| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | 960A |
| Instrument Type | Multifunctional Autosampler |
| Sample Introduction Ports | 16-position |
| Compatible Sample Containers | Vacuum Sampling Canisters & Tedlar® Bags |
| Entire Gas Path Heating | Yes (Uniform Temperature Control) |
| Gas Path Surface Treatment | Fused Silica Inert Coating (Verified via Inertness Testing) |
| Multi-Position Injection Valve | Bidirectional Rotational Actuation |
| Flow Path Optimization | Minimized Contact Time Between Sample and Valve Core |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HS-E2 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Pricing | Available Upon Request |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 960SN |
| Instrument Type | Multifunctional High-Pressure Autosampler |
| Pricing | Upon Request |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BCT950M |
| Instrument Type | Multifunctional Autosampler |
| Maximum Sample Capacity | 5–1000 mL (standard configuration) |
| Sampling Mechanism | Canister-based automated sampling |
| Sample Loop Volume Range | 0.1 µL – 30 mL |
| Transfer Line Length | < 0.5 m |
| Transfer Line Max Temperature | > 200 °C |
| Sample Path Surface Treatment | Deactivated fused-silica throughout |
| Focusing Trap | Integrated independent cryo-focusing trap for secondary focusing of loop- or trap-desorbed analytes |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Oven Temperature Range | Ambient to 225 °C |
| Valve & Transfer Line Temperature Range | Ambient to 225 °C |
| Sample Loop Volume | 1 mL |
| Sample Position Capacity | 12 positions |
| Vial Sizes Supported | 10 mL and 20 mL vials |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | BCT-700 |
| Temperature Control Range | 0–45 °C (ambient operating environment) |
| Gas Flow Rate | 0.1 MPa, 100 mL/min ±5 mL/min |
| Tube Capacity | 21 positions (3 independent zones × 7 tubes each) |
| Aging Zone Temperature Range | Ambient to 400 °C ±1 °C |
| Vaporization Zone Temperature Range | 0–200 °C ±1 °C |
| Aging Time Setting | 0–999 min |
| Sample Introduction Flow (Calibration Standard Prep) | 0–100 mL/min ±1 mL/min |
| Input Pressure Limit | ≤0.4 MPa |
| Power Supply | AC 220 V, 50–60 Hz, 400 W |
| Dimensions | 380 × 270 × 230 mm |
| Weight | ≤10 kg |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | 5–220 °C |
| Valve & Loop Temperature Control Range | 5–220 °C |
| Sample Loop Volumes | 0.5 mL, 1 mL, 3 mL |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity | 46 positions |
| Vial Sizes Supported | 10 mL and 20 mL |