Empowering Scientific Discovery

Beijing Best Science & Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandACST
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelNLP-2000
PriceUSD 200,000
Instrument TypeMicroarray Chip System
Footprint4 cm × 4 cm × ~18 cm (H)
Substrate CompatibilitySilicon, SiO₂, Silanized Glass, Amine-Activated Slides, Metals, PDMS, Hydrogels, Polystyrene, Catalysts, Thiols
Minimum Feature Size10 nm
Patterning MethodDirect-Write Dip-Pen Nanolithography (DPN)
Printable MaterialsProteins, DNA/RNA, Antigens, Liposomes, Nanoparticles, Polyethylene Glycol (PEG), UV-Curable Polymers, Thermoset Polymers, Glycerol, Silanes
Viscosity Range1–20,000 cP
Print Area40 mm × 40 mm
ResolutionSub-100 nm lateral, <5 nm height control
Probe Array ConfigurationsSingle-tip to M-type multi-tip (up to 128 tips)
Environmental ControlIntegrated Humidity & Temperature Chamber (±0.1 °C, ±2% RH)
Motion StagesPiezoelectric XYZ linear stages + dual-axis goniometer (Tx/Ty)
ImagingHigh-resolution optical microscope (10×–100×, 0.7 µm resolution)
SoftwareACST NanoPattern Suite v4.2 (Scriptable, GLP-compliant audit trail, FDA 21 CFR Part 11 optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandACST
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelNanoFab
PriceUSD 200,000
Instrument CategoryMicroarray Fabrication System
Substrate MaterialSilicon
Substrate Dimensions2 cm × 2 cm
Feature Size5 µm
Probe Anchoring MethodAtomic Stamp (Soft Lithography-Based)
Compatible Sample TypesNucleic Acids, Proteins
Added to wishlistRemoved from wishlist 0
Add to compare
BrandACST
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelACST-AFM
Instrument TypeBiological AFM
Position Detection Noise≤0.15 nm RMS
Maximum Sample Size15 mm diameter
XY Stage Travel Range25 mm × 25 mm
SoftwareAotu AFM
Imaging ModesContact, Tapping, Phase, Lateral Force, Advanced Force Spectroscopy, Conductive AFM, Magnetic AFM, Nanolithography
XY Scanner Range>50 µm (closed-loop), <10 nm resolution (closed-loop), <1 nm resolution (open-loop)
Z Scanner Range>16 µm
Z Sensor Noise<5 nm
Z Feedback Noise<0.2 nm
Z ActuationDirect-drive stepper motor, 25 mm travel, 330 nm minimum step, 8 mm/min max speed
Optical System3 MP CCD camera, 45×–400× real-time magnification
Base MaterialSolid granite for vibration isolation and mechanical stability
Probe LoadingTool-free, rapid exchange design