BrandADEV
OriginBeijing, China
Model7600
Measurement GasesO₂ (0–5% vol), CO (0–85% vol), H₂ (0–15% vol)
Accuracy≤±1% FS for O₂
Response Time≤15 s
Dust Tolerance≤600 g/Nm³
Operating Temp.20–500 °C
Pressure Range−10 to +10 kPa
Filtration Precision0.1 µm
Auto-CleaningYes (pneumatic probe & filter blowback)
Output Signals4–20 mA analog + relay alarm (1 A, dry contact)
ComplianceDesigned for GLP-aligned industrial process safety monitoring in metallurgical environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADEV
OriginItaly
Model8864
Measurement PrincipleElectrochemical Zirconia Oxidation Potential
Sensor TypeBuilt-in Heated Zirconia Cell
Range Options0–100 ppm / 0–1000 ppm / 0–1% / 0–2% / 0–5% / 0–10% / 0–25% / 50–100% / 80–100% / 90–100% / 95–100% / 98–100%
Display0.75″ (19.05 mm) High-Brightness LCD
Accuracy±1% FS
Response Time (T90)<15 s
Warm-up Time~2 min
Operating Temperature5–45 °C
Output SignalsRS-232, 4–20 mA (500 Ω load), 0–10 VDC (also configurable as 0–1 VDC or 0–5 VDC)
Alarm Outputs2 SPDT relays, programmable for high/low limit
Sample Flow Rate250–1000 mL/min
Sample Connection1/4″ or 6 mm compression fitting
Power Supply (Transmitter)115/230 VAC, 50/60 Hz, 50 VA
Power Supply (Display Controller)115/230 VAC, 50/60 Hz
Enclosure RatingII GD EEx-d IIC T6 IP65
Max Surface Temperature≤85 °C
Weight (Explosion-Proof Version)8.5 kg
Warranty1 year
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADEV
OriginBeijing, China
ModelMODEL3750
Instrument TypeOnline Continuous Emission Monitor
Detection PrincipleDual-Beam NDIR (Non-Dispersive Infrared) + Electrochemical (EC) + Thermal Conductivity (TCD) + Photoionization (PID) Sensor Modules
Measurable GasesCO, CO₂, CH₄, C₂H₄, C₃H₈, C₄H₁₀, H₂, O₂, NO, NO₂, N₂O, NH₃, SO₂, H₂S, SF₆, Ar, He, BrCH₃, SO₂F₂, HC (hydrocarbons)
Range Options0–100 ppm to 0–100% vol (user-selectable per channel)
Minimum Detectable Range0–20 ppm
Resolution0.1 ppm
Repeatability±1% FS
Zero Drift±2% FS / 7 days
Span Drift±1% FS / 7 days
Linearity Error±2% FS
Response Time (T₉₀)≤10 s (for most NDIR channels), ≤30 s (for EC/TCD/PID)
ComplianceCE-marked
Output Interfaces4–20 mA analog (isolated), RS232, RS485, CAN bus
Data LoggingInternal non-volatile memory (≥100,000 records), timestamped with real-time clock
Display & UI320×240 monochrome LCD, full Chinese menu, five-key navigation
Enclosure19-inch rack-mount chassis (4U height), IP20 rated
Power Supply220 VAC ±10%, 50/60 Hz
Operating Temperature5–40 °C
Humidity Range20–80% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADEV
OriginItaly
ModelOxyTrend
Measurement PrincipleElectrochemical (Galvanic or Zirconia-based, configurable)
Range Options0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–10,000 ppm, 0–25% O₂
Accuracy±1% of full scale
Linearity>0.995 across all ranges
Response Time (t₉₀)15 s
Detection Limit100 ppb
Temperature CompensationYes
Pressure CompensationYes
Operating Temp.5–45°C (TO2 series), –20–45°C (PO2 series)
Sample Flow Rate0.25–2.5 L/min (recommended: 1 L/min)
Inlet Pressure0–3 MPa
Output4–20 mA analog
Alarm Outputs2 relay outputs
DisplayBacklit LCD, resolution 0.01 ppm
Enclosure RatingIP65
ATEX CertificationII 2 G D Ex db IIC T6 Gb / Ex tb IIIC T85°C Db (Zone 1 / Zone 21)
Sensor Lifetime24 months at 25°C
Warranty12 months (instrument & sensor)
Wetted Materials316L stainless steel
CalibrationCertified standard gas at ~80% FS
Sensor OptionsTO2-1x (ppm-level, H₂S/CO₂ tolerant), TO2-2x (enhanced ppm-level), PO2-160 (percent-level), PO2-24 (percent-level, H₂S/CO₂ tolerant)
Power Supply9–28 VDC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADEV
OriginUnited Kingdom
ModelEC2000D
Measurement PrincipleElectrochemical Fuel Cell (Galvanic)
Measurement Ranges0.00–1%, 0–2%, 0–5%, 0–10%, 0–25%, 0–100% O₂
Accuracy≤ ±1% FS
Repeatability≤ ±1% FS
Resolution0.01% O₂
Stability±1% FS over 7 days (zero & span drift)
Response Time (T90)≤10 s
Operating Gas Temperature–5 to +45 °C
Ambient Temperature Range–5 to +45 °C
Relative Humidity0–90% RH (non-condensing)
Power Supply220 VAC ±10%, 50 Hz ±10%
Sample Inlet Pressure0.003–0.1 MPa (requires external conditioning)
Sample Flow Rate100–1000 mL/min (requires external conditioning)
Explosion ProtectionATEX II 2G D EEx d IIB T6 Gb / II 2D EEx t IIIA T85 °C IP65
CertificationsATEX Directive 2014/34/EU, IEC 60079-0, IEC 60079-1, IEC 60079-31
Hazardous Area ClassificationZone 1 (gas), Zone 21 (dust)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADEV
Model8866TR
OriginItaly
Explosion-Proof RatingATEX 94/9/EC, CSA Certified
Enclosure RatingIP66
Measurement PrincipleThermal Conductivity (TCD)
Range Options0–1% to 0–100% H₂ (also configurable for He, CH₄, CO, N₂, Ar, CO₂ in binary/ternary/quaternary gas mixtures)
Accuracy±1% FS
Repeatability≤0.3% FS
Linearity Error≤1% FS
Response Time (t₆₀)H₂ < 13 s, CO₂ < 23 s
Flow Rate100 mL/min – 2 L/min
Sample Connection1/4" or 6 mm compression fitting
Analog OutputsUp to four isolated 4–20 mA
Digital InterfaceRS232 / RS485
Power Supply24–30 VDC (sensor), or 115 VAC ±10% / 220 VAC ±20%, 50 ±0.5 Hz, 150 VA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADEV
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelOMD-625
Price RangeUSD 4,200 – 7,000
Sensor TechnologyElectrochemical Fuel Cell (ppm to % range)
Measurement Range Options0–1 ppm, 0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–10,000 ppm, 0–25%, 0–100%
Accuracy< ±1% of reading
Response Time (t₉₀)≤15 s
Operating Temperature5–45°C (TO2 series), –20–45°C (PO2 series)
Pressure Range0–3 MPa inlet, vent to atmosphere
Sample Flow Rate0.25–2.5 L/min (recommended: 1.0 L/min)
Output Signal4–20 mA analog
Power Supply9–28 VDC
Enclosure RatingClass I, Division 1, Groups B, C, D (UL/cUL listed)
CertificationsCE, ATEX/IECEx equivalent intrinsic safety (IS) approval
DisplayBacklit LCD, 0.01 ppm resolution
Linearity>0.995 across all ranges
Temperature & Pressure CompensationBuilt-in
Alarm Outputs2 SPDT relays
CalibrationSpan calibration using certified gas at ~80% of selected range
Wetted Materials316 stainless steel
Sensor Lifetime24 months at 25°C
Warranty12 months (instrument + sensor)
ComplianceDesigned for GLP/GMP-relevant environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADEV
OriginItaly
ModelEC2000
DisplayMulti-digit LCD, character height 12.7 mm
Measurement Range0.01 ppm – 100% O₂ (auto-ranging)
Resolution0.01 ppm (0.00–9.99 ppm)
Accuracy±1% of reading or ±1 mV sensor output (whichever is greater)
StabilityBetter than ±2% of full scale per month
Sample Flow RateOptimal 100–300 mL/min
Response Time (T₉₀)≤4 s at 300 mL/min
Sample Inlet Pressure (without pump)10 mbar – 8 bar
Sample Temperature LimitUp to 100 °C at analyzer inlet
Gas ConnectionNickel-plated brass compression fittings (6 mm OD / 0.25″), dual-clamp brass or stainless steel unions
Analog OutputIsolated 0–5 V (min. load 10 kΩ) or 4–20 mA (max. load 500 Ω)
Alarm Outputs2 configurable relays (high/low/off mode
contact rating48 V AC/DC, 0.5 A, normally energized
Communication InterfaceRS-232 DCE
Operating Environment0–45 °C, 15–90% RH (non-condensing)
Power Supply90–130 V AC or 200–260 V AC, 50/60 Hz (configurable at order)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADEV
OriginBeijing, China
ModelFY-1000
Instrument TypeFixed-mount online analyzer
Detection TargetsO₂, CH₄, CO, CO₂, H₂S, H₂, SO₂, NO, NO₂, N₂, HCs, BrCH₃, SO₂F₂, Ar, He, NH₃, SF₆
Measurement Range0.1 ppm to 100% vol (configurable per gas)
Repeatability±1% FS
Resolution0.1 ppm
Response Time (T₉₀)≤30 s (varies by sensor type)
Zero Drift±2% FS / month
Span Drift±1% FS / month
Linearity Error±2% FS
Output4–20 mA analog, digital display, relay outputs (alarm & fault), remote sampling capable
Power Supply110/220/240 V AC, 50/60 Hz
Power Consumption13 W typical
Enclosure RatingIP54
Operating Temperature0–40 °C
Weight2.7 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADEV
OriginItaly
ModelM860
Measurement PrincipleThermal Conductivity Detection
Gas SpecificitySF₆ in Binary Mixtures (e.g., SF₆/N₂, SF₆/air, SF₆/CF₄)
Range0–100% SF₆ by Volume
Accuracy±0.2% FS (flow-independent)
Response Timet₆₀ = 20 s, t₉₀ = 45 s
Operating Temperature−30 °C to +50 °C (optimal accuracy maintained across full range)
Sample Flow Rate0.2–0.5 L/min
DisplayHigh-contrast LCD, 0.1% SF₆ resolution
Power SupplyRechargeable Li-ion battery (integrated, with overcharge/over-discharge protection) + AC adapter
Dimensions248 × 230 × 98 mm
Weight2.5 kg
Built-in ComponentsPrecision pressure regulator, particulate filter, laminar flow meter
EnclosureRuggedized shock-absorbing transport case compliant with IEC 60068-2-64 for field deployment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADEV
OriginItaly
ModelMODEL 3750
Instrument TypeOnline Fixed-Mount Gas Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption Spectroscopy
Measured GasesCO, CO₂, CH₄, SO₂, NH₃, NO₂, NO
Minimum Range0–20 ppm
Repeatability±1% FS
Resolution0.01%
Response Time (T90)10 s
Zero Drift±1% FS/7 d
Span Drift±2% FS/7 d
Linearity Error±2% FS
Sample Flow Rate500–1000 mL/min
Operating Temperature–5 °C to +45 °C
Output Signal4–20 mA or 0–10 mA DC (configurable)
Warm-up Time30 min
Sample Pressure (Inlet)0.4 MPa
Cell Pressure20 kPa
Contact Rating120 VAC / 1 A, 24 VDC / 1 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADEV
OriginBeijing, China
ModelTMWA680
Treatment Capacity≥200 Nm³/h
Working Pressure≤0.8 MPa
Inlet Argon Purity>99.99% (O₂ ≤15 ppm)
Purified OutputO₂ ≤0.5 ppm, Dew Point ≤−76 °C, Total Carbon ≤0.5 ppm, Particulates ≤3.5 particles/L (≤0.1 µm, Class 100)
Deoxygenation & Drying Regeneration Temp350 °C
Regeneration Duration8 h
Power Consumption28 kW
Voltage/Frequency380 V / 50 Hz
Dimensions (W×L×H)1500×2000×2200 mm
Weight~1200 kg
Valve ActuationBürkert Solenoid Valves (10⁷ cycle lifetime)
Control InterfacePLC with HMI touchscreen, RS-485 & 4–20 mA analog outputs
ComplianceMeets and exceeds GBT 4842–2006 (High-Purity Argon Specification)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-2500
Measurement PrincipleElectrochemical Fuel Cell
Range Options0–1%, 0–5%, 0–10%, 0–25% O₂ by volume (FS)
Accuracy< ±1% of full scale
Resolution0.001% O₂
Response Time (T₉₀)≤10 seconds
LinearityR² > 0.995
Operating Temperature–10°C to +45°C (GPR sensor)
Pressure Range5–30 psig inlet
Flow Rate0.5–5 SCFH (recommended: 2 SCFH)
CompensationAutomatic temperature and barometric pressure compensation
Output Signal4–20 mA analog (isolated)
Enclosure RatingNEMA 4X aluminum housing
Electrical Interface12–28 VDC
Ingress ProtectionIP66
ComplianceCE-marked, ISO 9001 certified, compatible with IS barrier for Class I, Division 1, Groups A–D (per UL 913/IEC 60079-11)
Sensor Lifetime36 months typical (GPR-11-32-4 fuel cell)
Optional SensorXLT-11-24-4 (for CO₂-rich environments >0.5% CO₂)
Calibration Gas Recommendation80% FS O₂ in inert balance
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADEV
OriginItaly
Model8869
Instrument TypeOnline Gas Analyzer
Detection PrincipleNondispersive Infrared (NDIR)
Measured GasCO (single-component configuration)
Range0–5000 ppm
Repeatability±1% FS
Resolution0.1% of full scale
Response Time (T90)≤15 s
Zero Drift≤1% FS/month
Span Drift≤1% FS/month
Linearity Error±1% FS
Temperature & Pressure CompensationYes
Output Signals4–20 mA (isolated), RS-485 (Modbus RTU)
DisplayBacklit LCD
Enclosure RatingATEX II 2G Ex d IIC T6 Gb / CSA Class I, Division 2, Groups A–D
Installation19″ rack-mount, panel-mount, or benchtop
Operating Environment−5 °C to +45 °C, <90% RH (non-condensing)
Sample InletRc¼ or NPT¼
Sample Flow Rate0.25–2 L/min
Sample Pressure±0.5 to ±1.5 bar(g)
Sample Temperature0–50 °C
Sample Humidity<90% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADEV
OriginItaly
ModelG480
Sensor TypeElectrochemical Fuel Cell
Measurement Ranges0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–1% O₂, 0–25% O₂ (auto/manual range switching)
Accuracy±1% of reading
Resolution0.01% O₂ (equivalent to 100 ppb at 1% range)
LinearityR² > 0.995
T₉₀ Response Time≤10 s
Operating Temperature5–45°C (GPR sensor), –20–45°C (XLT sensor)
Sample Pressure5–30 psig inlet, vent to atmosphere
Flow Rate0.5–5 SCFH (recommended: 2 SCFH / ~1 L/min)
Sensitivity Drift<0.5% FS over 30 days
CalibrationCertified standard gas at ≥80% of selected span
CompensationAutomatic pressure & temperature compensation
Outputs4–20 mA (2-wire loop-powered)
Power Supply9–28 V DC (24–28 V DC with intrinsic safety barrier)
EnclosureAnodized aluminum, NEMA 4X rated
Dimensions4" × 9" × 3" (102 × 229 × 76 mm)
Weight1 kg
Wetted MaterialsCorrosion-resistant alloys (316 SS, PTFE, FKM)
CertificationsCE, ISO 9001, ATEX/IECEx compliant (with external safety barrier for Zone 1 / Class I, Div 1, Groups B, C, D)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADEV
OriginItaly
Model6866
Sensor TypeExplosion-Proof Thermal Conductivity Detector (TCD)
MountingDIN Rail
Output4–20 mA (isolated), RS232 (9600 baud, ASCII, RTS/CTS)
MeasurandH₂ in N₂ or Ar (0–10%, 0–30%, 0–100%), He in Ar (0–10%, 0–30%, 0–100%), N₂ in N₂O (75–100%, 0–100%), etc.
Operating Temp−20 °C to +50 °C
Sample Pressure1 bar ±100 mbar (abs. max 10 bar)
Sample Flow100–300 mL/min
Accuracy±1% FS
Repeatability±0.5% FS
Resolution0.1% FS
Power24 VDC ±10%, ≤10 W
EnclosureIP65-rated DIN rail housing (85 × 100 × 35 mm)
CertificationsATEX II 2G EEx d IIB + H₂ T6/T3, EMC Directive 89/336/EEC, Low Voltage Directive 73/23/EEC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-2900
Measurement PrincipleElectrochemical Fuel Cell
Range Options0–1%, 0–5%, 0–10%, 0–25% O₂ by volume (FS)
Accuracy< ±1% FS
Linearity>0.995
Response Time (t₉₀)≤10 seconds
Sensitivity<0.5% FS
Pressure Range (Inlet)5–30 psig (max 100 psig)
Outlet PressureAmbient
Flow Rate1–5 SCFH (recommended: 2 SCFH)
Temperature Range (Sensor)GPR-11-60-4: –10 to +45°C
XLT-11-24-4–20 to +45°C
CompensationAutomatic temperature and barometric pressure compensation
Output Signals0–1 VDC analog + isolated 4–20 mA
Display Resolution0.001% O₂
EnclosureAnodized aluminum panel-mount housing
CertificationsCE, ISO 9001
ComplianceDesigned for general-purpose industrial environments per IEC 61000-6-2/6-4 and EN 61326-1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-1200
Measurement Range0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–1% / 0–25% O₂ (user-selectable)
Accuracy< ±1% of full scale
Detection Limit100 ppb
Sensor TypeElectrochemical (GPR-12-333 or optional XLT-12-333)
Sensor Lifetime24 months at 25°C with average O₂ < 1000 ppm
Response Time (t₉₀)10 seconds
Recovery Time to 10 ppm after air exposure60 min
Operating Temperature5–45°C (GPR sensor), –20–45°C (XLT sensor)
Sample Flow Rate0.25–2.5 L/min (recommended: 1 L/min)
Inlet Pressure5–30 psig
Exhaustambient
Display2.75″ × 1.375″ LCD, 0.01 ppm resolution
EnclosureNEMA 4X, 8.6″ × 9″ × 3″, 12 lbs
PowerRechargeable battery (60 days standby, 1 day with pump active)
Output Signal0–1 V analog
CertificationsCE, ATEX/IECEx certified for intrinsic safety (Class I, Div. 1, Groups A, B, C, D)
Sample Wetted Materials316 stainless steel
Linear Correlation Coefficient>0.995 across all ranges
Temperature & Pressure CompensationYes
Interface1/8″ compression fitting
ControlsRange selector switch, waterproof keypad, calibration/system function keys
Status IndicatorsLED for low battery and charging mode
Optional AccessoriesXLT-12-333 low-temp sensor, integrated sample pump (general-purpose or intrinsically safe), carrying case, inlet particulate filter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-1200
Measurement PrincipleElectrochemical Fuel Cell
Range0–10 / 100 / 1000 ppm, 0–1% / 25% FS
Accuracy<1% FS
Linearity>0.995
Sensitivity<0.5% FS
Response Time (T90)10 s
Recovery Time to 10 ppm60 s
Operating TemperatureGPR Sensor: 5–45°C
XLT Sensor–20–+45°C
Sample Gas CompatibilityInert gases, He, H₂, mixed gases, CO₂-containing acidic gases
Pressure RangeInlet 5–30 psig, Outlet atmospheric
Flow Rate1–5 SCFH (recommended 2 SCFH)
Temperature CompensationBuilt-in
Display Resolution0.01 ppm
Output Signal0–1 VDC
Enclosure RatingNEMA 4X aluminum-coated
Hazardous Area ClassificationClass I, Division 1, Groups A–D
Calibration Gas80% FS O₂ standard gas recommended
PowerRechargeable battery (60-day standby
InterfaceWaterproof membrane keypad, menu-driven configuration
IndicatorsLow-battery LED, charging-mode LED
Optional SensorsXLT-12-333 (for CO₂ >0.5% applications)
Optional AccessoriesIntegral sampling pump (intrinsically safe design), carry case, flow control valve, sample/bypass selector valve, rotameter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADEV
OriginItaly
ModelGY-2000
Measurement RangeCH₄: 0–100% vol, CO₂: 0–50% vol, H₂S: 0–9999 ppm, O₂: 0–20% vol, pH: 0–14, Temperature: 0–100°C, Pressure: 0–100 kPa
Resolution0.01% (for gas vol%), ppm-level detection for H₂S
Response Time≤30 s
Detection PrinciplesNon-dispersive Infrared (NDIR) for CH₄/CO₂, Electrochemical for H₂S/O₂, Potentiometric for pH, RTD/Thermistor for T, Piezoresistive for P
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADEV
OriginItaly
Model886TR
Measurement PrincipleThermal Conductivity Detection (TCD)
H₂ in Air Range75–100% or 85–100%
H₂ in CO₂ Range0–100%
CO₂ in Air Range0–100%
Accuracy±1% FS
Repeatability≤0.3% FS
Linearity Error≤1% FS
Response Time (t₆₀)H₂ <13 s, CO₂ <23 s
Flow Rate100 mL/min – 2 L/min
Sample Connection1/4″ or 6 mm compression fitting
Analog OutputsFour isolated 4–20 mA channels
Digital InterfaceRS232 / RS485
Power Supply24–30 VDC (sensor), or 115 VAC ±10% / 220 VAC ±20%, 50 ±0.5 Hz, 150 VA
Enclosure RatingIP66
Explosion ProtectionATEX II 2G Ex d IIC T6 Gb, CSA Class I, Div 1, Groups A, B, C, D, T6
Hazardous Area ClassificationZone 1 / Zone 2, Class I, Division 1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADEV
OriginItaly
ModelG480EC
Sensor TypeElectrochemical Fuel Cell
Measurement Range0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–1% O₂, 0–25% O₂ (auto/manual range selection)
Accuracy±1% of reading
Resolution0.01% O₂
LinearityR² > 0.995
T₉₀ Response Time≤10 s
Operating Temperature5–45°C (GPR sensor), –20–45°C (XLT sensor)
Sample Pressure5–30 psig inlet, vent to atmosphere
Flow Rate0.5–5 SCFH (recommended: 2 SCFH / ~1 L/min)
Sensitivity Drift<0.5% FS per month
CalibrationCertified standard gas at ~80% of selected span
CompensationAutomatic pressure & temperature compensation
Output4–20 mA (2-wire), optional alarm relay
Power Supply9–28 V DC (24–28 V DC with intrinsic safety barrier)
EnclosureAnodized aluminum, NEMA 4X rated
Dimensions102 × 229 × 76 mm (4" × 9" × 3")
Weight~1 kg
Wetted MaterialsCorrosion-resistant alloys and fluoropolymers
CertificationsCE, ISO 9001, ATEX/IECEx compliant (with external intrinsically safe barrier for Zone 1 / Class I, Div 1, Groups B, C, D)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-1900
Measurement PrincipleElectrochemical Fuel Cell
Range0–10 / 100 / 1000 ppm, 0–1% / 25% FS
Accuracy<1% FS
Sensitivity<0.5% FS
Linearity>0.995
Response Time (T90)10 s
Recovery Time to 10 ppm60 s
Operating Temperature5–45 °C
Operating Pressure (Inlet)5–30 psig (max 100 psig)
Outlet PressureAmbient
Flow Rate1–3 SCFH (recommended 2 SCFH)
CompensationAutomatic temperature and barometric pressure compensation
Output Signals0–1 V analog, isolated 4–20 mA
Alarm OutputsTwo user-adjustable capacitive relay alarms
CalibrationRecommended with 80% FS span gas
DisplayLarge LCD with 0.001 ppm resolution
EnclosureAnodized aluminum panel-mount housing
Power Supply220 VAC, 50/60 Hz
CertificationsCE, ISO 9001
Sensor OptionXLT-12-333 (for CO₂ >0.5% applications)
Communication InterfaceRS-232 serial port
Wetted MaterialsStainless steel
Ingress ProtectionIP65-rated front panel (per enclosure design)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-1600
Measurement PrincipleElectrochemical Fuel Cell
Range0–10 / 100 / 1000 ppm, 0–1% / 25% FS
Accuracy<1% FS
Linearity>0.995
Sensitivity<0.5% FS
Response Time (T90)10 s
Recovery Time to 10 ppm60 s
Operating Temperature5–45 °C
Operating PressureInlet 5–30 psig (max 100 psig), Outlet: Ambient
Flow Rate1–3 SCFH (recommended 2 SCFH)
Display Resolution0.001 ppm
Output Signals0–1 V DC and isolated 4–20 mA
Alarm OutputsTwo user-adjustable capacitive relay alarms
CalibrationRecommended with 80% FS O₂ standard gas
CompensationAutomatic ambient temperature and barometric pressure compensation
Optional AccessoriesXLT-12-333 sensor (for CO₂ >0.5%), 19" rack-mount glass enclosure, NEMA 4/4X wall-mount housing, heated sampling system, flow control valve, sample/bypass selector valve, rotameter
CertificationsCE, ISO 9001