Empowering Scientific Discovery

Azure China

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAzure Biosystems
OriginUSA
ModelAzure 300
Instrument TypeChemiluminescent Gel Imaging System
CCD Resolution9.1 MP
Bit Depth16-bit
Dynamic Range4.8 OD
CCD Sensor Size2/3-inch
Detection Sensitivitysub-femtogram (fg) level
Signal-to-Noise RatioHigh
LensFixed-focus, large-aperture optics
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAzure Biosystems
OriginUSA
ModelSapphire RGBNIR
Instrument TypeMulticolor Fluorescent Gel Imaging System
CCD Resolution6.1 MP
Bit Depth16-bit
Dynamic Range≥6 OD
CCD Sensor SizeLarge-format CCD
Detection Sensitivityfg-level
Signal-to-Noise RatioHigh SNR
Optical LensMotorized Autofocus
Excitation SourcesFour Solid-State Lasers (RGB + NIR)
Detector ArchitectureIntegrated PMT, APD, and CCD Detection Modalities
Imaging ModesRGB Fluorescence, NIR Fluorescence, Chemiluminescence, Visible Light, Phosphor Imaging (with optional PI module), Autoradiography
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAzure Biosystems
OriginUSA
ModelCielo 6 / Cielo 3
Instrument TypeReal-Time Fluorescent Quantitative PCR System
Sample Throughput96-well format
Max Heating Rate6°C/s
Temperature Accuracy±0.1°C
Well-to-Well Temperature Uniformity±0.2°C
Excitation SourceHigh-Power LED (450–730 nm for Cielo 6
Detection Channels6 (Cielo 6) / 3 (Cielo 3)
Multiplexing CapacityUp to 6 targets (Cielo 6) / up to 3 targets (Cielo 3)
Reaction Volume1–150 µL (10–65 µL recommended)
Dynamic Range10 logs
Onboard Memory32 GB (~20,000 experiments)
ConnectivityUSB, Wi-Fi, Ethernet
Footprint30.5 × 50.8 × 43.2 cm (W × D × H)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAzure Biosystems
OriginUSA
ModelchemiSOLO
Instrument TypeChemiluminescence Gel Imager
Camera Sensor6.3 MP cooled back-illuminated CMOS
Bit Depth24-bit
Dynamic Range7.2 OD (EDR mode)
Sensor Size2-inch format
Detection Sensitivitysub-femtogram (fg) level
Signal-to-Noise RatioHigh SNR
Lens SystemMotorized autofocus
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAzure Biosystems
OriginUSA
ModelAzure 200
Instrument TypeStandard Gel Imaging System
CCD Resolution5.4 MP
Bit Depth16-bit
Dynamic Range4.8 OD
CCD Sensor Size2/3-inch
Detection Sensitivityfg-level
Signal-to-Noise RatioHigh
LensMotorized Autofocus
Integrated Display13.3-inch HD Touchscreen PC
Excitation SourcesDual-wavelength UV (e.g., 254 nm & 302 nm), Blue Light (470 nm)
Imaging ModesDNA, Protein, Colorimetric, Fluorescent (with compatible dyes)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAzure Biosystems
OriginUSA
ModelAzure 400
Instrument TypeMulticolor Fluorescence Gel Imaging System
CCD Resolution9.1 MP
Bit Depth16-bit
Dynamic Range4.8 OD
CCD Sensor Size2/3-inch
Detection Sensitivityfg-level
Signal-to-Noise RatioHigh
LensFixed-focus, Large-aperture Optical Lens
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAzure Biosystems
OriginUSA
ModelAzure 500
Instrument TypeMultispectral Fluorescence Gel Imaging System
CCD Resolution9.1 MP
Bit Depth16-bit
Dynamic Range4.8 OD
CCD Sensor Size2/3"
Detection Sensitivityfg-level
Signal-to-Noise RatioHigh
Lens SystemMotorized Autofocus
Integrated Display13.3" HD Touchscreen PC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAzure Biosystems
OriginUSA
ModelAzure 600
Instrument TypeMulticolor Fluorescence Gel Imaging System
CCD Resolution9.1 MP
Bit Depth16-bit
Dynamic Range4.8 OD
CCD Sensor Size2/3-inch
Detection Sensitivityfg-level
Signal-to-Noise RatioHigh
Lens SystemMotorized Autofocus
Integrated Display13.3-inch HD Touchscreen PC
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0