Empowering Scientific Discovery

Beijing Haiguang Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelHGLF
Instrument TypeHyphenated LC-AFS System
Sample IntroductionDual Sequential Injection Pumps
Waste DisposalGravity-Driven Static Drainage
Sample Introduction ModeVapor Generation / Hydride Generation
Gas Flow ControlDigital Mass Flow Controllers
Detectable ElementsAs, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au
Relative Standard Deviation (RSD)< 0.6%
Linear Dynamic Range> 3 orders of magnitude
Detection Limits (As, Se, Pb, Bi, Sb, Te, Sn)< 0.01 µg/L
Photomultiplier Tube Wavelength Range160–320 nm
Atomizer Temperature Control Range50–450 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
ModelHGA-E30
Instrument TypeFlame and Graphite Furnace AAS
Optical DesignCzerny-Turner with 270 mm focal length and 1800 lines/mm grating
Slit Widths6 auto-switchable positions
Light Source8-lamp rotating turret with simultaneous preheating
Lamp RecognitionAutomatic identification of hollow cathode lamps (HCL), self-reversal lamps, and high-performance lamps
Background CorrectionD₂ lamp and self-absorption methods across full wavelength range (190–900 nm)
Atomization ModesFlame (triple-gas flow control with safety interlock) and electrothermal graphite furnace (integrated power supply)
Autosampler84-position sliding-type flame/graphite furnace integrated autosampler
Software FunctionsAuto-alignment, auto-peak search, auto-slit selection, startup diagnostics, and analytical condition recommendation
Optional AccessoriesHydride generation system for As, Hg, Se, Sb, Bi, etc.
ComplianceFully supports GB, HJ, and ISO 8288, ISO 11170, ASTM D5059, USP <730>, FDA 21 CFR Part 11 (audit trail enabled)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
ModelHGM-200
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleCold Vapor Atomic Absorption Spectrometry (CVAAS)
Detection Limit≤0.005 ng
Measurement Range0–15 ng (long-path absorption cell), 15–200 ng (short-path absorption cell)
Sample Throughput2.5 min per sample
Sample Capacity60-position autosampler tray
ComplianceASTM D7623, EPA Method 7473, GB 5009.17-2021, HJ 923-2017, HJ 910-2017, SN/T series, ISO/IEC 17025-aligned operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic (China-made)
ModelAFS-9560
Price RangeUSD 56,000 – 70,000 (FOB Beijing)
Instrument TypeMulti-channel Atomic Fluorescence Spectrometer
Sample IntroductionDual Sequential Injection Pump
Detectable ElementsAs, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au
RSD<1.0% (for As at 1 µg/L, n=11)
Linear Dynamic Range>3 orders of magnitude (typical for hydride-generating elements)
Detection LimitsSub-pg/mL level (e.g., As: 0.01 ng/L
Hg0.001 ng/L
Se0.03 ng/L, per ISO 17294-2 and GB/T 223.74–2021)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHGF-V9
Instrument TypeMulti-channel Atomic Fluorescence Spectrometer
Sample IntroductionDual Sequential Injection Pump
Waste DisposalGravity-driven (Static) Drainage
Hydride Generation ModeVapor Generation / Hydride Generation
Gas Flow ControlMass Flow Controllers (MFCs)
Detectable ElementsAs, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au
Relative Standard Deviation (RSD)< 0.6%
Linear Dynamic Range> 3 orders of magnitude
Detection Limits (As, Se, Pb, Bi, Sb, Te, Sn)< 0.01 µg/L
Photomultiplier Tube Wavelength Range160–320 nm
Atomizer Temperature Control Range50–450 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelAFS-9530
Price RangeUSD 42,000 – 56,000
Instrument TypeSingle-Channel Atomic Fluorescence Spectrometer
Sample IntroductionDual Sequential Injection Pumps
Detectable ElementsAs, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au
RSD<1.0% (typical for As at 1 µg/L)
Linear Dynamic Range>3 orders of magnitude
Detection Limits (3σ)As, Hg, Se < 0.01 µg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
ModelHGF-V2
Instrument TypeMulti-channel Atomic Fluorescence Spectrometer
Sample IntroductionDual Sequential Injection Pump
Waste DisposalGravity-based
Sample Introduction ModeVapor Generation / Hydride Generation
Gas Flow ControlMass Flow Controller (MFC)
Detectable ElementsAs, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au
Relative Standard Deviation (RSD)< 0.6%
Linear Dynamic Range> 3 orders of magnitude
Detection Limits (As, Se, Pb, Bi, Sb, Te, Sn)< 0.01 µg/L
Photomultiplier Tube Wavelength Range160–320 nm
Atomizer Temperature Control Range50–450 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
ModelAFS-8900
Instrument TypeMulti-channel Atomic Fluorescence Spectrometer
Sample IntroductionPeristaltic Pump
Detectable ElementsAs, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au
Detection ModeHydride Generation – Cold Vapor Atomic Fluorescence Spectrometry (HG-CV-AFS)
Automation FeaturesOnboard Calibration Curve Generation, Auto-dilution, Full Measurement Automation
Lamp SystemHigh-Performance Encoded Hollow Cathode Lamps with Lifetime Monitoring
AtomizerShielded Low-Temperature Quartz Furnace Atomizer
Gas-Liquid SeparatorSealed Two-Stage Separation Unit
Gas ControlArray-Structured Argon Flow System with Flow Optimization Module
Software PlatformWindows 7/8/10/XP Compatible AFS Control Suite with Audit Trail & Data Export to Excel
Compliance ReadyDesigned for GLP/GMP environments
Upgrade Interfaces预留形态分析、Hg/Cd电热蒸发接口
Safety & DiagnosticsReal-time Argon-Hydrogen Flame Monitoring Window, Power Isolation Architecture, Self-Check & Fault Alert Protocol
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
ModelHGF-V4
Instrument TypeMulti-channel Atomic Fluorescence Spectrometer
Sample IntroductionDual Sequential Injection Pump
Waste DisposalGravity-driven (Static) Drainage
Sample Introduction ModeVapor Generation / Hydride Generation
Gas Flow ControlMass Flow Controllers (MFCs)
Detectable ElementsAs, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au
Relative Standard Deviation (RSD)< 0.6%
Linear Dynamic Range> 3 orders of magnitude
Detection Limits (As, Se, Pb, Bi, Sb, Te, Sn)< 0.01 µg/L
PMT Wavelength Range160–320 nm
Atomizer Temperature Control Range50–450 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAFS-9600
Price RangeUSD 42,000 – 56,000
Instrument TypeSingle-Channel Atomic Fluorescence Spectrometer
Sample IntroductionPeristaltic Pump
Detectable ElementsAs, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au
RSD<1.0% (for As at 1 µg/L)
Linear Dynamic Range>3 orders of magnitude
Detection LimitsSub-pg/mL level for As, Hg, Se (e.g., As ≤ 0.01 µg/L, Hg ≤ 0.001 µg/L, Se ≤ 0.03 µg/L)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
ModelHGA-E50
Instrument TypeFlame–Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionDeuterium Lamp
Safety FeaturesOver-Temperature Alarm, Low Gas Pressure Alert, Graphite Tube Break/Loose Clamp Detection
Automated FunctionsSelf-Check at Startup, Automatic Slit Adjustment, Peak Search, Lamp Positioning
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
ModelHGCF-200 / HGCF-210
Instrument TypeLaboratory Water Quality Analyzer
Detection ParametersTotal Cyanide, Free Cyanide, Volatile Phenol, Anionic Detergents, Ammonia Nitrogen (NH₃-N), Orthophosphate, Total Phosphorus, Total Nitrogen, Sulfide, Hexavalent Chromium (Cr⁶⁺), Nitrate, Nitrite, Permanganate Index (CODₘₙ), Urea
Compliance StandardsHJ 665–2013, HJ 670–2013, HJ 667–2013, CJT 141–2018, SL/T 788–2019, NY/T 1121.7–2014, NY/T 1228–2015, ISO 14403:2012, ISO 14402:1999, ISO 23913:2016, ISO 15681-2:2003
Optical DetectionDual-beam silicon photodetector or full-spectrum CCD detector
Flow Cell Pathlength Options10 mm to 200 mm
Reaction Coil2 mm i.d. quartz mixing coil
Sample IntroductionAutomated sampler with carbon fiber or borosilicate glass probe, auto-cleaning and wash solution auto-replacement
Online PretreatmentIntegrated heating, digestion, distillation, dialysis, extraction, degassing, dilution, and mixing modules
Light SourceLow-power LED with short stabilization time and >10,000 h lifetime
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelHGCF-100 for Ammonia Nitrogen
Price RangeUSD 28,000 – 35,000
Instrument TypeLaboratory Benchtop
Measurement PrincipleAir-Segmented Continuous Flow Analysis (CFA) with Distillation and Colorimetric Detection
Measurement Range0.01–5 mg/L NH₃–N
Accuracy±1% of reading
Detection Limit≤0.005 mg/L NH₃–N
Sample Throughput30 samples/hour
Batch CapacityUnlimited (software-controlled queue)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
ModelHGCF-200 Ammonia Nitrogen
Measurement PrincipleColorimetric Flow Analysis (Salicylate Method)
Measurement Range0.01–5 mg/L NH₃–N
Detection Limit≤0.005 mg/L NH₃–N
Accuracy±1% of reading
Sample Throughput30 samples/hour
Batch CapacityUnlimited
Optical Cell MaterialFused quartz
Light SourceLow-power LED
DetectorFull-spectrum CCD with built-in monochromator
Online Dilution Ratio1–5000×
Reaction Tubing ID≥2 mm
ComplianceHJ 665-2013, HJ 670-2013, HJ 667-2013, ISO 14403:2012, ISO 14402:1999, ISO 23913:2016, ISO 15681-2:2003
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginHebei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHGFI-10
Product CategoryFlow Injection Analyzer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
ModelGGX-810
Instrument TypeFlame AAS
MonochromatorPlane grating (1800 lines/mm)
Optical SystemSingle-beam
DetectorPhotomultiplier tube (PMT)
Background CorrectionDeuterium lamp (D₂) method
Burner HeadTitanium alloy
Atomization SystemFull-plastic nebulizer chamber + high-efficiency glass concentric nebulizer
Safety FeaturesWater seal detection, waste liquid level monitoring, gas pressure monitoring, flame sensor, automatic gas cutoff on flameout, anti-flashback protection
Graphite Furnace OptionLongitudinal heating
Temp. rangeambient to 3000 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
ModelLC-AFS9530
Instrument TypeMulti-channel Atomic Fluorescence Spectrometer
Sample IntroductionDual Sequential Injection Pumps
Detectable Elements (Speciation)As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au
Speciation CapabilitiesInorganic/organic As (e.g., As(III), As(V), MMA, DMA), Hg species (e.g., Hg²⁺, MeHg⁺, EtHg⁺), Se species (e.g., Se(IV), Se(VI), SeMet, SeCys)
UV Digestion ModeOn-line, switchable between UV and non-UV pathways
Chromatographic ModesIsocratic and gradient elution
Column Temperature ControlIntegrated, programmable (ambient to 80 °C)
Dual Lamp HolderSupports simultaneous pre-heating of two hollow cathode lamps
Software ControlUnified workstation for LC module, UV digestion, hydride generation, AFS detection, and data processing
Automation CompatibilityCompatible with third-party HPLC autosamplers for unattended operation
Arsenic(V) Analysis Time (Isocratic)<7 min
Column Equilibration OptimizationReduced solvent consumption and column stress during method re-equilibration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
ModelLC-AFS6000
Instrument TypeLC–AFS Hyphenated System
Sample IntroductionPeristaltic Pump & Syringe Pump (Dual Mode)
Detectable Elements (Total Analysis)As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au
Detectable Elements (Speciation)As, Hg, Se, Sb (and associated species, e.g., As(III), As(V), MMA, DMA, iAs, MeHg, EtHg, SeCys, SeMet)
Patented Gas–Liquid SeparationZL 201820830427.8
Patented LC–AFS Switching ModuleZL 201420280550.9
Software PlatformWindows 7/8/XP Compatible
Data ExportNative Excel (.xlsx) Integration
Automation InterfaceStandard RS-232/USB for LC Autosampler Coupling
Flame MonitoringIntegrated Argon–Hydrogen Flame Viewing Window
Electrical ArchitectureSegregated High/Low Voltage Design with Modular PCB Layout
Compliance SupportASTM D5762, ISO 17294-2, USP <232>/<233>, EPA Method 1638, GB/T 22105.1–2008
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
ModelGGX-610
Instrument TypeFlame AAS
MonochromatorConcave Grating
Optical SystemSingle-beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionDeuterium Lamp
Spectral Bandwidth0.2 / 0.4 / 1.0 / 2.0 nm (motorized switching)
Wavelength Range190–900 nm
Flame Emission CapabilityYes (for K, Na, Li)
Safety FeaturesAutomatic gas cutoff, flame failure interlock, flashback arrestor
Housing MaterialCorrosion-resistant all-plastic enclosure
Software PlatformWindows 7/8/XP-compatible proprietary AAS control and data analysis suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
Instrument TypeLaboratory Benchtop CFA
ApplicationTotal and Free Cyanide Determination in Water and Environmental Matrices
ComplianceASTM D7511, ISO 14403:2012, HJ 484–2009, EPA Method 335.4
Detection PrincipleSegmented Flow Analysis (SFA) with Air Segmentation, On-line Distillation & UV Digestion
Optical SystemLED-based Photometer with Quartz Flow Cell and Full-spectrum CCD Detector
Sample ThroughputUp to 60 samples/hour
Detection Limit≤0.2 µg/L CN⁻ (as applicable per ISO 14403)
Linear Dynamic Range0–1000 µg/L (adjustable via on-line dilution 1:1 to 1:5000)
Reagent ManagementIntegrated Smart Reagent Rack with Level Sensing & Leak Detection
AutomationFully Automated Sample Introduction, Pre-treatment, Reaction, Separation, Detection & Data Reporting
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic (China-made)
ModelHGF-V3
Instrument TypeMulti-channel Atomic Fluorescence Spectrometer
Sample IntroductionDual Sequential Injection Pump
Waste Liquid DisposalGravity-driven (Static)
Sample Introduction ModeVapor Generation / Hydride Generation
Gas Flow ControlMass Flow Controllers (MFCs)
Detectable ElementsAs, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au
Relative Standard Deviation (RSD)< 0.6%
Linear Dynamic Range> 3 orders of magnitude
Detection LimitsAs, Se, Pb, Bi, Sb, Te, Sn < 0.01 µg/L
Photomultiplier Tube Wavelength Range160–320 nm
Atomizer Temperature Control Range50–450 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
ModelAFS-9710
Instrument TypeMulti-channel Atomic Fluorescence Spectrometer
Sample IntroductionSequential Injection Pump
Detectable ElementsAs, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au
Sample Tray Capacity69 × 25 mL / 134 × 15 mL / 183 × 10 mL coordinate-style autosampler
Valving TechnologyClamp-tube valve (≥500,000 cycles lifetime)
AtomizerShielded low-temperature quartz furnace atomizer
Gas–Liquid SeparatorClosed-loop dual-stage cyclonic separator
Lamp SystemEncoded hollow-cathode lamps with auto-identification and life monitoring
Gas ControlArray-structured argon flow system with intelligent gas-saving module
Software PlatformWindows XP/7/8/10 compatible
Compliance FeaturesBuilt-in self-diagnostic routines, real-time flame status monitoring via observation window, GLP/GMP-ready audit trail logging (via optional software module), 21 CFR Part 11 compliance achievable with validated configuration
Upgrade OptionsLC-AFS hyphenation interface for elemental speciation (e.g., As(III)/As(V), methylmercury), electrothermal evaporation (ETV) modules for Hg/Cd, automated dilution and calibration curve generation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelLC-AFS9560
Price RangeUSD 70,000 – 85,000
Instrument TypeHyphenated LC-AFS System
Sample IntroductionDual Sequential Injection Pumps
Detectable Elements (Speciation & Total)As, Hg, Se, Pb, Ge, Sn, Sb, Bi, Cd, Te, Zn, Au
Regulatory ComplianceFully aligned with GB 5009.11–2023 (inorganic arsenic), GB 5009.17–2023 (methylmercury), and ISO/IEC 17025 method validation requirements
Software ArchitectureIntegrated workstation with GLP-compliant audit trail, electronic signature support per FDA 21 CFR Part 11
Hardware IntegrationModular LC unit with integrated UV post-column digestion, column oven, six-port injection valve, hydride/vapor generation, and dual-stage membrane-based gas–liquid separation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaiguang Instruments
OriginBeijing, China
ModelHGE-300
Extraction TypeSolid-Liquid Extraction
Sample CapacityUp to 24 Positions
Solvent HandlingAutomated Switching, Blending, and Proportional Mixing of Up to 4 Solvents
Sealing MaterialTFM (Perfluoroalkoxy) Gaskets
Safety FeaturesIntegrated Pneumatic Circuit Protection Against Solvent Corrosion and Backflow
Compliance ContextDesigned for GLP-compliant laboratories
Show next