Automatic Potentiometric Titrator
Filter
Showing 31–60 of 226 results
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZDJ-600 |
| Measurement Range | ±2400 mV / ±20 pH |
| Meter Accuracy | 0.01 mV / 0.001 pH |
| Meter Resolution | 0.01 mV / 0.001 pH |
| Titration Accuracy | ±10 µL (at 10 mL) |
| Titration Resolution | 1/20000 |
| Overall Accuracy | ±0.1% |
| Precision | ≤0.1% |
| Input Impedance | ≥3×10¹² Ω |
| Input Current | ≤1×10⁻¹² A |
| Temperature Range | 0–125 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Humidity Range | 10–85% RH |
| Humidity Resolution | 1% RH |
| Humidity Accuracy | ±5% RH |
| Titration Speed | 1–99 mL/min (adjustable) |
| Titration Tube Mounting | Tool-free replacement |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GT-100 |
| Pricing | Upon Request |
| Brand | HACH |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | AUT-701 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| pH Measurement Range | 0–14 |
| Burette Reading Accuracy | ±0.01 mL |
| Burette Resolution | 0.00005 mL |
| Titration Precision | ±0.1% |
| Simultaneous Titration Channels | 2 |
| Electrode Inputs | Up to 4 (pH/mV standard |
| Maximum Burettes Supported | 10 |
| Data Storage Capacity | 100 methods per system (expandable to 200) |
| Connectivity | USB (hot-swappable), LAN (standard), RS-232 (optional) |
| Validation Support | Built-in electrode calibration logging, burette volume verification, optional temperature/humidity environmental monitoring |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Titralab 1000 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Dedicated Use |
| pH Measurement Range | 0–14 |
| Burette Resolution | 1/20,000 |
| Titrant Dispensing Precision | ±0.001 mL |
| Display Resolution (pH/mV) | 0.001 pH / 0.1 mV |
| Temperature Range | –10 to +100 °C (0.1 °C resolution) |
| Compliance | GLP, FDA 21 CFR Part 11, ISO/IEC 17025-aligned operation |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | AT1000 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Titration Modes | Potentiometric (zero-current or controlled-current), Amperometric, Colorimetric |
| Measured Parameters | mV/pH, Conductivity, Temperature |
| Resolution | ±0.1 mV / ±0.001 pH |
| Conductivity | ±0.5% of reading |
| Temperature | ±0.3°C |
| Sample Holder | Integrated magnetic stirrer, max. 250 mL beaker |
| Electrode Inputs | Dual-channel, supports IntelliCAL digital electrodes (plug-and-play), analog electrodes, and colorimetric sensors |
| Burette Capacity Options | 2.5 / 5 / 10 / 25 mL (ISO 8655-3 compliant) |
| Stepper Motor Resolution | 20,000 steps with microstepping (128 µsteps/step) |
| Calibration Modes | Electrode and titrant calibration (auto, fixed, custom |
| Calibration Reminders | User-definable intervals |
| Data Storage | Last 100 measurements (samples, blanks, QC standards) + last 10 calibrations, including timestamp, operator ID, sample ID |
| Data Export | USB drive, CSV format |
| Interface | Silicone keypad |
| Display | 5.7" color VGA touchscreen |
| Calibration Curve Display | Direct or derivative plots, electrode response curves |
| Software & Accessories | PC software (TitraWin), analytical balance interface, autosampler, barcode scanner, peristaltic pump, paddle stirrer |
| Maintenance Scheduler | Configurable user-defined schedule |
| Predefined Functions | Bubble purge, reagent pre-fill, replaceable burette and pump modules |
| Password Protection | Enabled, customizable |
| Languages | English, French, German, Italian, Spanish |
| Connectivity | 2× electrode ports, 2× USB, 1× RS-232, 1× Ethernet |
| Dimensions (H×W×D) | 220 × 400 × 360 mm |
| Weight | 4 kg |
| Power | 100–240 VAC, 50/60 Hz |
| Operating Environment | 15–35°C, 20–80% RH (non-condensing) |
| Storage Range | −5–40°C |
| Safety & EMC Compliance | IEC/EN 61010-1, IEC/EN 61326-1 |
| Application Library | Preloaded methods for water/wastewater (alkalinity, hardness, chlorine, FOS/TAC), food & beverage (total acidity, SO₂, salt), petrochemical (TAN, TBN, bromine number), environmental (AUTOCAT), and Karl Fischer moisture (KF1121 variant) |
| Brand | Hanna Instruments |
|---|---|
| Model | HI932 |
| Instrument Type | Universal Potentiometric Titrator |
| pH Range | –2.000 to 20.000 (selectable resolution: 0.001 / 0.01 / 0.1 pH) |
| mV Range | –2000.0 to 2000.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1 mV (@25°C) |
| ISE Range | 1×10⁻⁶ to 9.99×10¹⁰ |
| ISE Accuracy | ±0.5% (monovalent), ±1% (divalent) |
| Temperature Range | –5.0 to 105.0 °C |
| Temperature Accuracy | ±0.1 °C (@25°C, excluding probe error) |
| Burette Resolution | 1/40000 |
| Dispensing Accuracy | ±0.1% of full burette volume |
| Display | 5.7″ color LCD (320 × 240 px) |
| GLP Compliance | Full audit trail, timestamped method & result storage, user access control |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T860 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | mV: −2000.0 to +2000.0 mV |
| pH | −20.000 to +20.000 pH |
| Temperature | −5 to 120 °C |
| Meter Accuracy | ±0.1 mV, ±0.003 pH, ±0.1 °C |
| High-Resolution Mode (Optional) | 0.05 mV, 0.0001 pH |
| Meter Resolution | 0.1 mV, 0.001 pH, 0.1 °C |
| Titration Accuracy | ±0.2% |
| Titration Resolution | 1/48,000 |
| Burette Options | Standard 10 mL |
| Burette Refill Time | 16 s (at 100% fill rate) |
| Stirring Method | Magnetic stirring |
| Electrode Interfaces | mV/pH input, reference electrode input, PT1000 temperature probe input |
| Communication Ports | 2× USB, RS232, power interface |
| Data Storage | 4 GB internal flash memory with multi-level search capability |
| User Management | Four-tier permission system with customizable access rights, electronic signature support, audit-trail-enabled data integrity controls, password policy enforcement (complexity, aging, expiration) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T860 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | ±1,999 mV / 0.00–14.00 pH |
| Potentiometric Accuracy | ±0.2 mV / ±0.02 pH |
| Resolution | 0.1 mV / 0.01 pH |
| Titration Repeatability | ≤0.2% |
| Temperature Measurement Range | 0–100 °C (PT1000) |
| Resolution | 0.1 °C |
| Max Error | ±0.2 °C |
| Burette Capacities | 15 mL (±0.025 mL tolerance), 25 mL (±0.035 mL tolerance) |
| Display | 7-inch color TFT touchscreen |
| Power Supply | 110–240 V AC, 50/60 Hz |
| Weight | 10 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T910 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose |
| Measurement Range | 0–300 mg KOH/100 g dry matter |
| mV Range | −2000.0 to +2000.0 mV |
| pH Range | −20.000 to +20.000 pH |
| Electrode Readout Accuracy | RSD ≤ 0.3% |
| Resolution | 0.01 mg KOH/100 g dry matter |
| Titration Resolution | 1/1,500,000 |
| Temperature Range | −5 to 120 °C |
| Temp. Accuracy | ±0.1 °C |
| Titration Tube Options | 1 mL / 5 mL / 10 mL / 25 mL |
| Refill Time (100% fill) | 16 s |
| Communication Interfaces | Dual USB, RS-232, Ethernet, CAN bus |
| Electrode Ports | mV/pH input, reference electrode port, PT1000 temperature probe port |
| Audit Trail | FDA 21 CFR Part 11 compliant |
| Electronic Signature | Supported |
| Data Integrity | Immutable export with checksum verification |
| User Management | Role-based, multi-level permissions |
| Sample Handling | Standalone station or optional auto-samplers (16×100 mL, 12×250 mL, 18×50 mL) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T960 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose |
| mV Measurement Range | −2000.0 mV to +2000.0 mV |
| mV Resolution & Accuracy | 0.1 mV resolution, ±0.1 mV ± 0.03% accuracy |
| pH Measurement Range | −20.000 to +20.000 pH |
| pH Resolution & Accuracy | 0.001 pH resolution, ±0.003 pH accuracy |
| Temperature Measurement Range | −5 °C to 120 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Burette Resolution | 1/1,500,000 |
| Burette Volume Options | 1 mL / 5 mL / 10 mL / 25 mL |
| Auxiliary Reagent Channels | Up to 4+4 (8-channel synchronized dosing) |
| Electrode Interfaces | mV/pH, reference, PT1000 temperature, optional polarographic |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T960 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose |
| mV Measurement Range | −2000.0 to +2000.0 mV |
| mV Resolution & Accuracy | 0.1 mV |
| pH Measurement Range | −20.000 to +20.000 pH |
| pH Resolution | 0.001 pH |
| pH Accuracy | ±0.003 pH |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±0.1 °C |
| Titration Tube Options | 5 mL / 10 mL / 25 mL |
| Maximum Simultaneous Dosing Channels | 4 (expandable to 6) |
| Titration Tube Resolution | 1/48,000 steps |
| Refill Time (100% fill) | 16 s |
| Electrode Interfaces | pH/mV input, reference electrode port, PT1000 temperature probe port |
| Communication Interfaces | Dual USB, RS-232, Ethernet |
| Cloud Connectivity | Yes (secure, role-based, audit-ready) |
| Brand | Hiranuma |
|---|---|
| Origin | Japan |
| Model | COM-28/28S |
| Measurement Range | −200 mV to +2000 mV |
| Potential Resolution | 0.1 mV |
| Display | 4.3-inch TFT LCD touchscreen (Chinese UI) |
| Data Storage | 50 internal records + up to ~9,900 via USB flash drive |
| Dimensions | 255 mm (W) × 290 mm (D) × 420 mm (H) |
| Optional accessories | C-1712 autosampler (12-position), photometric titration unit, dual external burettes |
| Brand | Hiranuma |
|---|---|
| Origin | Japan |
| Model | COM-A19 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Measurement Range | −2000 to +2000 mV |
| Display Resolution | 0.1 mV |
| Touchscreen | 8.4-inch Color LCD with 16-step Adjustable Viewing Angle |
| Stirrer Speed Control | 40-step Adjustable |
| Stirring Mode | Continuous Forward/Reverse Rotation |
| Status Indication | Dual-color LED Operational Indicator & Tri-color LED System Status Light |
| Data Interface | USB Port + LAN (Web-based Remote Access) |
| Built-in Thermal Printer | 58 mm Paper Width |
| Titration Head Design | Plug-and-Play Reagent Cartridge System |
| Audio Feedback | Voice Prompt Function |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HOGON Scientific Instruments Co., Ltd. |
| Model | ALT-1 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | Dedicated Industrial Process Monitoring |
| pH Range | 0–20 |
| mV Range | −2000 to +2000 mV |
| pH Resolution | 0.001 |
| mV Resolution | 0.1 mV |
| Absorbance Resolution | 0.003 Abs |
| Titration Precision | ±1 µL (using 20 mL burette) |
| Analysis Interval | 15–999 minutes adjustable |
| Output Signals | 4–20 mA, Modbus TCP, CAN |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ALT-1 Online Automatic Potentiometric Titrator |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | pH: 0–20 |
| mV | −2000 to +2000 |
| Resolution | 0.001 pH / 0.1 mV / 0.003 Abs |
| Titration Accuracy | ±1 µL (using 20 mL burette) |
| Analysis Interval | 15–999 minutes adjustable |
| Output Signals | 4–20 mA / Modbus TCP / CAN |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AT-1 Advanced |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | mV: −2000 to +2000 mV |
| pH | 0.000–14.000 |
| Temperature | −55 to +125 °C |
| Meter Accuracy | ±0.5% of full scale |
| Meter Resolution | 0.1 mV |
| Titration Precision | 0.8 mV/h |
| Input Impedance | >1 × 10¹² Ω |
| Bias Current | <1 × 10⁻¹² A |
| Titration Volume Resolution | 1 µL (with 20 mL burette) |
| Electrode Interfaces | Composite, Reference, Indicator, and Temperature Electrode Ports |
| GLP Compliance | User authentication, audit trail, electrode & titrant logging, PDF report export, method versioning |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | AT-1 Advanced |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | mV: −2000 to +2000 mV |
| pH | 0.000–14.000 |
| Temperature | −55.0 to +125.0 °C |
| Meter Accuracy | ±0.5% of full scale |
| Meter Resolution | 0.1 mV |
| Titration Accuracy | ±0.8 mV/h |
| Titration Resolution | 0.1 mV |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Model | AT-1 (Single pH/Conductivity Module) |
| Measurement Range | −2000 mV to +2000 mV |
| Meter Accuracy | ±0.5% of full scale |
| Meter Resolution | 0.1 mV |
| Titration Accuracy | 0.8 mV/h |
| Titration Resolution | 0.1 mV |
| Compatible Buret Volumes | 10 mL, 20 mL |
| Minimum Dispensed Volume | 3 µL |
| Electrode Interfaces | Multi-port universal electrode connector (pH, reference, indicator, temperature) |
| Temperature Compensation | Integrated Pt1000 thermistor with automatic pH compensation |
| Data Export Format | PDF, CSV |
| Compliance | GLP-compliant audit trail, user authentication & role-based access control |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | AT-1 |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | mV: −2000 mV to +2000 mV |
| Meter Accuracy | ±0.5% of full scale |
| Meter Resolution | 0.1 mV |
| Titration Accuracy | ±0.8 mV/h |
| Titration Resolution | 0.1 mV |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AT-6 Karl Fischer Module |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | −2000 mV to +2000 mV |
| Meter Accuracy | ±0.35% of full scale |
| Meter Resolution | 0.1 mV |
| Titration Precision | ±0.01 pH over 3 h |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | CT-1PLUS Advanced |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Ranges | Potential: ±2000 mV |
| pH | 0–14 pH |
| Temperature | −5 to 125 °C |
| Meter Accuracy | ±0.3% of full scale |
| Meter Resolution | Potential: 0.1 mV |
| pH | 0.001 pH |
| Temperature | 0.1 °C |
| Titration Accuracy | (±0.3 mV ±1 digit) over 3 h |
| Titration Resolution | ±2000 mV range, 0.1 mV resolution, ±0.2 mV absolute accuracy |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Universal Automatic Potentiometric Titrator |
| Application Scope | General-purpose with HF-optimized colorimetric endpoint detection |
| pH Measurement Range | 1–14 |
| Potentiometer Display Accuracy | ±0.2 mV |
| Potentiometer Resolution | 0.1 mV (range: ±2000 mV) |
| Titration Precision | 0.001 mL (standard 20 mL burette) |
| Titration Resolution | 0.0005 mL (optional 10 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | General-Purpose Automatic Potentiometric Titrator |
| Model | CT-1Plus (Color-Endpoint Detection Enabled) |
| Measuring Range | Potential: ±1024 mV |
| pH | 0–14 pH |
| Meter Accuracy | ±0.5% of full scale |
| Meter Resolution | 0.1 mV (potential), 0.001 pH |
| Titration Accuracy | (±0.3 mV ±1 digit) over 3 h |
| Titration Range | ±2000 mV |
| Resolution | 0.1 mV |
| Absolute Accuracy | ±0.2 mV |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | CT-1Plus |
| Instrument Type | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| pH Measurement Range | 1–14 |
| Meter Display Accuracy | ±0.1 mV |
| Meter Resolution & Range | ±2000 mV, 0.1 mV resolution |
| Titration Accuracy | 0.001 mL (20 mL burette, standard) |
| Titration Resolution | 0.0005 mL (10 mL burette, optional) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HOGON Scientific Instrument Co., Ltd. |
| Type | General-purpose automatic potentiometric titrator |
| Application Scope | Universal |
| pH Measurement Range | 1–14 |
| Potential Resolution | 0.1 mV |
| Potential Display Range | ±2000 mV |
| Potential Accuracy | ±0.2 mV |
| Burette Precision (standard 20 mL) | 0.001 mL |
| Burette Resolution (optional 10 mL) | 0.0005 mL |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HOGON Scientific Instruments Co., Ltd. |
| Model | CT-1P |
| Instrument Type | General-purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | Potential: ±2000 mV |
| pH | 0–14 |
| Temperature | −5 to 125 °C |
| Meter Accuracy | ±0.3% of full scale |
| Meter Resolution | Potential: 0.1 mV |
| pH | 0.001 |
| Temperature | 0.1 °C |
| Titration Accuracy | (±0.3 mV ±1 digit) over 3 h |
| Titration Resolution | ±2000 mV range, 0.1 mV resolution, ±0.2 mV absolute accuracy |
| Minimum Dispensing Volume | 10 µL |
| Maximum Dispensing Volume | 100 µL |
| Stirring Speed | 200 rpm |
| Drop Interval | 1000 ms |
| Endpoint Detection Mode | First Derivative (dE/dV), Threshold Set at 200 mV/mL |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose, optimized for cathode material residual alkali quantification |
| pH Measurement Range | 1–14 |
| Potentiometer Accuracy | ±0.2 mV |
| Potentiometer Resolution | 0.1 mV (within ±2000 mV range) |
| Burette Precision | 0.001 mL (standard 20 mL burette) |
| Burette Resolution | 0.0005 mL (optional 10 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CT-1Plus |
| Instrument Type | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| pH Measurement Range | 1–14 |
| Potential Meter Accuracy | ±0.2 mV |
| Potential Meter Resolution | 0.1 mV (Range: ±2000 mV) |
| Titration Precision | 0.001 mL (20 mL burette, standard) |
| Titration Resolution | 0.0005 mL (10 mL burette, optional) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | CT-1Plus |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | General-purpose |
| Measurement Range | Potential: ±2000 mV |
| pH | 0–14 |
| Temperature | −5 to 125 °C |
| Meter Accuracy | ±0.3% of full scale |
| Meter Resolution | 0.1 mV (potential), 0.001 pH unit, 0.1 °C |
| Titration Accuracy | (±0.3 mV ±1 digit) over 3 h |
| Titration Resolution | ±2000 mV range, 0.1 mV resolution, ±0.2 mV absolute accuracy |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CT-1Plus Automatic Potentiometric Titrator for Chloride Ion Determination in Compound Fertilizers |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| pH Measurement Range | 1–14 |
| Meter Display Accuracy | ±0.1 mV |
| Meter Resolution & Range | ±2000 mV, 0.1 mV resolution |
| Titration Accuracy | 0.001 mL (20 mL burette, standard) |
| Titration Resolution | 0.0005 mL (10 mL burette, optional) |