Balance/Scale
Filter
Showing 61–90 of 442 results
| Brand | Adam Equipment |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CARRY CASE |
| Instrument Category | Accessory for Portable Balances |
| Compatible Models | ACBplus, AQT Series Portable Balances |
| Brand | Adam Equipment |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | CKT |
| Price Range | USD 1–4,999 |
| Brand | Adam Equipment |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Direct Manufacturer |
| Import Status | Imported |
| Model | GBK/GFK |
| Price Range | USD 495–820 (FOB) |
| Capacity Options | 150 kg, 300 kg, 600 kg |
| Readability | 50 g (150 kg), 100 g (300 kg), 200 g (600 kg) |
| Display | Backlit LCD, 40 mm high digits |
| Keypad | Sealed membrane keypad |
| Overload Indication | Built-in range-tracking bar + tri-color backlight (green/amber/red) |
| Weighing Units | g, kg, lb, lb:oz, oz |
| Counting Resolution | 1:1,000,000 internal |
| Piece Counting | Auto-average part weight calculation, preset sample count mode |
| Data Interface | RS-232 standard |
| Power Supply | AC adapter (12 VDC, 800 mA) + rechargeable internal battery (up to 120 h operation) |
| Calibration | External calibration required |
| Construction | Powder-coated steel base frame, ABS plastic indicator housing |
| Operating Temperature | −10 °C to +40 °C |
| IP Rating | IP65-rated indicator (dust-tight, water-jet resistant) |
| Compliance | CE, UKCA, OIML R76-1 (Class III), ISO 9001 certified manufacturing |
| Brand | Adam Equipment |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model Series | GGS / GGB / GGF / GGL |
| Price Range | USD 850 – 1,700 (FOB UK) |
| IP Rating | IP67 |
| Construction | 304 Stainless Steel Platform & Housing |
| Power | Rechargeable Li-ion Battery (120 h typical runtime) + AC Adapter |
| Display | Backlit LCD, 40 mm digit height |
| Connectivity | RS-232 serial interface |
| Calibration | External calibration required |
| Operating Temperature | −10 °C to +40 °C |
| Weighing Units | g, kg, lb, lb:oz, oz, N, user-defined units |
| Special Functions | Animal/dynamic weighing with adjustable digital filtering, parts counting, preset tare, hold/lock function |
| Brand | Adam Equipment |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HCB 602H |
| Instrument Type | Precision Balance |
| Capacity | 600 g |
| Readability | 0.01 g |
| Repeatability (s.d.) | 0.002 g |
| Linearity Error | ±0.02 g |
| Pan Size | 120 mm diameter |
| Calibration Method | Internal HandiCal™ Auto-Calibration |
| Stabilization Time | ≤2 s |
| Operating Temperature Range | 0–40 °C |
| Power Supply | 12 V DC, 800 mA (AC adapter included) |
| Display | 6-digit backlit LCD with capacity tracking bar |
| Connectivity | Dual RS-232 and USB interfaces |
| Construction | ABS plastic housing with stainless steel weighing pan |
| Dimensions (W×D×H) | 170 × 245 × 80 mm |
| Net Weight | 1.5 kg |
| Compliance | ISO/IEC 17025 compatible operation |
| Brand | Adam Equipment |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HCB1002 |
| Maximum Capacity | 1000 g |
| Readability | 0.01 g |
| Repeatability | 0.02 g |
| Calibration | Automatic Internal Calibration (HandiCal™) |
| Power Supply | Rechargeable Li-ion Battery & AC Adapter (12 VDC, 800 mA) |
| Interface | RS-232 and USB Bidirectional |
| Stabilization Time | ≤2 s |
| Operating Temperature | 0–40 °C |
| Display | 6-digit LCD with auto-backlight and capacity tracking bar |
| Pan Size | 120 mm Ø stainless steel |
| Dimensions (W×D×H) | 170 × 245 × 80 mm |
| Net Weight | 1.5 kg |
| Compliance | CE, UKCA, ISO/IEC 17025 traceable calibration support |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | LBX |
| Price Range | USD 1 – 4,999 |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | LPB |
| Instrument Type | Precision Balance |
| Capacity Range | 500–1000 g |
| Readability | 0.001 g |
| Calibration | Internal or External |
| Maximum Capacity | 820 g |
| Measurement Accuracy | 0.001 g |
| Repeatability | 0.002 g |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | LTB |
| Instrument Type | Precision Balance |
| Capacity Range | 2000–5000 g |
| Maximum Capacity | 6000 g |
| Readability | 0.01 g |
| Calibration | Internal or External |
| Repeatability | 0.02 g |
| Linearity Error (±) | 0.03 g |
| Minimum Weight | 20 g |
| Stabilization Time | 2 s |
| Display | Backlit LCD with 24 mm high white digits on black background |
| Weighing Units | g, kg, ct, GN, N, dr, lb, oz, lb:oz, ozt, dwt, tl.T, tl.H, tl.S, T, Custom |
| Interface | RS-232, USB |
| Operating Temperature | 15–35 °C |
| Power Supply | 18 V DC, 50/60 Hz, 830 mA adapter |
| Housing Material | ABS plastic |
| Pan Material | 304 stainless steel |
| Pan Size | 185 × 185 mm |
| Dimensions (W × D × H) | 224 × 374 × 95 mm |
| Net Weight (Internal Calibration Models) | 5.9 kg |
| Net Weight (External Calibration Models) | 4.5 kg |
| Functions | Weighing, Piece Counting, Percentage Weighing, Checkweighing, Check Counting, Animal/Dynamic Weighing, Density Determination, Net/Gross Weighing, Display Hold, Peak Hold |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Adam Equipment Ltd. |
| Product Type | Imported Precision Balance |
| Model | LBB |
| Instrument Category | Precision Balance |
| Maximum Capacity | 15,000 g |
| Readability | 0.1 g |
| Calibration Method | External Calibration |
| Repeatability | 0.2 g |
| Linearity Error (±) | 0.3 g |
| Minimum Weight | 200 g |
| Stabilization Time | 2 s |
| Weighing Units | g, kg, ct, GN, N, dr, lb, oz, lb:oz, ozt, dwt, tl.T, tl.H, tl.S, T, Custom Units |
| Interfaces | RS-232, USB |
| Operating Temperature | 15–35 °C |
| Power Supply | 18 V DC, 50/60 Hz, 830 mA adapter |
| Display | Backlit LCD with 24 mm high white digits on black background |
| Housing Material | ABS plastic |
| Pan Material | 304 stainless steel |
| Pan Size | 185 × 185 mm |
| Dimensions (W × D × H) | 224 × 374 × 95 mm |
| Net Weight | 4.5 kg |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Adam Equipment (UK) |
| Product Type | Analytical Balance |
| Model | LAB Series (e.g., LAB 214i, LAB 254e) |
| Maximum Capacity | 250 g |
| Readability | 0.0001 g |
| Repeatability | ±0.0002 g |
| Linearity Error | ±0.0003 g |
| Minimum Weight | 200 mg |
| Stabilization Time | 2 s |
| Calibration | Internal (i-models) or External (e-models) |
| Display | Backlit LCD, 24 mm digit height |
| Weighing Units | g, mg, ct, GN, N, dr, oz, ozt, dwt, mm, tl.T, tl.H, tl.S, T, user-defined |
| Interfaces | RS-232, USB |
| Operating Temperature | 15–35 °C |
| Power Supply | 18 V DC, 50/60 Hz, 830 mA adapter |
| Housing Material | ABS plastic |
| Pan Material | 304 stainless steel |
| Pan Size | 90 mm diameter |
| Draft Shield | Standard tempered glass square shield (192 × 195 × 230 mm W×D×H) |
| Dimensions (W×D×H) | 224 × 374 × 338 mm |
| Net Weight | 6.2 kg (i-models), 5.8 kg (e-models) |
| Compliance | GLP-compliant data logging, ISO/IEC 17025 support, USP Chapter 41 & 1251 compatible |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MUW |
| Price Range | USD 1,400 – 4,200 |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DDK |
| Instrument Type | Analytical Balance-Compatible Density Kit |
| Balance Compatibility | Adam NBL Series Balances Only |
| Maximum Load Capacity (with NBL balance) | 800 g |
| Mass Readability | 0.0001 g (0.1 mg) / 0.001 g (1 mg) |
| Repeatability | ±0.0001 g / ±0.001 g |
| Calibration | Internal Automatic or Manual Calibration Supported |
| Density Measurement Range | Solid & Liquid Samples |
| Measurement Principle | Archimedean Buoyancy Method (ASTM D792, ISO 1183, USP <841>) |
| Brand | Adam |
|---|---|
| Origin | UK |
| Manufacturer | Adam Equipment |
| Model | NBL / NBL-p |
| Capacity | 2000–5000 g (up to 32,000 g) |
| Readability | 0.1 g |
| Internal Resolution | 0.00001 g (10 µg) |
| Repeatability | ±0.2 g |
| Linearity Error | ±0.4 g |
| Operating Temperature | 0–40 °C |
| Power Supply | 12 V DC, 50/60 Hz, 800 mA |
| Display | Backlit LCD (digit height 20 mm) |
| Weighing Pan | 304 Stainless Steel (400 × 300 mm) |
| Dimensions (W×D×H) | 401 × 460 × 102 mm (base), column: 401 × 500 × 600 mm |
| Net Weight | 4.5–7.3 kg |
| Communication | USB + bidirectional RS-232 |
| Weighing Modes | Standard, Net/Gross, Checkweighing, Percentage, Piece Counting, Animal/Dynamic, Density, Below-Balance |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SAB |
| Instrument Type | Analytical Balance |
| Capacity Range | 200–500 g |
| Readability | 0.01 mg (10 µg) / 0.1 mg (100 µg) |
| Calibration | Internal Automatic Calibration & External Calibration |
| Maximum Capacity | 510 g |
| Repeatability | 0.02 mg |
| Display | 15 mm high graphic LCD |
| Interface | RS-232 |
| Operating Temperature | 10–30 °C |
| Power Supply | 24 V DC, 50/60 Hz, 500 mA adapter |
| Net Weight | 6.7–7.0 kg |
| Dimensions (W×D×H) | 224 × 374 × 338 mm |
| Pan Size | 80 mm diameter |
| Draft Shield | Standard glass square draft shield (192 × 195 × 230 mm) |
| Housing Material | ABS plastic |
| Compliance | GLP-compliant data logging, password protection, audit-ready timestamped output |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SPB363i / SPB723i / SPB1203i / SPB2103i (Internal Calibration) / SPB363e / SPB723e (External Calibration) |
| Weighing Capacity | 360 g – 2100 g |
| Readability | 0.001 g |
| Repeatability | ±0.002 g |
| Linearity Error | ±0.003 g to ±0.005 g |
| Stabilization Time | ≤3 s |
| Calibration | Internal (i-series) or External (e-series) |
| Display | 15-mm-high graphical LCD |
| Pan Size | 110 mm diameter |
| Draft Shield | Standard tempered glass square shield (192 × 195 × 115 mm, W×D×H) |
| Housing Material | ABS plastic |
| Dimensions (W×D×H) | 224 × 374 × 219 mm |
| Net Weight | 6.4 kg (i-series), 6.7 kg (e-series) |
| Power Supply | 24 V DC, 50/60 Hz, 500 mA adapter |
| Operating Temperature | 10 °C – 30 °C |
| Connectivity | RS-232 |
| Weighing Units | g, mg, ct, GN, lb, oz, ozt, dwt, mm, tl.T, tl.H, tl.S, T, user-defined |
| Compliance | GLP-compliant data logging (date/time stamp), password protection, audit-ready operation |
| Brand | Adam |
|---|---|
| Origin | UK |
| Manufacturer | Adam Equipment |
| Type | Precision Balance |
| Model | STB |
| Capacity | 3200–8200 g |
| Readability | 0.01 g |
| Repeatability | ±0.02 g |
| Linearity Error | ±0.03–0.04 g |
| Stabilization Time | 3 s |
| Calibration | Internal (i-models) or External (e-models) |
| Display | 15 mm high graphical LCD |
| Weighing Units | g, mg, ct, GN, lb, oz, ozt, dwt, mm, tl.T, tl.H, tl.S, T, custom |
| Interface | RS-232 |
| Operating Temperature | 10–30 °C |
| Power Supply | 24 V DC, 50/60 Hz, 500 mA adapter |
| Pan Size | 185 × 185 mm |
| Dimensions (W×D×H) | 224 × 374 × 95 mm |
| Net Weight | 6.4 kg (i), 6.7 kg (e) |
| Construction | ABS housing, 304 stainless steel pan |
| Compliance | GLP-compliant data logging, password protection, audit-ready timestamped printouts |
| Brand | AMAE |
|---|---|
| Model | AM-1260 |
| Origin | Guangdong, China |
| Instrument Type | Automated Thermogravimetric Ashing & Weighing Platform |
| Temperature Control | 20-Step Programmable Ramp/Soak Profile |
| Atmosphere Options | Air, N₂, O₂ (0–20 L/min flow control) |
| Integrated Balance | METTLER Toledo high-precision analytical balance (0.1 mg readability, high-temperature stable weighing cell) |
| Compliance Standards | GBZ/T 192.4-2007, GB 5009.3–2016, GB 5009.4–2016, GB/T 6438–2007, YC/T 427–2012 |
| Data Management | Audit-trail enabled software with CFR 21 Part 11–compatible user roles, electronic signatures, and customizable reporting |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | BM-20 |
| Type | Ultra-Micro Balance |
| Maximum Capacity | 22 g |
| Readability | 1 µg (0.001 mg) |
| Repeatability | 0.0025 mg |
| Calibration | Internal motorized calibration with built-in砝码 |
| Sample Pan | Perforated mesh design |
| Draft Shield | Conductive-coated glass with lateral sliding door |
| Interfaces | RS-232C and USB |
| Data Storage | 200 measurement records + 50 calibration logs |
| Software | WinCT-Balance (A&D certified, GLP/GMP-compliant) |
| Display | High-contrast white-backlit LCD |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | BM-22 |
| Instrument Type | Ultra-Micro Balance |
| Maximum Capacity | 22 g |
| Dual Range | 5–20 g |
| Readability | 0.1 µg (10⁻⁷ g) |
| Repeatability | 0.004 mg |
| Calibration | Internal motorized calibration with built-in砝码 |
| Communication Interfaces | RS-232C and USB |
| Data Storage | 200 measurement records + 50 calibration logs |
| Software | WinCT-Balance (GLP/GMP-compliant reporting) |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | BM-5 |
| Type | Ultra-Micro Balance |
| Capacity | 5.2 g |
| Readability | 0.001 mg (1 µg) |
| Repeatability | ±0.0012 mg |
| Calibration | Internal motorized calibration with built-in砝码 |
| Weighing Pan | Perforated mesh pan |
| Draft Shield | Conductive-coated glass with lateral sliding door |
| Interfaces | RS-232C and USB |
| Data Storage | 200 weighing records + 50 calibration logs |
| Software | WinCT (A&D proprietary GLP/GMP-compliant data acquisition and reporting suite) |
| Display | Large high-contrast white-backlit LCD |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-10001A |
| Maximum Capacity | 10200 g |
| Readability | 0.1 g |
| Calibration | External |
| Repeatability | 0.1 g |
| Instrument Type | Precision Balance |
| Capacity Range | >5000 g |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-10002A |
| Maximum Capacity | 10200 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Instrument Type | Precision Balance |
| Capacity Range | >5000 g |
| Accuracy Class | 0.01 g (100 mg) |
| Pan Size | 165 × 165 mm |
| Dimensions (W×D×H) | 212 × 317 × 93 mm |
| Stabilization Time | ≤1.0 s (at 50 g load) |
| Compliance | ISO 9001, JIS B 7721, ASTM E898 |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-1003A |
| Type | Precision Balance |
| Maximum Capacity | 1100 g |
| Readability | 0.001 g |
| Repeatability | 0.001 g |
| Calibration | External |
| Pan Size | 128 × 128 mm |
| Dimensions (W×D×H) | 212 × 317 × 171 mm |
| Stabilization Time | ~1.0 s (typical, 5 g load) |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-2002A |
| Maximum Capacity | 2200 g |
| Readability | 0.01 g |
| Repeatability | ±0.01 g |
| Calibration | External |
| Pan Size | 165 × 165 mm |
| Dimensions (W×D×H) | 212 × 317 × 93 mm |
| Compliance | ISO/IEC 17025-compatible operation, GLP/GMP-ready data logging |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-203A |
| Maximum Capacity | 220 g |
| Readability | 0.001 g |
| Repeatability | ±0.001 g |
| Calibration | External |
| Balance Type | Precision Top-Loading Balance |
| Pan Size | 128 × 128 mm |
| Dimensions (W×D×H) | 212 × 317 × 171 mm |
| Stabilization Time | ~1.0 s (typical), ~0.8 s for 5 g load |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-3002A |
| Type | Precision Balance |
| Maximum Capacity | 3200 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Weighing Pan Size | 165 × 165 mm |
| Dimensions (W×D×H) | 212 × 317 × 93 mm |
| Stabilization Time | ~1.0 s (at 50 g load) |
| Compliance | ISO 9001, JIS B 7721, ASTM E898 |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-303A |
| Type | Precision Balance |
| Maximum Capacity | 320 g |
| Readability | 0.001 g |
| Repeatability | ±0.001 g |
| Calibration | External |
| Pan Size | 128 × 128 mm |
| Stabilization Time | ~1.0 s (typical, 5 g load) |
| Dimensions (W×D×H) | 212 × 317 × 171 mm |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-4002A |
| Maximum Capacity | 4200 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Instrument Type | Precision Balance |
| Dimensions (W×D×H) | 212 × 317 × 93 mm |
| Pan Size | 165 × 165 mm |
| Stabilization Time | ≤1.0 s (at 50 g load) |
| Compliance | ISO 9001, ISO/IEC 17025 compatible workflows, GLP/GMP-ready documentation support |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-6001A |
| Maximum Capacity | 6200 g |
| Readability | 0.1 g |
| Calibration | External |
| Repeatability | 0.1 g |
| Instrument Type | Precision Balance |
| Compliance | ISO/IEC 17025-compatible operation, GLP/GMP-ready documentation support |