| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZFA-1 |
| Price Range | USD 18,000 – 22,500 |
| Power Supply | AC 220 V, 50 Hz, ~0.5 kW |
| Exhaust Air Velocity | (2.5 ± 0.2) m/s |
| Fire-Resistant Porous Board Dimensions | (300 ± 10) mm × (450 ± 10) mm,耐900°C+ |
| Radiant Thermometer Range | 480–530 °C |
| Radiant Thermometer Accuracy | ±0.5% of reading |
| Thermocouple | 3.2 mm stainless steel sheathed type K |
| Heat Flux Meter Range | 0–15 kW/m² |
| Heat Flux Meter Accuracy | ±3% full scale |
| Heat Flux Meter Precision | ±0.2 kW/m² |
| Anemometer Accuracy | ±0.1 m/s |
| Timer Accuracy | <1 s/h |
| Overall Dimensions (L×W×H) | 2400 mm × 1340 mm × 3100 mm (incl. duct bend) |
| Specimen Size | (1050 ± 5) mm × (230 ± 5) mm (6 specimens per test series) |
| Conditioning Standard | EN 13238 |
| Igniter Gas Flow | (1.56 ± 0.12) L/min |
| Igniter Flame Height | 60–120 mm |
| Ignition Duration | 10 min at (10 ± 0.2) mm upstream of specimen zero point |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-150KV |
| Output Voltage | AC/DC 0–150 kV |
| Measurement Range | AC/DC 15–150 kV |
| Accuracy | ≤1% |
| Ramp Rate | 0.01–5 kV/s |
| Hold Time | 0–8 h |
| Leakage Current Setting | 1–30 mA |
| Input | AC 220 V ±10%, 50 Hz ±1% |
| Power Output | 15 kVA |
| Dimensions (L×W×H) | 1980 × 1220 × 1750 mm |
| Weight | 350 kg |
| Environmental Operating Range | 15–30 °C, RH ≤85% |
| Grounding Requirement | Dedicated earth electrode ≥1.5 m depth |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-150KV |
| Maximum Output Voltage | 150 kV |
| Compliance | GB/T 1408.1–2016, IEC 60243-1:2013, ASTM D149–20 |
| Electrode Configurations | Cylindrical (6.4 mm & 25 mm diameter), Parallel-plate, Needle-to-plate |
| Voltage Ramp Rates | 0.5–2 kV/s (adjustable) |
| Sample Thickness Range | 0.1–3 mm |
| Environmental Control | 23 ± 2 °C, 50 ± 5 % RH (optional oil bath or SF₆ gas chamber) |
| Safety Standards | IEC 61010-1, Dual Grounding, Interlocked Enclosure, Emergency Stop |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-212 Volume & Surface Resistivity Tester |
| Test Voltage Range | 10 V – 1000 V DC (7 precision-adjustable steps, ±1% accuracy) |
| Volume Resistivity Range | 1×10⁴ Ω·cm to 1×10¹⁸ Ω·cm (15 auto-ranging decades, ±5% accuracy at 23°C ±2°C, 50% RH ±5%, 100 V) |
| Surface Resistivity Range | 1×10³ Ω to 1×10¹⁷ Ω (14 auto-ranging decades, ±6% accuracy under same conditions) |
| Minimum Detectable Current | 1×10⁻¹⁴ A |
| Input Impedance | >1×10¹⁴ Ω |
| Electrode System | Tri-electrode configuration (guard, measuring, high-voltage electrodes) |
| Compliance | GB/T 1410–2006, GB/T 31338–2015, ASTM D257–14, IEC 60093:2016, JJG 690–2015 (Class II) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZY-2 |
| Application Field | Electrical & Electronic Equipment |
| Sample Type | Solid Materials |
| Repeatability Error | <1% |
| Compliance Standards | GB 4706.1-2005, GB/T 5169.5-2008, IEC 60695-11-5 |
| Flame Dimensions | Inner Diameter 0.5 mm ± 0.1 mm, Outer Diameter ≤ 0.9 mm, Length ≥ 35 mm |
| Flame Height | 12 mm ± 1 mm |
| Ignition Gas | 95% Butane (LPG compatible) |
| Flame Application Time | 0–999.9 s ± 0.1 s |
| Afterflame Time Measurement | 0–999.9 s ± 0.1 s, auto-recorded |
| Specimen Holder Positioning | Motorized X/Y/Z adjustment via touchscreen |
| Control System | PLC + 7-inch color touchscreen HMI |
| Combustion Chamber Volume | > 0.5 m³ (900 × 590 × 1050 mm) |
| Background Illuminance | ≤ 20 lux |
| Chamber Interior Finish | Matte black |
| Optional Accessories | Flame temperature calibration kit (K-type thermocouple, 0–1000 °C), gas leak alarm system |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50KV |
| Breakdown Voltage Range | 0–50 kV AC / DC |
| Voltage Accuracy | ≤1% |
| Test Medium | Air or Insulating Oil |
| Electrode Options | 25 mm, 75 mm, 6 mm spherical/plate electrodes |
| Ramp Rate | 0.1–3 kV/s (adjustable, continuous) |
| Test Modes | Stepwise ramp, constant-rate ramp, withstand voltage (0–6 h), gradient testing |
| Safety Protection | 9-level interlock system (overvoltage, overcurrent, short-circuit, door interlock, zero-voltage reset, post-test discharge, grounding, software lockout, electromagnetic discharge) |
| Power Input | 220 V AC, 5 kVA |
| Dimensions | 700 × 800 × 1300 mm (L×W×H) |
| Weight | ~150 kg |
| Compliance | GB/T 1408.1–2016, GB/T 1695–2005, GB/T 3333–1999, HG/T 3330, GB/T 12656–1990, ASTM D149, ASTM D3755 |
| Software | PC-based control with real-time curve plotting, data logging, audit trail, Excel/Word export, user access control, and GLP-compliant test report generation |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Output Voltage | AC/DC 0–100 kV |
| Output Power | 5 kVA |
| Voltage Measurement Accuracy | ≤ ±2% |
| Ramp Rate | 0.1–10 kV/s |
| Withstand Test Voltage Range | 10–100 kV (continuously adjustable) |
| Withstand Duration | 0–4 h (no-current condition) |
| Input | 220 V ±10%, 50 Hz ±1% |
| Dimensions (L×W×H) | 700 × 800 × 1650 mm |
| Weight | 100 kg |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 30–85% RH |
| Grounding Resistance Requirement | ≤ 4 Ω |
| Short-Circuit & Overcurrent Protection Response Time | ≤ 0.1 s |
| Compliance | GB 1408.1–2006, GB 1408.2–2006, GB/T 1695–2005, ASTM D149 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50kV |
| Breakdown Voltage Range | 0–50 kV (AC/DC) |
| Compliance | IEC 60243, ASTM D149, GB/T 1408, GB 16935 |
| Safety Features | Overvoltage/overcurrent protection, automatic discharge, interlocked enclosure |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZDH-20kV |
| Breakdown Voltage | 20 kV |
| Compliance Standards | IEC 61621, ASTM D495, GB/T 1411 |
| Electrode Spacing | 4 mm or 6.35 mm (adjustable) |
| Arc Current Range | 10–40 mA |
| Output Voltage | AC/DC, 0–20 kV |
| Safety Features | Interlocked arc chamber, emergency stop, grounding resistance ≤2 Ω |
| Calibration Interval | Semi-annual (±2% voltage accuracy) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RSJF-2 |
| Application Field | Electrical Wires and Cables |
| Test Object | Bundled Wire and Cable Assemblies |
| Primary Function | Fire Performance Evaluation per GB/T 31248–2014 and GB/T 18380.31–2008 (IEC 60332-3-10:2000 IDT) |
| Structural Dimensions (Overall Installation Space) | 2500 mm (W) × 4500 mm (D) × 5500 mm (H) |
| Net Weight | ~2500 kg |
| Power Supply | AC 220 V ±10%, 50 Hz, 7 kW |
| Cooling Water Requirement | Continuous supply with dedicated drainage |
| Fuel Source | Industrial propane with regulated flow (≥300 L/min compressed air via 3 kW air compressor) |
| Exhaust Handling | Integrated smoke collection and wet-scrubbing system compliant with local emission regulations |
| Safety Infrastructure | Requires 5-ton forklift, overhead crane, and three 5-m-height scaffolds for installation |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-150KV |
| Maximum Output Voltage | 150 kV AC/DC |
| Voltage Range | 0–100 kV AC/DC |
| Ramp Rate | 0.05–10 kV/s (continuously adjustable) |
| Measurement Accuracy | ≤1% for AC/DC voltage |
| Output Ripple Factor | ≤2% |
| Test Duration | 0–48 h (current-free mode) |
| Oil Bath Temperature Range | Ambient to 300 °C |
| Electrode Configurations | φ25 mm & φ75 mm stainless steel electrodes |
| Power Rating | 10 kW |
| Dimensions (L×W×H) | 1600 × 1100 × 1500 mm |
| Working Height | 940 ± 30 mm |
| Work Surface | 1600 × 1100 mm |
| Overcurrent Protection | 1–100 mA |
| Sampling Capacitor | 100 pF / 100 kV |
| Interface | Bilingual (English/Chinese) touchscreen + PC-based control software |
| Safety Compliance | IEC 61010-1, IEC 60243-1, GB/T 1408.1, ASTM D149, ISO 60243-1 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VFTA-2 |
| Price Range | USD 3,600 – 7,200 |
| Dimensions (W×D×H) | 1160 × 600 × 1250 mm |
| Combustion Chamber Volume | >0.5 m³ |
| Background | Matte Black, Illuminance ≤20 lux |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Rated Power | 150 W |
| Fuel Gas | Industrial propane, butane, or propane-butane mixture |
| Ignition Timer Range | 0–999.9 s |
| Burn Time Measurement Range | 0–999.9 s |
| Timing Resolution | 0.1 s |
| Flame Positioner Distances | 17 ±1 mm and 20 ±1 mm |
| Flame Height Calibration | 40 ±2 mm (vertical), 25 ±2 mm (horizontal) |
| Combustion Chamber Internal Dimensions | 900 × 600 × 1000 mm |
| Approx. Weight | 80 kg |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZJC-100KV |
| Price Range | USD 7,000 – 21,000 (FOB) |
| Maximum Output Voltage | 100 kV |
| Voltage Ramp Rate | 0.5–5 kV/s (continuously adjustable) |
| Voltage Measurement Range | 0–100 kV |
| Voltage Resolution | 1 V (10-bit A/D) |
| Breakdown Current Range | 0.1–100 mA |
| Current Accuracy | ±1% FS |
| Overvoltage Protection Threshold Accuracy | ±5% |
| Overcurrent Response Time | <1 ms |
| Flashover Auto-Restart Delay | 0–60 s (adjustable) |
| Safety Interlock Compliance | IEC 61010-1 |
| Data Sampling Rate | 500 Hz |
| Output Formats | CSV (raw), PDF (standard report) |
| Environmental Operating Conditions | 25±5°C, ≤65% RH |
| Electrode Material | Tungsten-Copper |
| Recommended Electrode Maintenance | Polishing with #800 grit sandpaper after every 50 tests |
| Transformer Oil Service Interval | Filtration required after 500 operating hours |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Max Output Voltage | 100 kV (AC/DC) |
| Input Voltage | AC 220 V ±10%, 50 Hz |
| Power Rating | 5 kVA |
| Voltage Regulation | Continuous, stepless (0–3000 V/s) |
| Voltage Measurement Accuracy | ≤ ±1% |
| Test Environments | Air or Transformer Oil Immersion |
| Safety Response Time | ≤ 0.01 s for overcurrent cutoff |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 0–85% RH (non-condensing) |
| Compliance | GB 1408.1–2006, GB 1408.2–2006, GB/T 1695–2005, GB/T 3333, GB 12656, ASTM D149, ASTM D876, DIN 53481, IEC 60243, UNI 4291 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTA-8 |
| Price Range | USD 3,500 – 7,000 |
| Application Field | Fire-Retardant Coatings |
| Test Objects | Plastics, Woven & Nonwoven Textiles |
| Repeatability Error | ±0.1 s |
| Compliance Standard | GB 14645–2014 (Equivalent to ISO 14054 for 45° flammability testing) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | FTA-8 |
| Display | 7-inch full-color TFT touchscreen (800×480 resolution, RS232 interface, FPGA-driven, zero boot time) |
| Combustion Chamber Dimensions | 660 mm × 660 mm × 1065 mm (L×W×H) |
| Flame Height Adjustment Range | 150–180 mm |
| Fuel Consumption Rate | 2.55 ± 0.15 mL/min |
| Flame Temperature Verification | 960 ± 60 °C at 50 mm from burner orifice (validated via 0.71 mm bare copper wire melt test within 6 s) |
| Timing Accuracy | ±0.1 s for both ignition and afterflame/afterglow duration |
| Repeatability Error | ±0.1 s |
| Fuel Composition | 5% (v/v) methanol + 95% (v/v) ethanol (user-prepared) |
| Construction | Electrostatically painted steel enclosure |
| Data Management | Internal storage (1 GB), historical test recall, automatic timing for ignition, flame-on, and afterflame/afterglow phases |
| Compliance Standards | MT 914–2008, GB 16413–2009, MT 113–1995 |
| Power Supply | 220 V ±10%, 50 Hz, 100 W |
| Ventilation Requirement | Mandatory fume hood or integrated exhaust & purification system |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | GBFS-1 |
| Supply Voltage | 220 V ±10%, 50 Hz |
| Power Consumption | 180 W |
| Temperature Range | 800 ±30 °C (max 900 °C, Class 1 accuracy) |
| Temperature Stabilization Time | <3 min |
| Flame Source | Dual LPG burners (inner diameter Φ9.5 ±0.5 mm, length ~100 mm |
| Gas Flow Control | 100–1000 mL/min |
| Load Application | 7, 10, 12, 15, 17, or 20 N (equivalent to 0.75–2.04 kgf) |
| Specimen Dimensions | 300 mm × 50 mm, with two 25-mm-offset suspension holes |
| Test Duration Resolution | 0.1 s |
| Repeatability Error | ±0.1 min |
| Ignition | Automatic electronic ignition |
| Temperature Monitoring | Dual thermocouples positioned 5 mm from specimen surface |
| Data Display | Digital real-time readout of temperature and elapsed time |
| Compliance Standard | GB/T 9775–2008 (identical to ISO 6308:1980) |
| Enclosure Dimensions | 700 × 300 × 600 mm (W×D×H) |
| Weight | ~30 kg |
| Ventilation Requirement | Mandatory fume extraction via ducted hood or integrated smoke treatment system |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZJD-B |
| Price Range | USD 4,200 – 11,200 (FOB Beijing) |
| Frequency Range | 1 kHz – 1 GHz (standard) |
| Dielectric Constant (ε′) Range | 1.0 – 35.0 (resolution: 0.1%) |
| Loss Tangent (tan δ) Range | 1×10⁻⁵ – 1.0 (resolution: 1×10⁻⁵) |
| Sample Compatibility | Solid discs (Ø20–100 mm, thickness 0.1–10 mm), liquids (parallel-plate or coaxial probe), thin films (3-electrode configuration) |
| Temperature Range | Ambient (23 °C ±1 °C) |
| optional thermal chamber | −50 °C to +150 °C |
| Voltage Gradient | 10–500 V/mm (adjustable per sample thickness) |
| Compliance | IEC 60250:2020, ASTM D150-18, GB/T 1409-2006 |
| Calibration | Open/short/load with NIST-traceable polystyrene reference dielectric and certified standard capacitors |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | SDC-2 |
| Chamber Volume | 27 m³ (3 m × 3 m × 3 m) |
| Light Source | 12 V, 100 W quartz-halogen lamp (400–750 nm) |
| Photodetector | Silicon photodiode |
| Transmittance Range | 0.0001–100% |
| Accuracy | ±3% |
| Power Supply | 220–240 V AC, 50 Hz, 4 kW |
| Operating Ambient | 15–40 °C, RH ≤85%, no direct sunlight or forced airflow |
| Compliance | GB/T 17651.1–2, IEC 61034-1–2 |
| Ignition System | Integrated automatic alcohol-based ignition |
| Software | Proprietary Windows-based transmittance acquisition and reporting suite with real-time curve plotting and GLP-compliant data export |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZST-212 High-Resistance Meter |
| Price Range | USD 2,800 – 7,000 |
| Standards Compliance | IEC 60093, ASTM D257, GB/T 31838.2–2019, IEC 62631-3-1, GB/T 1410–2006, GB/T 1692–2008 |
| Display | 4.3-inch HD TFT |
| Voltage Range | ±10 V to ±1500 V DC (continuously adjustable) |
| Resistance Measurement Range | 10⁶ Ω to 10¹⁸ Ω (standard configuration) |
| Minimum Detectable Current | 10 fA |
| Input Impedance | >10¹⁶ Ω |
| Leakage Compensation | Dual-channel active current-voltage feedback network |
| Interface Options | USB 2.0, RS-232C, Handler (TTL/PLC-compatible) |
| Safety Features | ATEX-compliant explosion-proof variant available |
| Environmental Operating Range | −20 °C to +55 °C (industrial grade), relative humidity ≤75% RH (non-condensing) |
| Warm-up Time | ≥30 min required for metrological validity |
| Measurement Modes | Automatic & manual |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-150KV |
| Maximum Output Voltage | 150 kV AC/DC |
| Voltage Accuracy | ≤ ±3–5% |
| Adjustable Ramp Rates | 0.1–5 kV/s (7 preset steps) |
| Test Modes | AC/DC — Uniform Ramp, Stepwise Ramp, Hold-at-Voltage (Dielectric Withstand) |
| Compliance | GB 1408.1–2006, GB/T 1695–2005, GB/T 3333–2008, HG/T 3330–2003, GB 12656–1990, ASTM D149–2022 |
| Electrode Configurations | Ø25 mm & Ø75 mm stainless steel disk electrodes |
| Test Medium | Air or insulating oil |
| Safety Interlocks | 6-level hardware-enforced shutdown (door switch, key-controlled HV disconnect, zero-position lockout, overcurrent cutoff <100 ms, ground fault detection, DC discharge alarm) |
| Software Platform | Windows XP/7/8 native application with real-time curve plotting, multi-curve overlay, region zoom, manual data validation, Excel export, user role management, and audit-trail-capable test logging |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJD-C |
| Frequency Range | 50 Hz – 1 MHz |
| Test Voltage | 0.1 kV – 10 kV |
| Temperature Control | Ambient to 300 °C |
| Sample Compatibility | Solid discs (Ø25–100 mm, thickness 0.1–10 mm), liquids, thin films |
| Measurement Accuracy | ε ≤ ±1%, tanδ ≤ ±1×10⁻⁴ |
| Compliance | IEC 60250, ASTM D150, GB/T 1409, IEEE 286 |
| Calibration | CNAS-accredited traceability |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Maximum Output Voltage | 100 kV |
| Compliance | GB/T 1408.1–2016, IEC 60243-1, ASTM D149 |
| Test Modes | Short-time, Stepwise (20 s/60 s), Ramp (120–600 s), Proof Testing |
| Electrode Configurations | Coaxial cylindrical, spherical, parallel plate, rod-to-rod, foil-wrapped tubular, and custom fixtures per ISO/IEC standards |
| Voltage Regulation Accuracy | ≤ ±2% of set value |
| Rise Time Control | Adjustable from 1 V/s to 5000 V/s |
| Measurement Uncertainty | ≤ ±3% (kV), traceable to national metrology standards |
| Safety Interlocks | Dual-channel overcurrent cutoff (<5 ms response), ground-fault detection, door-activated HV disable, arc-quenching chamber |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50kV |
| Dielectric Breakdown Voltage | 50 kV |
| Compliance | GB/T 1408.1, IEC 60243-1, ASTM D149 |
| Voltage Type | AC/DC selectable |
| Electrode Configuration | Standard spherical/cylindrical electrodes (brass) |
| Safety Enclosure | Interlocked grounded test chamber with emergency stop |