Beijing Aerospace Zhongheng Testing Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-150KV
Output VoltageAC/DC 0–150 kV
Measurement RangeAC/DC 15–150 kV
Accuracy≤1%
Ramp Rate0.01–5 kV/s
Hold Time0–8 h
Leakage Current Setting1–30 mA
InputAC 220 V ±10%, 50 Hz ±1%
Power Output15 kVA
Dimensions (L×W×H)1980 × 1220 × 1750 mm
Weight350 kg
Environmental Operating Range15–30 °C, RH ≤85%
Grounding RequirementDedicated earth electrode ≥1.5 m depth
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-150KV
Maximum Output Voltage150 kV
ComplianceGB/T 1408.1–2016, IEC 60243-1:2013, ASTM D149–20
Electrode ConfigurationsCylindrical (6.4 mm & 25 mm diameter), Parallel-plate, Needle-to-plate
Voltage Ramp Rates0.5–2 kV/s (adjustable)
Sample Thickness Range0.1–3 mm
Environmental Control23 ± 2 °C, 50 ± 5 % RH (optional oil bath or SF₆ gas chamber)
Safety StandardsIEC 61010-1, Dual Grounding, Interlocked Enclosure, Emergency Stop
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-50KV
Breakdown Voltage Range0–50 kV AC / DC
Voltage Accuracy≤1%
Test MediumAir or Insulating Oil
Electrode Options25 mm, 75 mm, 6 mm spherical/plate electrodes
Ramp Rate0.1–3 kV/s (adjustable, continuous)
Test ModesStepwise ramp, constant-rate ramp, withstand voltage (0–6 h), gradient testing
Safety Protection9-level interlock system (overvoltage, overcurrent, short-circuit, door interlock, zero-voltage reset, post-test discharge, grounding, software lockout, electromagnetic discharge)
Power Input220 V AC, 5 kVA
Dimensions700 × 800 × 1300 mm (L×W×H)
Weight~150 kg
ComplianceGB/T 1408.1–2016, GB/T 1695–2005, GB/T 3333–1999, HG/T 3330, GB/T 12656–1990, ASTM D149, ASTM D3755
SoftwarePC-based control with real-time curve plotting, data logging, audit trail, Excel/Word export, user access control, and GLP-compliant test report generation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-100KV
Output VoltageAC/DC 0–100 kV
Output Power5 kVA
Voltage Measurement Accuracy≤ ±2%
Ramp Rate0.1–10 kV/s
Withstand Test Voltage Range10–100 kV (continuously adjustable)
Withstand Duration0–4 h (no-current condition)
Input220 V ±10%, 50 Hz ±1%
Dimensions (L×W×H)700 × 800 × 1650 mm
Weight100 kg
Operating Temperature15–30 °C
Relative Humidity30–85% RH
Grounding Resistance Requirement≤ 4 Ω
Short-Circuit & Overcurrent Protection Response Time≤ 0.1 s
ComplianceGB 1408.1–2006, GB 1408.2–2006, GB/T 1695–2005, ASTM D149
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-50kV
Breakdown Voltage Range0–50 kV (AC/DC)
ComplianceIEC 60243, ASTM D149, GB/T 1408, GB 16935
Safety FeaturesOvervoltage/overcurrent protection, automatic discharge, interlocked enclosure
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZDH-20kV
Breakdown Voltage20 kV
Compliance StandardsIEC 61621, ASTM D495, GB/T 1411
Electrode Spacing4 mm or 6.35 mm (adjustable)
Arc Current Range10–40 mA
Output VoltageAC/DC, 0–20 kV
Safety FeaturesInterlocked arc chamber, emergency stop, grounding resistance ≤2 Ω
Calibration IntervalSemi-annual (±2% voltage accuracy)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-150KV
Maximum Output Voltage150 kV AC/DC
Voltage Range0–100 kV AC/DC
Ramp Rate0.05–10 kV/s (continuously adjustable)
Measurement Accuracy≤1% for AC/DC voltage
Output Ripple Factor≤2%
Test Duration0–48 h (current-free mode)
Oil Bath Temperature RangeAmbient to 300 °C
Electrode Configurationsφ25 mm & φ75 mm stainless steel electrodes
Power Rating10 kW
Dimensions (L×W×H)1600 × 1100 × 1500 mm
Working Height940 ± 30 mm
Work Surface1600 × 1100 mm
Overcurrent Protection1–100 mA
Sampling Capacitor100 pF / 100 kV
InterfaceBilingual (English/Chinese) touchscreen + PC-based control software
Safety ComplianceIEC 61010-1, IEC 60243-1, GB/T 1408.1, ASTM D149, ISO 60243-1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelZJC-100KV
Price RangeUSD 7,000 – 21,000 (FOB)
Maximum Output Voltage100 kV
Voltage Ramp Rate0.5–5 kV/s (continuously adjustable)
Voltage Measurement Range0–100 kV
Voltage Resolution1 V (10-bit A/D)
Breakdown Current Range0.1–100 mA
Current Accuracy±1% FS
Overvoltage Protection Threshold Accuracy±5%
Overcurrent Response Time<1 ms
Flashover Auto-Restart Delay0–60 s (adjustable)
Safety Interlock ComplianceIEC 61010-1
Data Sampling Rate500 Hz
Output FormatsCSV (raw), PDF (standard report)
Environmental Operating Conditions25±5°C, ≤65% RH
Electrode MaterialTungsten-Copper
Recommended Electrode MaintenancePolishing with #800 grit sandpaper after every 50 tests
Transformer Oil Service IntervalFiltration required after 500 operating hours
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-100KV
Max Output Voltage100 kV (AC/DC)
Input VoltageAC 220 V ±10%, 50 Hz
Power Rating5 kVA
Voltage RegulationContinuous, stepless (0–3000 V/s)
Voltage Measurement Accuracy≤ ±1%
Test EnvironmentsAir or Transformer Oil Immersion
Safety Response Time≤ 0.01 s for overcurrent cutoff
Operating Temperature15–30 °C
Relative Humidity0–85% RH (non-condensing)
ComplianceGB 1408.1–2006, GB 1408.2–2006, GB/T 1695–2005, GB/T 3333, GB 12656, ASTM D149, ASTM D876, DIN 53481, IEC 60243, UNI 4291
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-150KV
Maximum Output Voltage150 kV AC/DC
Voltage Accuracy≤ ±3–5%
Adjustable Ramp Rates0.1–5 kV/s (7 preset steps)
Test ModesAC/DC — Uniform Ramp, Stepwise Ramp, Hold-at-Voltage (Dielectric Withstand)
ComplianceGB 1408.1–2006, GB/T 1695–2005, GB/T 3333–2008, HG/T 3330–2003, GB 12656–1990, ASTM D149–2022
Electrode ConfigurationsØ25 mm & Ø75 mm stainless steel disk electrodes
Test MediumAir or insulating oil
Safety Interlocks6-level hardware-enforced shutdown (door switch, key-controlled HV disconnect, zero-position lockout, overcurrent cutoff <100 ms, ground fault detection, DC discharge alarm)
Software PlatformWindows XP/7/8 native application with real-time curve plotting, multi-curve overlay, region zoom, manual data validation, Excel export, user role management, and audit-trail-capable test logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-100KV
Maximum Output Voltage100 kV
ComplianceGB/T 1408.1–2016, IEC 60243-1, ASTM D149
Test ModesShort-time, Stepwise (20 s/60 s), Ramp (120–600 s), Proof Testing
Electrode ConfigurationsCoaxial cylindrical, spherical, parallel plate, rod-to-rod, foil-wrapped tubular, and custom fixtures per ISO/IEC standards
Voltage Regulation Accuracy≤ ±2% of set value
Rise Time ControlAdjustable from 1 V/s to 5000 V/s
Measurement Uncertainty≤ ±3% (kV), traceable to national metrology standards
Safety InterlocksDual-channel overcurrent cutoff (<5 ms response), ground-fault detection, door-activated HV disable, arc-quenching chamber
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-50kV
Dielectric Breakdown Voltage50 kV
ComplianceGB/T 1408.1, IEC 60243-1, ASTM D149
Voltage TypeAC/DC selectable
Electrode ConfigurationStandard spherical/cylindrical electrodes (brass)
Safety EnclosureInterlocked grounded test chamber with emergency stop
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-100KV
Breakdown Voltage Range0–100 kV (AC/DC)
Voltage Accuracy≤1%
Test MediaAir or Insulating Oil
Electrode Options25 mm, 75 mm, 6 mm (spherical, disk, rod configurations)
Power Capacity5 kVA or 10 kVA
Rise Rate10 V/s – 5 kV/s (continuously adjustable)
Safety Protection9-level interlocked protection system
ComplianceGB/T 1408.1–2006, GB/T 1695–2005, GB/T 3333–1999, ASTM D149, ASTM D3755, IEC 60243-1
Dimensions (Standard)700 × 800 × 1300 mm (L×W×H), 100 kg
Dimensions (Large)1900 × 1300 × 1700 mm (L×W×H), 200 kg
Input Voltage220 V AC, 50/60 Hz
Maximum Hold Time8 hours
Data InterfaceOptical-isolated acquisition, Bluetooth remote control
SoftwareWindows-based test management with real-time curve plotting, audit trail, export to Excel/Word, user access control, and GLP-compliant reporting
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-150KV
Output VoltageAC/DC 0–150 kV
Measurement RangeAC/DC 15–150 kV
Accuracy≤ ±2%
Ramp Rate1–5 kV/s
Hold Time0–4 h
Leakage Current Setting1–30 mA (software-controlled)
Input PowerAC 220 V ±10%, 50 Hz ±1%
Output Power15 kVA
Dimensions (L×W×H)1980 × 1220 × 1750 mm
Weight350 kg
Operating Environment15–30 °C, RH ≤ 85%
Grounding RequirementDedicated earth electrode ≥1.5 m depth
ComplianceGB 1408.1–2006, GB 1408.2–2006, GB/T 1695–2005, GB/T 3333, HG/T 3330, GB 12656, ASTM D149
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-50kV
Maximum Output Voltage50 kV
ComplianceIEC 60243, ASTM D149, IEC 60156, GB/T 13542
Electrode ConfigurationsSphere-Plate (Φ6 mm sphere vs. 25 mm plate) and Three-Electrode System
Temperature Control23 ± 2 °C
Relative Humidity Control50 ± 5 % RH
Voltage Waveform50 Hz AC sine wave (THD ≤ 5 %) or DC (ripple ≤ 3 %)
Safety EnclosureExplosion-resistant viewing window rated ≥ 75 kV
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-50kV
Maximum Output Voltage50 kV
Voltage Regulation Range0–50 kV AC/DC
Ramp Rate0.1–5 kV/s (adjustable)
Breakdown DetectionDual-threshold (current ≥1–10 mA + voltage drop >10%)
ComplianceIEC 60243-1, ASTM D149, GB/T 1408.1
Safety Enclosure1.5 mm 304 stainless steel shielded chamber (≥60 dB shielding effectiveness)
Data Acquisition100 kHz sampling rate
Environmental CompensationReal-time temperature/humidity correction (0.5%/°C)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-100KV
Maximum Test Voltage100 kV AC/DC
Voltage Accuracy≤2%
Rise Rate Range0.01–5 kV/s (adjustable in real time)
Test ModesAC/DC, stepwise ramp, withstand, breakdown
Electrode Options6 mm sphere, 25 mm & 75 mm flat disc electrodes
Test Mediumair or insulating oil
Safety Protection9-level interlocked protection system
Power Rating10 kVA
ComplianceGB/T 1408.1–2016, GB/T 1408.2–2006, GB/T 1695–2005, ASTM D149–2023
SoftwarePC-based control with real-time curve plotting, automatic breakdown detection, data logging, audit trail, and multi-sample parallel testing capability
Dimensions (L×W×H)1900 × 1300 × 1700 mm
Weight200 kg
Warranty3 years comprehensive, lifetime technical support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-50kV
Dielectric Breakdown Voltage Range0–50 kV
Input PowerAC 220 V ±10%, 50 Hz
Max Output Power3 kVA
Rise Rate Adjustment0.1–5 kV/s (adjustable)
Leakage Current Alarm ThresholdAdjustable (0.1–20 mA)
Voltage Accuracy±1.5% of reading (calibrated annually)
Operating Temperature0–40 °C
Relative Humidity≤80% RH (non-condensing)
Grounding Resistance Requirement≤4 Ω
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelDST-80kV
Breakdown Voltage Range0–80 kV AC (adjustable)
Voltage Accuracy±1%
Electrode Gap2.5 mm (calibrated with feeler gauge, tolerance ±0.1 mm)
Standard Electrodes12.5–13 mm diameter disc electrodes (brass or stainless steel, polished)
Test Cup MaterialIEC 60156-compliant ceramic or borosilicate glass
Cup Capacity~500 mL
Rise Rate0.5–5.0 kV/s (programmable)
Trip Current Threshold5 mA
Power Consumption≤200 W
Safety InterlockDoor-activated high-voltage cutoff
Grounding Resistance Requirement≤4 Ω
ComplianceIEC 60156:2025, ASTM D1816, GB/T 507–2002, DL/T 846.7–2004
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-150KV
Maximum Output Voltage150 kV
Voltage Ramp Rate0.1–3 kV/s (adjustable)
Electrode Configuration12.5 mm polished spherical electrodes (Ra ≤ 0.2 µm), fixed gap 2.5 mm ± 0.05 mm
Breakdown Current Threshold1–100 mA (programmable), response time ≤ 10 µs
Temperature ControlIntegrated oil bath, stability ±1 °C at 25 °C
Humidity Limit<70 % RH in test chamber
ComplianceIEC 60156, ASTM D877, GB/T 507, GB 2536
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-100KV
Maximum Output Voltage100 kV AC/DC
Voltage Accuracy≤ ±1%
Ramp Rate0.01–5.0 kV/s (adjustable)
Current Detection Threshold1–30 mA (configurable)
Trip Response Time≤ 0.1 s
Data Sampling Rate500 Hz
Test MediaAir, Insulating Oil
Standard Electrode Diameters6 mm, 25 mm, 75 mm
Power RatingUp to 10 kVA
Hold Time Range0–8 h
ComplianceIEC 60243-1, IEC 60243-2, GB/T 1408.1, GB/T 1408.2, ASTM D149, ASTM D877
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-100KV
Max Output Voltage100 kV AC/DC
Voltage Measurement Range0–100 kV (AC/DC)
Voltage Accuracy±1.5% (10–100% of full scale)
Rise Rate Adjustment0.1–3 kV/s (continuously variable, no gear shifting)
Test ModesRamp-up, Step-up, and Hold (with programmable dwell time up to 4 h, extendable per DIN/VDE/IEC conventions)
Power Rating10 kVA
Overcurrent Protection1–30 mA (software-configurable)
Safety FeaturesNine-level interlock system including overvoltage cutoff, door interlock, automatic discharge post-test, zero-voltage reset, independent grounding, short-circuit detection, and software operation validation
Dimensions (L×W×H)2100 × 1500 × 2100 mm
Net Weight1800 kg
ComplianceGB 1408.1–2006, GB 1408.2–2006, GB/T 1695–2005, ASTM D149, GB/T 3333, GB/T 12656, HG/T 3330
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelZH-50KV
Breakdown Voltage Range0–50 kV (AC/DC/Impulse)
Output Capacity≥10 kVA (compliant with GB/T 1408.1)
Voltage Accuracy≤1.5% FS (standard), optional ≤0.5% FS
Ramp Rate0.1–5 kV/s (adjustable), optional 0.01–10 kV/s (stepless)
Breakdown Detection Sensitivity0.1 mA (standard), optional 0.01 mA
Data Storage100 test records (standard), optional 1000+ with cloud backup
Safety ComplianceTriple Interlock Protection (door interlock, overcurrent cutoff ≤0.1 s, emergency stop), grounding resistance ≤4 Ω, discharge rod included
Environmental OptionsAmbient (15–40 °C, RH ≤70%), optional high-temp chamber (RT to 200 °C, ±1 °C), optional low-temp chamber (−70 °C), oil-immersion testing (25# transformer oil, oil bath available)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAerospace
OriginBeijing, China
ModelZJC-50KV
Maximum Output Voltage50 kV
ComplianceIEC 60243-2, GB/T 1408.2
Voltage Resolution0.1 kV
Ramp Rate Range0.1–5 kV/s (continuously adjustable)
Trip Current Threshold1–100 mA
Electrode OptionsIEC-standard spherical/cylindrical electrodes (6 mm or 25 mm diameter)
Environmental Control23 ± 2 °C, 50 ± 5 % RH
Measurement Accuracy±1 % of reading (voltage)