| Brand | ADEV |
|---|---|
| Origin | Beijing, China |
| Model | MODEL3750 |
| Instrument Type | Online Continuous Emission Monitor |
| Detection Principle | Dual-Beam NDIR (Non-Dispersive Infrared) + Electrochemical (EC) + Thermal Conductivity (TCD) + Photoionization (PID) Sensor Modules |
| Measurable Gases | CO, CO₂, CH₄, C₂H₄, C₃H₈, C₄H₁₀, H₂, O₂, NO, NO₂, N₂O, NH₃, SO₂, H₂S, SF₆, Ar, He, BrCH₃, SO₂F₂, HC (hydrocarbons) |
| Range Options | 0–100 ppm to 0–100% vol (user-selectable per channel) |
| Minimum Detectable Range | 0–20 ppm |
| Resolution | 0.1 ppm |
| Repeatability | ±1% FS |
| Zero Drift | ±2% FS / 7 days |
| Span Drift | ±1% FS / 7 days |
| Linearity Error | ±2% FS |
| Response Time (T₉₀) | ≤10 s (for most NDIR channels), ≤30 s (for EC/TCD/PID) |
| Compliance | CE-marked |
| Output Interfaces | 4–20 mA analog (isolated), RS232, RS485, CAN bus |
| Data Logging | Internal non-volatile memory (≥100,000 records), timestamped with real-time clock |
| Display & UI | 320×240 monochrome LCD, full Chinese menu, five-key navigation |
| Enclosure | 19-inch rack-mount chassis (4U height), IP20 rated |
| Power Supply | 220 VAC ±10%, 50/60 Hz |
| Operating Temperature | 5–40 °C |
| Humidity Range | 20–80% RH (non-condensing) |
| Brand | ADEV |
|---|---|
| Origin | Beijing, China |
| Model | FY-1000 |
| Instrument Type | Fixed-mount online analyzer |
| Detection Targets | O₂, CH₄, CO, CO₂, H₂S, H₂, SO₂, NO, NO₂, N₂, HCs, BrCH₃, SO₂F₂, Ar, He, NH₃, SF₆ |
| Measurement Range | 0.1 ppm to 100% vol (configurable per gas) |
| Repeatability | ±1% FS |
| Resolution | 0.1 ppm |
| Response Time (T₉₀) | ≤30 s (varies by sensor type) |
| Zero Drift | ±2% FS / month |
| Span Drift | ±1% FS / month |
| Linearity Error | ±2% FS |
| Output | 4–20 mA analog, digital display, relay outputs (alarm & fault), remote sampling capable |
| Power Supply | 110/220/240 V AC, 50/60 Hz |
| Power Consumption | 13 W typical |
| Enclosure Rating | IP54 |
| Operating Temperature | 0–40 °C |
| Weight | 2.7 kg |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | MODEL 3750 |
| Instrument Type | Online Fixed-Mount Gas Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption Spectroscopy |
| Measured Gases | CO, CO₂, CH₄, SO₂, NH₃, NO₂, NO |
| Minimum Range | 0–20 ppm |
| Repeatability | ±1% FS |
| Resolution | 0.01% |
| Response Time (T90) | 10 s |
| Zero Drift | ±1% FS/7 d |
| Span Drift | ±2% FS/7 d |
| Linearity Error | ±2% FS |
| Sample Flow Rate | 500–1000 mL/min |
| Operating Temperature | –5 °C to +45 °C |
| Output Signal | 4–20 mA or 0–10 mA DC (configurable) |
| Warm-up Time | 30 min |
| Sample Pressure (Inlet) | 0.4 MPa |
| Cell Pressure | 20 kPa |
| Contact Rating | 120 VAC / 1 A, 24 VDC / 1 A |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | 8869 |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Nondispersive Infrared (NDIR) |
| Measured Gas | CO (single-component configuration) |
| Range | 0–5000 ppm |
| Repeatability | ±1% FS |
| Resolution | 0.1% of full scale |
| Response Time (T90) | ≤15 s |
| Zero Drift | ≤1% FS/month |
| Span Drift | ≤1% FS/month |
| Linearity Error | ±1% FS |
| Temperature & Pressure Compensation | Yes |
| Output Signals | 4–20 mA (isolated), RS-485 (Modbus RTU) |
| Display | Backlit LCD |
| Enclosure Rating | ATEX II 2G Ex d IIC T6 Gb / CSA Class I, Division 2, Groups A–D |
| Installation | 19″ rack-mount, panel-mount, or benchtop |
| Operating Environment | −5 °C to +45 °C, <90% RH (non-condensing) |
| Sample Inlet | Rc¼ or NPT¼ |
| Sample Flow Rate | 0.25–2 L/min |
| Sample Pressure | ±0.5 to ±1.5 bar(g) |
| Sample Temperature | 0–50 °C |
| Sample Humidity | <90% RH |