Chip System/Accessories
Filter
Showing 1–30 of 64 results
| Brand | ACST |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | NanoFab |
| Price | USD 200,000 |
| Instrument Category | Microarray Fabrication System |
| Substrate Material | Silicon |
| Substrate Dimensions | 2 cm × 2 cm |
| Feature Size | 5 µm |
| Probe Anchoring Method | Atomic Stamp (Soft Lithography-Based) |
| Compatible Sample Types | Nucleic Acids, Proteins |
| Brand | ACST |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | NLP-2000 |
| Price | USD 200,000 |
| Instrument Type | Microarray Chip System |
| Footprint | 4 cm × 4 cm × ~18 cm (H) |
| Substrate Compatibility | Silicon, SiO₂, Silanized Glass, Amine-Activated Slides, Metals, PDMS, Hydrogels, Polystyrene, Catalysts, Thiols |
| Minimum Feature Size | 10 nm |
| Patterning Method | Direct-Write Dip-Pen Nanolithography (DPN) |
| Printable Materials | Proteins, DNA/RNA, Antigens, Liposomes, Nanoparticles, Polyethylene Glycol (PEG), UV-Curable Polymers, Thermoset Polymers, Glycerol, Silanes |
| Viscosity Range | 1–20,000 cP |
| Print Area | 40 mm × 40 mm |
| Resolution | Sub-100 nm lateral, <5 nm height control |
| Probe Array Configurations | Single-tip to M-type multi-tip (up to 128 tips) |
| Environmental Control | Integrated Humidity & Temperature Chamber (±0.1 °C, ±2% RH) |
| Motion Stages | Piezoelectric XYZ linear stages + dual-axis goniometer (Tx/Ty) |
| Imaging | High-resolution optical microscope (10×–100×, 0.7 µm resolution) |
| Software | ACST NanoPattern Suite v4.2 (Scriptable, GLP-compliant audit trail, FDA 21 CFR Part 11 optional) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer | Agilent Technologies |
| Country of Origin | Imported |
| Model | SureScan |
| Instrument Type | Microarray Scanning System |
| Dimensions | 43 cm (W) × 67 cm (D) × 42 cm (H) |
| Laser Wavelengths | 532 nm, 640 nm |
| Laser Class | Class 1 |
| Scan Resolutions | 2 µm, 3 µm, 5 µm, 10 µm |
| Pixel Positional Accuracy | <1 µm (at 5 µm resolution) |
| Compatible Dyes | Alexa 555, Alexa 647, Alexa 660, Cy3, Cy5 |
| Slide Format | Standard 1" × 3" (25 mm × 75 mm) glass slides, thickness 0.9–1.1 mm |
| Uniformity | ≤5% CV (global), ~1% (local, 100 µm features) |
| Detection Limit | 0.01 chromophore per µm² |
| Autofocus | Yes |
| Integrated Barcode Reader | Codabar, Code 128 (A/B/C), Code 39, Code 93 |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 15–85% RH |
| Max Altitude | 3000 m |
| Data Acquisition Time | 16 min (3 µm scan, 61 mm × 21.6 mm area), 24 min (2 µm scan) |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Compliance | ISO 13485-manufactured |
| Intended Use | For Research Use Only (RUO), Not for Diagnostic Use |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MPE-L2 / MPE-L3 |
| Pricing | Upon Request |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MPE-P1 |
| Chip Material | Stainless Steel 316 (SS316) |
| Control Interface | Integrated Industrial Touchscreen HMI |
| Data Management | Batch Logging, CSV Export, Audit-Trail-Ready Configuration |
| Flow Rate Range | Up to 50 mL/min per inlet (system-dependent) |
| Operating Pressure | ≤ 120 bar |
| Chip Compatibility | Custom SS316 microfluidic chips with asymmetric staggered herringbone or hydrodynamic focusing geometries |
| Brand | ArrayJet |
|---|---|
| Origin | United Kingdom |
| Model | Mercury 100 |
| Spotting Method | Non-contact piezoelectric inkjet |
| Spot Volume Range | picoliter to nanoliter (pL–nL) |
| Spotting Speed | 711 spots per second |
| Substrate Capacity | 6 × SBS-format microtiter plates or 100 standard microscope slides |
| Repeatability (CV) | < 5% |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with ISO 13485 and ASTM E2519-22 reference practices for microarray fabrication |
| Brand | ArrayJet |
|---|---|
| Origin | United Kingdom |
| Model | Mercury 100-S |
| Spotting Method | Non-contact piezoelectric inkjet |
| Spotting Speed | 711 spots/second |
| Substrate Capacity | 48 × SBS-format microplates or 100 × standard microscope slides (76 × 26 mm) |
| Spot-to-spot Precision | CV < 5% |
| Dispense Volume Range | picoliter to nanoliter |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with ISO 13485 and ASTM E2578-07 (Standard Guide for Microarray Processing) |
| Brand | ArrayJet |
|---|---|
| Origin | United Kingdom |
| Model | Mercury 1000 |
| Spotting Method | Non-contact piezoelectric inkjet |
| Spot Volume Range | picoliter to nanoliter (pL–nL) |
| Spotting Speed | 711 spots per second |
| Substrate Capacity | 6 × SBS-compliant microtiter plates or 1,000 standard microscope slides |
| Repeatability (CV) | < 5% |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with ISO 13485 and ASTM E2539-22 reference practices for microarray fabrication |
| Brand | ArrayJet |
|---|---|
| Origin | United Kingdom |
| Model | Mercury 1000-S |
| Spotting Method | Non-contact piezoelectric inkjet |
| Spot Volume Range | picoliter to nanoliter (pL–nL) |
| Spotting Speed | 711 spots per second |
| Substrate Capacity | 48 SBS-format microplates or 1,000 standard microscope slides |
| Positional Reproducibility | CV < 5% |
| Compliance | CE-marked, ISO 13485–compatible workflow design |
| Brand | Arrayjet |
|---|---|
| Origin | United Kingdom |
| Model | Mercury 100S |
| Spotting Type | Non-contact inkjet |
| Spot Volume Range | 40 pL to 10 nL |
| Certification | ISO 13485:2016 (Manufacturing Site, Edinburgh, UK) |
| Brand | ArrayJet |
|---|---|
| Origin | United Kingdom |
| Model | Mercury 25 |
| Spotting Method | Non-contact piezoelectric inkjet |
| Number of Parallel Nozzles | 128 |
| Spotting Speed | 711 spots per second |
| Substrate Capacity | 1 × SBS-standard microplate or 25 × standard microscope slides (76 × 26 mm) |
| Spot-to-Spot Reproducibility | CV < 5% |
| Environmental Control | Integrated humidity and temperature regulation with evaporation suppression |
| Brand | BEOnChip |
|---|---|
| Origin | Spain |
| Model | BE-DOUBLEFLOW |
| Chip Format | Standard Microscope Slide (75 × 25 mm) |
| Membrane Options | Polycarbonate or PET with customizable pore sizes (0.4 µm, 1.0 µm, 3.0 µm, 8.0 µm) |
| Fluidic Interface | Integrated Luer-lock inlets/outlets |
| Optical Compatibility | Fully transparent, high-clarity cyclic olefin copolymer (COC) body |
| Sterility | Gamma-irradiated, individually packaged |
| Compatibility | Compatible with Fluigent pressure-based systems, syringe pumps, inverted & upright microscopes (including phase contrast, fluorescence, and time-lapse imaging) |
| Brand | BeonChip |
|---|---|
| Origin | Spain |
| Model | BE-FLOW |
| Chip Format | Standard Microscope Slide-Sized (75.0 × 25.0 × 1.0 mm) |
| Channel Architecture | Dual Independent Parallel Channels |
| Flow Control | Independent Pressure-Driven Shear Regulation per Channel |
| Cell Culture Compatibility | 2D Monolayer & 3D Hydrogel-Embedded Cultures |
| Surface Treatment | Non-Fouling, Low-Adsorption Polymer Coating |
| Sterility | Pre-Sterilized (EO or Gamma, upon request) |
| Regulatory Status | For Research Use Only (RUO) |
| Brand | BEOnChip |
|---|---|
| Origin | Spain |
| Model | BE-GRADIENT |
| Chip Format | Standard microscope slide footprint (75 × 25 mm) |
| Chamber Architecture | One central 3D culture chamber + three integrated microchannels (two lateral perfusion channels + one auxiliary channel) |
| Substrate Material | Optical-grade, plasma-bonded cyclic olefin copolymer (COC) |
| Transparency Range | 200–1100 nm (fully compatible with brightfield, phase contrast, DIC, and fluorescence microscopy) |
| Sterility | Pre-sterilized via ethylene oxide (EO) gas |
| Surface Treatment | Non-fouling, cell-adhesion-neutral coating (no extracellular matrix pre-coating required) |
| Fluidic Interface | Standard Luer-lock connectors (1/4"-28 thread) |
| Compatibility | Compatible with syringe pumps (e.g., Harvard Apparatus PHD Ultra), pressure-driven systems (e.g., Elveflow OB1), and automated perfusion platforms |
| Brand | BEOnChip |
|---|---|
| Origin | Spain |
| Model | BE-TRANSFLOW |
| Form Factor | Standard Microscope Slide (75 × 25 mm) |
| Membrane | Integrated Porous Polycarbonate or PET Membrane (Typical Pore Sizes: 0.4 µm, 3.0 µm, 8.0 µm — Configurable) |
| Chamber Configuration | Dual Independent Culture Wells Connected via Sub-membrane Microchannel Network |
| Optical Compatibility | Fully Transparent, High-Clarity Polymer (Cyclic Olefin Copolymer, COC) |
| Fluidic Interface | Standard Luer Lock Inlets/Outlets (Compatible with Fluigent, Elveflow, Harvard Apparatus, and Other Pressure/Peristaltic/Syringe Pump Systems) |
| Sterility | Pre-sterilized (EO or Gamma), Ready-to-Use |
| Regulatory Status | For Research Use Only (RUO) |
| Brand | Bo-Semitech |
|---|---|
| Origin | Guangdong, China |
| Chip Material | Organic Polymer |
| Chip Type | Continuous-Flow Microfluidic Chip |
| Target Analytes | Proteins |
| Detection Sensitivity | 1–10 pg/mL (e.g., IL-6) |
| Dynamic Range | 1–1000 pg/mL (R² > 0.99) |
| Readout Format | Portable Fluorescence Reader or Smartphone-Coupled Imaging Module |
| Multiplex Capacity | Up to 16 Analytes per Chip |
| Regulatory Classification | In Vitro Diagnostic (IVD) Microfluidic Platform |
| Compliance Context | Designed for CLIA-waived and point-of-care use under ISO 13485-aligned manufacturing practices |
| Brand | Bo-Semitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Xinqiji JX-8B |
| Price | USD 42,000 (FOB Guangdong) |
| Detection Principle | Single-Molecule Array (Simoa) Technology |
| Assay Time | ≤10 min per run |
| Analyte Range | 0.054–1000 pg/mL (IL-6) |
| LOD (IL-6) | 0.054 pg/mL |
| LOD (PCT) | <10 pg/mL |
| Linearity (R²) | >0.99 across multiplex panels |
| Intra-assay CV | <16.2% (n=16) |
| Multiplex Capacity | Up to 8 human or murine cytokines per chip |
| Compatible Biomarkers | Human IL-4, IL-5, IL-8, TNF-α, IL-6, IFN-γ, IL-1β |
| Brand | Dolomite |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Dolomite MicroFluidics |
| Pricing | Available Upon Request |
| Droplet Size Range | 50–200 µm |
| Emulsion Types | (o/w/o, w/o/w) |
| Flow Rate Range | 70 nL/min to 5 mL/min |
| Precision Control | Yes |
| Reproducibility | High |
| Primary Applications | Drug Delivery, Enzyme Immobilization, Taste Masking in Food, Cosmetic Active Delivery, In Vitro Encapsulation, Flow Cytometry Beads, Microcapsule Carriers |
| Brand | Dolomite |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Telos® |
| Operating Pressure Range | 0–10 bar (150 psi) |
| Temperature Control Range | 4–80 °C |
| Maximum Parallel Modules | 10 |
| Channels per Module | 7 |
| Total Parallel Channels (with Support Frame 3200375) | 70 |
| Illumination | Dual-side (top & bottom) optical access |
| Integrated Flow Control | On-chip pneumatic valves |
| Output Configuration | Bulk reservoir or parallel tubing collection |
| Brand | Dolomite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Mitios-1 |
| Pricing | Available Upon Request |
| Droplet Diameter Range | 10–250 µm |
| Droplet Generation Rate | >10,000 Hz |
| Flow Control | Independent Dual-Channel Pressure-Driven Actuation |
| Max Operating Pressure | 10 bar |
| Pump Type | Pulse-Free Pressure-Driven Microfluidic Pump |
| Chemical Resistance | High (Compatible with Organic Solvents, Acids, Bases) |
| Chip Interface | Standardized PDMS/Glass/Si Modular Cartridge Format |
| Fluid Compatibility | Aqueous, Oil, Surfactant-Stabilized, Viscous (up to 500 mPa·s) |
| Customization | Fully Configurable Chip Geometry, Channel Dimensions, Surface Chemistry, and Integration Ports |
| Brand | Dolomite |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Mitios-1 |
| Chip Material | Organic Polymer |
| Chip Type | Droplet-Based Microfluidic Chip |
| Droplet Diameter Range | 10–250 µm |
| Droplet Generation Rate | >10,000 Hz |
| Flow Control | Independent Dual-Channel Pressure-Driven Actuation |
| Max Operating Pressure | 10 bar |
| Chemical Resistance | High (Compatible with Common Organic Solvents, Aqueous Buffers, and Surfactant Solutions) |
| System Architecture | Modular, Reconfigurable, and Chip-Interchangeable |
| Brand | Dolomite |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Mitos |
| Chip Type | Not Specified |
| Chip Material | Not Specified |
| Detection Limit | Not Specified |
| Channel Dimension | Not Specified |
| Analyte Range | Not Specified |
| Brand | Dolomite |
|---|---|
| Origin | United Kingdom |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | Drug Encapsulation System for PLGA Nanoparticles |
| Chip Type | Single-use microfluidic chip |
| Chip Material | Glass/PDMS hybrid (biocompatible, solvent-resistant) |
| Detection Limit | Not applicable (system is a fabrication platform, not an analytical instrument) |
| Channel Dimension | 1–100 µm (customizable per application) |
| Target Payload | Hydrophobic/hydrophilic small-molecule drugs, peptides, siRNA, and other therapeutic actives encapsulated in PLGA |
| Brand | FluidicLab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Producer |
| Region of Origin | Domestic (China) |
| Model | LNP-B1 (with Luer Fitting) |
| Chip Material | Cyclic Olefin Copolymer (COC) |
| Chip Type | Droplet-Generation Microfluidic Chip |
| Dimensions (mm) | 62.2 × 41.3 |
| Channel Width | 350–700 µm |
| Max Operating Pressure | 50 bar |
| Total Fill Volume | 8.22 µL |
| Mixing Structure Volume | 2.09 µL |
| Recommended Total Flow Rate | 16 mL/min |
| Maximum Total Flow Rate | 40 mL/min |
| Compatible Instruments | FluidicLab LNP-S1 & LNP-S2 Intelligent Lipid Nanoparticle Synthesizers |
| Application Range | Total Synthesis Volume 0.4–40 mL |
| Flow Regime | Medium-volume, medium-flow-rate LNP formulation |
| Brand | FluidicLab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Producer |
| Product Category | Domestic |
| Model | PDMS-HTS-80 |
| Price | USD 185 (excl. VAT & shipping) |
| Chip Material | Covalently bonded PDMS microchannels on borosilicate glass substrate |
| Chip Type | Step-emulsion droplet generation chip |
| Channel Width | 160 µm |
| Nozzle Geometry | Parallel stepped orifice array (188 independent units) |
| Droplet Diameter Range | 80–100 µm |
| Aqueous Phase Flow Rate Range | 10–1000 µL/min (CV < 5% under stable pressure control) |
| Substrate Dimensions | 75 × 25 × 2 mm (glass), Chip Active Area: 62 × 19 × 2 mm |
| Surface Treatment | Hydrophobic silanization of PDMS channels |
| Operational Configuration | Dual-inlet/dual-output symmetric layout (Chip I: Inlets ①/② → Outlet ③ |
| Chip II | Inlets ④/⑤ → Outlet ⑥) |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | FRP Flow Rate Platform (comprising FLOW UNIT sensor + FLOWBOARD controller) |
| Flow Range Options | 7 nL/min to 5 mL/min |
| Sensor Types | XS, S, M, L, XL |
| Communication Interface | USB |
| Max Channels per FLOWBOARD | 8 |
| Software | Fluigent AIO (All-in-One) v3.x |
| Compliance | CE-marked, RoHS-compliant, designed for GLP-compatible lab environments |
| Instrument Category | Microfluidic Chip System |
| Integration | Standalone or embedded in pressure-driven microfluidic control setups |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Fluigent-PLGA |
| Chip Type | Raydrop™ |
| Chip Material | Fluorinated Ethylene Propylene (FEP) with Integrated Glass Viewing Window |
| Detection Limit | Sub-micron droplet resolution via high-speed digital microscopy |
| Channel Dimensions | 1–50 µm (standard Raydrop chip configurations) |
| Target Analyte | Poly(lactic-co-glycolic acid) (PLGA) micro/nanoparticles |
| Solvent Compatibility | Ethyl acetate, dichloromethane, acetonitrile, and other low-surface-tension organic solvents |
| Brand | GLASER |
|---|---|
| Origin | Jiangsu, China |
| Model | SMART ETCH UV |
| Laser Wavelength | 355 nm |
| Pulse Width | 10 ± 5 ns @ 40 kHz, 20 ± 5 ns @ 100 kHz |
| Average Power | 7 W @ 60 kHz |
| Pulse Energy | 125 µJ |
| Output Power Range | 1–100% |
| Max Scanning Area | 110 mm × 110 mm |
| Beam Quality (M²) | ≤ 1.2 |
| Scan Speed | 13,000 mm/s |
| Delidding Speed | ≥ 3,000 mm/s |
| Single-Pass Depth Control | 0.01–1.0 mm |
| Sample Height Range | 0.5–70 mm |
| Camera Resolution | 20 MP color CCD |
| Filtration Efficiency | >98% for particles ≥ 0.3 µm |
| Operating Gas | Compressed air or N₂, 0.3 MPa |
| Safety Class | Class I (interlocked) |
| Dimensions (W×D×H) | 730 × 1100 × 1600 mm |
| Weight | 280 kg |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | HG-20001 |
| Instrument Category | Microfluidic Chip System |
| Detection Principle | Laser-Induced Fluorescence (LIF) with Confocal Optical Path |
| Sensitivity | 10⁻⁹ M (FITC) |
| Migration Time Repeatability | RSD ≤ 1.54% (n = 10, FITC) |
| High-Voltage Power Supply | 0–6000 V (no current display) |
| Optical Alignment Resolution | 0.25 arcmin per 360° rotation |
| Operating Temperature | Ambient |
| Laser Source | Solid-State Laser |
| Filter Set | Bandpass, High-Pass, Low-Pass (complete set) |
| Photomultiplier Tube (PMT) | Single-Photon Detection Capability |
| Electrode Configuration | 4/6/8 Pt electrodes |
| Inverted Microscope | 40× magnification |
| Power Requirement | 220 V, 50 Hz |
| Software Compatibility | Windows 98/2000/XP |
| Dimensions (W × D × H) | 28 × 33 × 45 cm |
| Weight | 20 kg |
| Brand | INNOPSYS |
|---|---|
| Origin | Germany |
| Model | InnoQuant |
| Laser Wavelengths | 375 nm, 488 nm, 561 nm, 640 nm |
| Detection Channels | 4 independent PMT detectors |
| Filter Wheels | 7-position per channel |
| Spatial Resolution | 0.5 µm/pixel |
| Scan Area | 18 mm × 18 mm (full slide, no tiling) |
| Scan Time | ≤17 min @ 0.5 µm/pixel |
| Output Format | 8-bit or 16-bit TIFF |
| Imaging Mode | Point-scanning confocal |
| Z-axis Auto-focus | Real-time dynamic focus tracking |