| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-303A |
| Type | Precision Balance |
| Maximum Capacity | 320 g |
| Readability | 0.001 g |
| Repeatability | ±0.001 g |
| Calibration | External |
| Pan Size | 128 × 128 mm |
| Stabilization Time | ~1.0 s (typical, 5 g load) |
| Dimensions (W×D×H) | 212 × 317 × 171 mm |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-4002A |
| Maximum Capacity | 4200 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Instrument Type | Precision Balance |
| Dimensions (W×D×H) | 212 × 317 × 93 mm |
| Pan Size | 165 × 165 mm |
| Stabilization Time | ≤1.0 s (at 50 g load) |
| Compliance | ISO 9001, ISO/IEC 17025 compatible workflows, GLP/GMP-ready documentation support |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-6001A |
| Maximum Capacity | 6200 g |
| Readability | 0.1 g |
| Calibration | External |
| Repeatability | 0.1 g |
| Instrument Type | Precision Balance |
| Compliance | ISO/IEC 17025-compatible operation, GLP/GMP-ready documentation support |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-6002A |
| Maximum Capacity | 6200 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Instrument Type | Precision Balance |
| Compliance | ISO/IEC 17025-ready, GLP/GMP-supportive architecture |
| Brand | AND/A&D |
|---|---|
| Origin | Japan |
| Model | GF-603A |
| Maximum Capacity | 620 g |
| Readability | 0.001 g |
| Repeatability | ±0.001 g |
| Calibration | External |
| Pan Size | 128 × 128 mm |
| Dimensions (W×D×H) | 212 × 317 × 171 mm |
| Stabilization Time | ~1.0 s (typical), ~0.8 s for 5 g load |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | SJ Series |
| Capacity Range | 1000 g to 30 kg |
| Readability | 0.5 g to 0.02 kg |
| Pan Size | 230 × 190 mm |
| Stabilization Time | <1 s |
| Power Supply | 4 × AA batteries (included) or optional AC adapter |
| Display | Large LCD, digit height 25 mm |
| Calibration | Full digital internal calibration |
| Weighing Units | g, lb, oz, lb-oz |
| Resolution Ratio | 1/2000 to 1/5000 |
| Pan Material | Stainless steel (SJ-HS models) |
| Auto Power-Off | Yes |
| Origin | Japan |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | FX-iWP |
| Price Range | USD 1–699 (est.) |
| IP Rating | IP65 |
| Stabilization Time | ≤1 s |
| Readability | 1 mg |
| Display | Large Fluorescent LCD |
| Sensor Type | SHS (Strain-Hybrid Sensor) |
| Power | AC Adapter + Rechargeable Internal Battery |
| Compliance | GLP/GMP/GCP/ISO Data Integrity Support |
| Features | Auto-counting (ACAI), Animal Weighing, Below-Balance Hook, Percent Mode, Statistics, Multiple Units, Overload Protection, Vibration Damping, Digital Calibration, Audible Alert, Tare/Zero Tracking, Auto Power Off (10 min idle) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HR250A |
| Instrument Type | Analytical Balance |
| Capacity Range | 200–500 g |
| Readability | 0.1 mg |
| Calibration Method | Internal Automatic Calibration |
| Maximum Capacity | 252 g |
| Accuracy | ±0.3 mg |
| Repeatability | 0.2 mg |
| Stabilization Time | 2 s |
| Sensitivity Drift | ±2 ppm/°C (10–30 °C) |
| Operating Environment | 5–40 °C, RH <85% non-condensing |
| Display Update Rate | 5 or 10 Hz |
| Counting Mode Minimum Unit | 0.1 mg |
| Sample Count Options | 10 / 25 / 50 / 100 pcs |
| % Weighing Minimum Reference Weight | 10.0 mg |
| % Display Resolution | 0.01% / 0.1% / 1% |
| Interface | RS-232C |
| Software Compatibility | WinCT Data Acquisition Suite |
| External Calibration Weights | 250 g / 200 g / 100 g / 50 g |
| Pan Diameter | Ø90 mm |
| Draft Shield Dimensions | 193(W) × 262.5(D) × 84.5(H) mm |
| Power Supply | AC adapter (~11 VA), region-specific voltage compliance |
| Net Weight | ~3 kg |
| Brand | Artel |
|---|---|
| Origin | USA |
| Manufacturer | Artel, Inc. |
| Type | Imported Instrument |
| Model | Artel MVS |
| Pricing | Upon Request |
| Brand | Axel Semrau |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | CHRONECT XPR |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.01 mg (10 µg) |
| Repeatability | RSD ≤ ±10% at 1 mg |
| Calibration | Fully Automatic |
| Sample Throughput | Up to 32 powder samples and 6 liquid reagents per run |
| Environmental Operation | Inert gas-compatible (N₂/Ar), glovebox-integrated |
| Compliance | Designed for GLP/GMP environments with audit trail support |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | FA-2004 Precision Analytical Balance |
| Instrument Type | Precision Balance |
| Maximum Capacity | 200 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Pan Diameter | 90 mm |
| Calibration | Internal Automatic Calibration |
| Interface | RS232C Serial Output |
| Display | Backlit LCD with Large Font |
| Functions | Tare, Counting, Unit Conversion (g, ct, oz), Accumulation, Below-Balance Weighing, Adjustable Integration Time & Sensitivity |
| Power Supply | External AC Adapter |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer | AS ONE Corporation |
| Model No. | 2-5750-01 |
| Type | Mechanical Dual-Pan Centrifuge Tube Balancing Scale |
| Max. Tube Diameter | Ø35 mm |
| Pan Opening Diameter | Ø36 mm |
| Balance Base Material | Stainless Steel (SUS304) |
| Stand Material | PVC |
| Tube Holder Material | PMMA (Polymethyl Methacrylate) |
| Holder Dimensions | Ø50 × 86 mm |
| Net Weight | 820 g |
| Overall Dimensions (L×W×H) | 311 × 100 × 230 mm |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory balance verification workflows |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Model | FA1004 |
| Capacity | 100 g |
| Readability | 0.1 mg |
| Repeatability | ≤ 0.1 mg |
| Linearity | ±0.2 mg |
| Draft Shield Dimensions | 195 × 160 × 235 mm |
| Overall Dimensions | 195 × 445 × 300 mm |
| Pan Diameter | Φ90 mm |
| Power Options | AC adapter or 9 V battery |
| Interface | RS232 |
| Compliance | Designed for GLP/GMP-aligned laboratory workflows |
| Features | Electromagnetic force compensation sensor, internal calibration, dynamic temperature compensation, adjustable weighing speed, auto-zero tracking, overload protection, counting & percentage weighing, multi-unit conversion (g, oz, ct) |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Model | FA1104 |
| Capacity | 110 g |
| Readability | 0.1 mg |
| Repeatability | ≤ 0.1 mg |
| Linearity | ±0.2 mg |
| Pan Diameter | Ø90 mm |
| Draft Shield Dimensions | 195 × 160 × 235 mm |
| Overall Dimensions | 195 × 445 × 300 mm |
| Power Options | AC adapter or 9 V DC battery |
| Interface | RS232 |
| Features | Internal calibration, electromagnetic force compensation sensor, dynamic temperature compensation, adjustable counting mode, unit conversion (g, oz, ct), auto-zero tracking, overload protection, fault diagnostics |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Model | FA2004 |
| Capacity | 200 g |
| Readability | 0.1 mg |
| Repeatability | ≤ 0.1 mg |
| Linearity | ±0.2 mg |
| Pan Diameter | Φ90 mm |
| Draft Shield Dimensions | 195 × 160 × 235 mm |
| Overall Dimensions | 195 × 445 × 300 mm |
| Power Options | AC adapter or 9 V battery |
| Interface | RS232 |
| Compliance | Designed for GLP/GMP-aligned laboratory workflows |
| Brand | Chu Ding Technology |
|---|---|
| Model | JA1203 |
| Capacity | 120 g |
| Readability | 1 mg |
| Repeatability | ≤1 mg |
| Linearity | ≤±2 mg |
| Pan Diameter | Ø110 mm |
| Draft Shield Dimensions | 198 × 225 × 240 mm |
| Overall Dimensions | 212 × 330 × 323 mm |
| Power Options | AC adapter or 9 V DC battery |
| Display | Backlit LCD |
| Interface | RS232 |
| Compliance | ISO 9001-manufactured |
| Brand | Chu Ding Technology |
|---|---|
| Model | JA2003 |
| Capacity | 200 g |
| Readability | 1 mg |
| Repeatability | ≤1 mg |
| Linearity | ±2 mg |
| Pan Diameter | Ø110 mm |
| Draft Shield Dimensions | 198 × 225 × 240 mm |
| Overall Dimensions | 212 × 330 × 323 mm |
| Power Options | AC adapter or 9 V DC battery |
| Display | Backlit LCD |
| Interface | RS232 |
| Compliance | Designed for GLP-compliant environments |
| Key Features | Electromagnetic force compensation sensor, dynamic temperature compensation, adjustable weighing speed, auto-zero tracking, overload protection and alarm, multi-unit conversion (g, oz, ct), internal below-balance hook, counting mode, full-range tare |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Model | JA2003N |
| Capacity | 200 g |
| Readability | 1 mg |
| Repeatability | ≤1 mg |
| Linearity | ±2 mg |
| Dimensions (W×D×H) | 350 × 220 × 340 mm |
| Pan Diameter | Φ90 mm |
| Power | AC adapter or 9 V battery |
| Display | Backlit LCD |
| Interface | RS232 |
| Environmental Compensation | Dynamic temperature compensation |
| Features | Internal calibration, tare, counting mode, unit conversion (g, oz, ct), auto-zero tracking, overload protection & alarm, electromagnetic force sensor, 5-sided glass draft shield, 4-level shock absorption |
| Key | Capacity: 300 g |
|---|---|
| Readability | 1 mg |
| Repeatability | ≤1 mg |
| Linearity | ±2 mg |
| Pan Diameter | Φ110 mm |
| Draft Shield Dimensions | 198 × 225 × 240 mm |
| Overall Dimensions | 212 × 330 × 323 mm |
| Power Options | AC adapter or 9 V DC battery |
| Interface | RS232 |
| Display | Backlit LCD |
| Sensor Type | Electromagnetic force compensation (EMFC) |
| Environmental Compensation | Dynamic temperature compensation |
| Weighing Units | g, oz, ct, pcs, etc. |
| Key | Brand: Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Model | YP10001 / YP20001 / YP60001 |
| Capacity | 1000 g / 2000 g / 6000 g |
| Readability | 100 mg |
| Pan Size | Φ130 mm (YP10001/YP20001), 165 × 165 mm (YP60001) |
| Dimensions | 320 × 280 × 150 mm (YP10001/YP20001), 320 × 280 × 150 mm (YP60001) |
| Power Supply | AC/DC dual-mode |
| Interface | RS232C serial output |
| Brand | Chu Ding |
|---|---|
| Origin | Shanghai, China |
| Model | YP102N |
| Capacity | 100 g |
| Readability | 0.01 g |
| Repeatability | ≤0.01 g |
| Linearity | ±0.02 g |
| Pan Diameter | Φ128 mm |
| Draft Shield Dimensions | 175 × 170 × 185 mm |
| Overall Dimensions | 270 × 190 × 265 mm |
| Power | AC adapter or 9 V DC battery |
| Display | Backlit LCD |
| Interface | RS232 |
| Features | Auto-calibration, tare, counting mode, unit conversion, level indicator, full-range tare, built-in calibration weight |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | VWRI611-1565 |
| Liquid Capacity | 5–30 mL |
| Solid Capacity | 0–300 g |
| Resolution | 0.1 g |
| Accuracy | ±0.2 g or ±0.25% |
| Repeatability | ±0.1 g |
| Weighing Units | g, oz |
| Power | 2 × AAA batteries (≥1 year life) |
| Weight | 85 g |
| Dimensions (L×W×D) | 229 × 51 × 25 mm |
| Scoop Material | ABS plastic |
| Calibration Certificate | Traceable® to NIST, issued by A2LA-accredited ISO/IEC 17025:2005 laboratory |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CY220 |
| Price Range | USD 550–680 |
| Instrument Type | General-Purpose Analytical Balance |
| Capacity | 220 g |
| Readability | 0.001 g |
| Repeatability | ±0.001 g |
| Linearity | ±0.002 g |
| Pan Size | 128 × 128 mm |
| Stabilization Time | 2–3 s |
| Calibration | Automatic External Calibration |
| Weighing Units | g, mg, ct, oz, dwt, mom, GN |
| Tare Range | Full Capacity |
| Operating Temperature | 15–35 °C |
| Chamber Dimensions (W×D×H) | 210 × 300 × 145 mm |
| Net Weight | 4.1 kg |
| Power Supply | 230 V / 50 Hz |
| Compliance | GLP/GMP, ISO 9001 |
| Brand | D&A |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ES-J120D |
| Instrument Type | Density-Specific Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.1 mg |
| Repeatability | ±0.1 mg |
| Density Resolution | 0.0001 g/cm³ |
| Weighing Chamber Height | 210 mm |
| Pan Diameter | Φ90 mm |
| Operating Temperature Range | 13–25 °C |
| Operating Humidity Range | 20–85% RH (non-condensing) |
| Stabilization Time (Avg.) | ≤2.5 s |
| Warm-up Time | 30–60 min |
| Power Supply | 220 V AC / 50 Hz input |
| RS232 Baud Rates | 300, 600, 1200, 2400, 4800, 9600 |
| Construction | Stainless Steel Density Accessories |
| Compliance | Designed for GLP/GMP-aligned workflows, supports ASTM D792, ISO 1183, and USP <841> density determination protocols |
| Brand | D&A |
|---|---|
| Origin | Tianjin, China |
| Model | ES1035A |
| Max Capacity | 120 g |
| Readability | 0.01 mg |
| Repeatability | ±0.02 mg |
| Linearity | ±0.02 mg |
| Calibration | Automatic Internal Calibration |
| Stabilization Time | ≤2.5 s |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–80 %RH |
| Pan Diameter | Ø90 mm |
| Chamber Height | 230 mm |
| Display | Adjustable LCD (185 × 100 mm) |
| Interface | RS232 (300–9600 bps) |
| Power | 220 V AC / 50 Hz input |
| Accuracy Class | Class I (per OIML R76) |
| Brand | D&T |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JP1204 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.1 mg |
| Repeatability (5% load) | ±0.2 mg |
| Repeatability (near full load) | ±0.3 mg |
| Linearity Error | ±0.3 mg |
| Calibration Method | Internal (isoCAL) |
| Stabilization Time | ≤3 s |
| Pan Diameter | Φ90 mm |
| Dimensions (W×D×H) | 210 × 310 × 315 mm |
| Draft Shield Height | 210 mm |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–85% RH (non-condensing) |
| Temperature Drift | ≤5 ppm/°C |
| Warm-up Time | <15 min |
| Power Supply | 100–240 VAC, 50/60 Hz |
| DC Output | 12 VDC, 1 A |
| Communication Interface | RS232 (configurable baud rates: 300–9600) |
| Display | VA LCD |
| Environmental Compensation | Automatic temperature & time-triggered isoCAL |
| Shock Protection | Four-stage damping system |
| Accuracy Class | ISO 9001-compliant design |
| Brand | D&TC Dantec |
|---|---|
| Origin | Tianjin, China |
| Model | ES1200 |
| Maximum Capacity | 1200 g |
| Readability | 10 mg |
| Repeatability | ±10 mg |
| Linearity Error | ±10 mg |
| Stabilization Time | ≤2.5 s |
| Pan Diameter | Φ160 mm |
| Dimensions (W×D×H) | 210 × 310 × 90 mm |
| Operating Temperature | 13–25 °C |
| Operating Humidity | 10–70 % RH |
| Warm-up Time | 30–60 min |
| Power Input | 220 V AC / 50 Hz |
| Output | 7.5 V DC / 600 mA |
| RS232 Baud Rates | 300–9600 |
| Accuracy Class | Class II |
| Sensor Type | Gold-plated ceramic variable-capacitance transducer |
| Environmental Compensation | Integrated high-precision humidity & temperature sensors |
| Display | Backlit LCD with intuitive layout |
| Weighing Units | g, ct, oz, lb, etc. |
| Modes | Standard weighing, counting, percentage, checkweighing |
| Construction | Corrosion-resistant stainless-steel pan |
| Brand | D&T |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | XE2.7S |
| Instrument Type | Ultra-Micro Balance |
| Maximum Capacity | 2.1 g |
| Readability | 0.1 µg |
| Accuracy Class | Class I (per EU Directive 2014/31/EU) |
| Verification Scale Interval (e) | 1 µg |
| Minimum Weight (USP <41>) | 0.82 mg (recommended), 1.3 mg (typical) |
| Sensitivity Drift | 5 ppm/K (10–30 °C) |
| Tare Range | <100% of max capacity |
| Calibration | Internal (IsoCAL™ automatic temperature- and time-controlled calibration) |
| Stabilization Time | 8 s (typical) |
| Measurement Time | 12 s (typical) |
| Pan Diameter | Ø30 mm |
| Chamber Height | 80 mm |
| Dimensions (L×W×H) | 90 mm × 295 mm × 150 mm |
| Net Weight | ~4.7 kg |
| Operating Environment | 18–23 °C, 50–75% RH, temp. drift ≤1 °C/h |
| Power Supply | 100–240 VAC, 50/60 Hz, 0.5–1.0 A |
| Compliance | FDA 21 CFR Part 11 (ALCOA+ principles), GLP/GMP data integrity, OIML R111-1 E1 external calibration standard |
| Brand | D&T Corp |
|---|---|
| Origin | Tianjin, China |
| Model | ES8K |
| Maximum Capacity | 8000 g |
| Readability | 0.1 g |
| Repeatability | ±0.2 g |
| Linearity Error | ±0.2 g |
| Operating Temperature | 13–25 °C |
| Operating Humidity | 10–70 % RH |
| Response Time (avg.) | ≤2.5 s |
| Display Size | 185 × 100 mm |
| Pan Size | 370 × 310 mm |
| Dimensions (W×D×H) | 370 × 310 × 140 mm |
| Warm-up Time | 30–60 min |
| Power Supply | AC 220 V / 50 Hz → DC 7.5 V / 600 mA |
| Accuracy Class | Class II |
| Sensor Type | Gold-plated ceramic variable-capacitance transducer |
| Environmental Compensation | Integrated high-precision humidity & temperature sensors |
| Communication Interface | RS232 bidirectional |
| Weighing Modes | Standard, Piece Counting, Percentage, Checkweighing |
| Units | g, ct, oz, dwt |
| Construction | Anti-static, corrosion-resistant, spill-proof stainless steel pan and reinforced streamlined chassis |