 % FS |
| Temperature Range | −5 °C to +105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Display | 7-inch Android 10 touchscreen |
| Data Storage | 100,000 records |
| Connectivity | USB / Wi-Fi / Ethernet |
| Dimensions | 310 × 226 × 233 mm |
| Weight | 3.7 kg |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | APT300 |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Measurement Range | 0 to ±1999 mV, 0 to 14.00 pH |
| Accuracy | 0.1% F.S. (mV), ±0.01 pH |
| Control Precision | ±0.03 pH, ±3 mV |
| Input Impedance | >10¹² Ω |
| Operating Temperature | 5–40 °C |
| Relative Humidity | <85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 20 W |
| Weight | 6 kg |
| Brand | DoctorWater |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Dr-W1000 |
| Instrument Type | Universal Automatic Potentiometric Titrator |
| Application Scope | General-purpose |
| Titration Accuracy | ≤0.01 mL |
| Titration Resolution | 0.01 mL |
| Burette Capacity Options | 10 mL / 25 mL |
| Maximum Error | ±0.05% |
| Liquid Handling | Medical-grade precision syringe pump |
| Mixing Method | Magnetic stirring |
| Display | 7-inch HD capacitive touchscreen |
| Interface Language | Default Chinese, optional English firmware |
| Data Storage | 10,000 test records with timestamp, operator ID, and location metadata |
| Built-in Thermal Printer | Yes |
| Operating Environment | 5–40 °C, RH <85% (non-condensing) |
| Power Supply | AC 100–240 V input, DC 24 V output |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SUPEC 5500 |
| Pricing | Available Upon Request |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-100 |
| Instrument Type | General-purpose Automatic Potentiometric Titrator |
| Application Scope | General-purpose |
| Measurement Range | (-2000.0 to +2000.0) mV, (0.00 to 14.00) pH |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | 1 mV (mV mode), 0.01 pH (pH mode) |
| Titration Accuracy | (±0.3 mV ±1 digit) over 3 h |
| Input Impedance | ≥10¹⁵ Ω |
| Temperature Range (with optional thermostat) | -15 °C to +85 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy (optional) | ±0.5 °C |
| Minimum Dispense Volume | 0.02 mL |
| Titration Control Precision | ±0.01 mL |
| Measurement Modes | Dynamic titration, Equivalence-point titration, Fixed-volume titration, Direct pH measurement |
| Interface Options | RS232C, Printer port (for optional thermal mini-printer) |
| Data Output | Real-time titration curve plotting, PC connectivity for process monitoring and post-analysis |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-3D |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Potential Measurement Range | 0–2000 mV |
| Meter Accuracy | ±0.1 mV |
| Meter Resolution | 0.1 mV |
| Titration Accuracy | ±0.2 mV or ±0.1% of reading |
| Titration Resolution | 1/100,000 |
| Temperature Control | PID with dynamic compensation, external heating/cooling interface |
| Display | Large backlit Chinese LCD |
| Communication | RS-232 serial interface |
| Software Platform | Windows-based monitoring software |
| Titration System | Piston-driven burette with anti-diffusion titration tip |
| Burette Mounting | Push-in modular design |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | −1999.0 to +1999.0 mV |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | 1 mV (mV mode) |
| Titration Accuracy | ±0.3 mV ±1 digit over 3 h |
| Titration Resolution | 1/20000 |
| Regulatory Compliance | Certified per JJG 814–2015 (Chinese National Metrological Verification Regulation), GMP-compliant design |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-400 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measuring Range | mV: −2000 to +2000 mV |
| pH | 0.00 to 20.00 |
| Temperature | 0.0 to 125.0 °C |
| Resolution | pH: 0.01 |
| mV | 0.1 mV |
| Temperature | 0.1 °C |
| Input Current (Typical) | −3 × 10⁻¹⁵ A |
| Accuracy (mV) | ±0.5 mV |
| Minimum Dispensing Volume | 0.0625 µL |
| Titration Modes | Dynamic, Equivalence-point, Fixed-volume, pH-stat, and Direct pH Measurement |
| Method Storage Capacity | 30 pre-programmed titration methods |
| Result Storage Capacity | 100 titration records |
| Display & Interface | Dual-language (Chinese/English) LCD interface |
| Software | Embedded titration monitoring software with firmware update capability |
| Compliance Support | GLP/GMP-compliant data output and audit trail generation |
| Titration Precision | ±0.01 pH over 3 h |
| Titration Resolution | 1/20000 |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-600 |
| Measurement Range | ±2400 mV / ±20 pH |
| Meter Accuracy | 0.01 mV / 0.001 pH |
| Meter Resolution | 0.01 mV / 0.001 pH |
| Titration Accuracy | ±10 µL (at 10 mL) |
| Titration Resolution | 1/20000 |
| Overall Accuracy | ±0.1% |
| Precision | ≤0.1% |
| Input Impedance | ≥3×10¹² Ω |
| Input Current | ≤1×10⁻¹² A |
| Temperature Range | 0–125 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Humidity Range | 10–85% RH |
| Humidity Resolution | 1% RH |
| Humidity Accuracy | ±5% RH |
| Titration Speed | 1–99 mL/min (adjustable) |
| Titration Tube Mounting | Tool-free replacement |
| Brand | Hanna Instruments |
|---|---|
| Model | HI932 |
| Instrument Type | Universal Potentiometric Titrator |
| pH Range | –2.000 to 20.000 (selectable resolution: 0.001 / 0.01 / 0.1 pH) |
| mV Range | –2000.0 to 2000.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1 mV (@25°C) |
| ISE Range | 1×10⁻⁶ to 9.99×10¹⁰ |
| ISE Accuracy | ±0.5% (monovalent), ±1% (divalent) |
| Temperature Range | –5.0 to 105.0 °C |
| Temperature Accuracy | ±0.1 °C (@25°C, excluding probe error) |
| Burette Resolution | 1/40000 |
| Dispensing Accuracy | ±0.1% of full burette volume |
| Display | 5.7″ color LCD (320 × 240 px) |
| GLP Compliance | Full audit trail, timestamped method & result storage, user access control |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AT-1 Advanced |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | mV: −2000 to +2000 mV |
| pH | 0.000–14.000 |
| Temperature | −55 to +125 °C |
| Meter Accuracy | ±0.5% of full scale |
| Meter Resolution | 0.1 mV |
| Titration Precision | 0.8 mV/h |
| Input Impedance | >1 × 10¹² Ω |
| Bias Current | <1 × 10⁻¹² A |
| Titration Volume Resolution | 1 µL (with 20 mL burette) |
| Electrode Interfaces | Composite, Reference, Indicator, and Temperature Electrode Ports |
| GLP Compliance | User authentication, audit trail, electrode & titrant logging, PDF report export, method versioning |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | MT-V6 Redox |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| pH Measurement Range | 0.000–14.000, Resolution: 0.001 pH |
| Meter Accuracy | ±0.1 mV |
| Meter Resolution | 0.1 mV |
| Burette Precision | 20 mL standard burette / 1 µL, 10 mL optional burette / 0.5 µL |
| Potential Range | ±2000 mV, Resolution: 0.1 mV |
| Brand | Lasertec |
|---|---|
| Origin | Japan |
| Model | GT-200 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Specialized (e.g., Acid Number Determination in Gasoline) |
| Display | 5.7-inch Color LCD |
| Connectivity | USB, RS-232 (COM), GLP-compliant Data Logging |
| Software | Titration Viewer TV-200 |
| Automation Capacity | Up to 12 burettes + 24-position autosampler |
| Endpoint Detection | Smart End Point Detection (S.E.D.) Algorithm |
| Compliance | GLP Support (Calibration Traceability, User Access Levels, Audit Trail) |
| Brand | Leichi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ZDCL-1 |
| Instrument Category | General-Purpose Potentiometric Titrator |
| Application Scope | Dedicated for Chloride Ion Analysis |
| Measurement Range | (−1800.0 to +1800.0) mV |
| Meter Accuracy | ±0.20% of full scale |
| Meter Resolution | 0.1 mV |
| Titration Accuracy | (±0.3 mV ±1 digit) over 3 h |
| Titration Resolution | 1/10000 |
| Titration Repeatability | 0.20% |
| Burette Error | ±0.025 mL (10 mL burette), ±0.035 mL (20 mL burette) |
| Electronic Unit Basic Error | ±0.05% FS |
| Stability | ±0.3 mV / 3 h |
| Operating Environment | 0–40 °C, ≤85% RH |
| Dimensions & Weight | 340 × 400 × 400 mm, ~10 kg |
| Power Supply | AC (220 ± 22) V, (50 ± 1) Hz |
| Brand | Leichi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ZDJ-4D |
| Instrument Category | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | mV: −2000.0 to +2000.0 mV |
| pH | −5.000 to 20.000 |
| Potentiometric Resolution | 0.01 mV |
| Titration Volume Resolution | 1/20000 |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | SR-1 Robotic Autosampler + ZDJ-6 Titration Unit |
| Application Scope | General-purpose potentiometric titration |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ZDCL-2 |
| Instrument Category | General-Purpose Potentiometric Titrator |
| Application Specificity | Dedicated for Chloride Ion Analysis |
| Measurement Range | (−1800.0 to +1800.0) mV |
| Meter Accuracy | ±0.20% of full scale |
| Meter Resolution | 0.1 mV |
| Titration Accuracy | (±0.3 mV ±1 digit) over 3 hours |
| Titration Resolution | 1/10,000 |
| Titration Repeatability | ≤0.20% |
| Burette Error | ±0.025 mL (10 mL burette), ±0.035 mL (20 mL burette) |
| Stability | ±0.3 mV / 3 h |
| Operating Environment | 0–40 °C, ≤85% RH |
| Dimensions & Weight | 340 × 400 × 400 mm, ~10 kg |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ZDJ-3A |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | (−1999 to +1999) mV, (0.00 to 14.00) pH |
| Meter Accuracy | ±0.3% of full scale |
| Meter Resolution | 1 mV, 0.01 pH |
| Titration Stability | ±1 mV / 3 h |
| Burette Resolution | 10 mL burette: 1/20000 |
| 20 mL burette | 1/10000 |
| Burette Accuracy | 10 mL: ±0.05 mL |
| 20 mL | ±0.07 mL |
| Titration Repeatability | 0.3% |
| Power Supply | AC (220 ± 22) V, (50 ± 1) Hz |
| Dimensions (W×D×H) | 340 × 400 × 400 mm |
| Weight | 10 kg |
| [Brand | LeiCi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZDJ-4A |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | (0.00–14.00) pH |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | 0.01 pH |
| Titration Accuracy | (±0.3 mV ±1 digit) / 3 h |
| Titration Resolution | 10 mL burette: 1/20,000 |
| 20 mL burette | 1/10,000 |
| Burette Error | 10 mL: ±0.025 mL |
| 20 mL | ±0.035 mL |
| Temperature Compensation Range | (−5.0–105.0) °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.3 °C |
| Power Supply | AC (220 ± 22) V, (50 ± 1) Hz |
| Dimensions (W×D×H) | 340 × 400 × 400 mm |
| Weight | 10 kg] |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | ZDJ-4A |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | pH: 0.00–14.00 |
| mV | −1800.0–+1800.0 mV |
| Temperature | −5.0–105.0 °C |
| Meter Accuracy | ±0.01 pH / ±0.03% FS (mV) |
| Meter Resolution | pH: 0.01 pH |
| mV | 0.1 mV |
| Temperature | 0.1 °C |
| Stability | (±0.3 mV ±1 digit)/3 h |
| Titration Repeatability | 0.2% |
| Burette Accuracy | ±0.025 mL (10 mL burette), ±0.035 mL (20 mL burette) |
| Burette Resolution | 1/10000 (10 mL), 2/10000 (20 mL) |
| Burette Fill/Dispense Time | (55 ± 10) s (at full scale) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 340 × 400 × 400 mm |
| Weight | 10 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | ZDJ-4B |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | (0.00–14.00) pH |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | 0.01 pH |
| Titration Accuracy | ±0.3 mV ±1 digit over 3 h |
| Titration Resolution | 1/20,000 for 10 mL burette |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ZDJ-4B |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | (0.00–14.00) pH |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | 0.01 pH |
| Titration Stability | (±0.3 mV ±1 digit)/3 h |
| Titration Resolution | 10 mL burette: 1/20000 |
| 20 mL burette | 1/10000 |
| Burette Accuracy | 10 mL: ±0.025 mL |
| 20 mL | ±0.035 mL |
| Temperature Compensation Range | (−5.0–105.0) °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.3 °C |
| Power Supply | AC (220 ± 22) V, (50 ± 1) Hz |
| Dimensions (W×D×H) | 340 × 400 × 400 mm |
| Weight | 10 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ZDJ-5 Coulometric Titrator |
| Price Range | USD 700 – 7,000 |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | (−1999.9 to +1999.9) mV |
| Meter Accuracy | ≤0.5% of full scale (minimum integration time: 3 s) |
| Electrolysis Current Settings | 1 mA, 10 mA, 50 mA |
| Electrolysis Current Accuracy | ±0.25% of reading (max. load: 500 Ω) |
| Repeatability in Titration | ≤0.5% (min. integration time: 3 s) |
| Power Supply | AC (220 ± 22) V, (50 ± 1) Hz |
| Dimensions (L×W×H) | 360 × 300 × 300 mm |
| Weight | 10 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ZDJ-520 |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | pH (0.00–14.00) |
| Electronic Unit Display | pH (−2.00–20.00), mV (0.0–±1999.9), Temperature (−5.0–105.0)°C |
| Electrode Unit Accuracy | ≤1.0% |
| Electrode Unit Resolution | 0.01 pH, 0.1 mV, 0.1°C |
| Repeatability (Burette Delivery) | ≤1.0% |
| pH Accuracy | ±0.01 pH ±1 digit |
| mV Accuracy | ±0.03% FS |
| Temperature Accuracy | ±0.3°C |
| Power Supply | AC (220 ± 22) V, (50 ± 1) Hz |
| Dimensions (W × D × H) | 600 × 455 × 720 mm |
| Weight | 50 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | ZDJ-5B |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | (−2000.00 to +2000.00) mV |
| Meter Accuracy | ±0.03% or ±0.2 mV (mV mode) |
| Meter Resolution | 0.01 mV |
| Titration Accuracy | 0.0003 mL |
| Titration Resolution | 1/30,000 |