- All
- Favorite
- Popular
- Most rated
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HGLF |
| Instrument Type | Hyphenated LC-AFS System |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Gravity-Driven Static Drainage |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Digital Mass Flow Controllers |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits (As, Se, Pb, Bi, Sb, Te, Sn) | < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 50–450 °C |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGA-E30 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical Design | Czerny-Turner with 270 mm focal length and 1800 lines/mm grating |
| Slit Widths | 6 auto-switchable positions |
| Light Source | 8-lamp rotating turret with simultaneous preheating |
| Lamp Recognition | Automatic identification of hollow cathode lamps (HCL), self-reversal lamps, and high-performance lamps |
| Background Correction | D₂ lamp and self-absorption methods across full wavelength range (190–900 nm) |
| Atomization Modes | Flame (triple-gas flow control with safety interlock) and electrothermal graphite furnace (integrated power supply) |
| Autosampler | 84-position sliding-type flame/graphite furnace integrated autosampler |
| Software Functions | Auto-alignment, auto-peak search, auto-slit selection, startup diagnostics, and analytical condition recommendation |
| Optional Accessories | Hydride generation system for As, Hg, Se, Sb, Bi, etc. |
| Compliance | Fully supports GB, HJ, and ISO 8288, ISO 11170, ASTM D5059, USP <730>, FDA 21 CFR Part 11 (audit trail enabled) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGM-200 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | ≤0.005 ng |
| Measurement Range | 0–15 ng (long-path absorption cell), 15–200 ng (short-path absorption cell) |
| Sample Throughput | 2.5 min per sample |
| Sample Capacity | 60-position autosampler tray |
| Compliance | ASTM D7623, EPA Method 7473, GB 5009.17-2021, HJ 923-2017, HJ 910-2017, SN/T series, ISO/IEC 17025-aligned operation |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-made) |
| Model | AFS-9560 |
| Price Range | USD 56,000 – 70,000 (FOB Beijing) |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| RSD | <1.0% (for As at 1 µg/L, n=11) |
| Linear Dynamic Range | >3 orders of magnitude (typical for hydride-generating elements) |
| Detection Limits | Sub-pg/mL level (e.g., As: 0.01 ng/L |
| Hg | 0.001 ng/L |
| Se | 0.03 ng/L, per ISO 17294-2 and GB/T 223.74–2021) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HGF-V9 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Gravity-driven (Static) Drainage |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controllers (MFCs) |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits (As, Se, Pb, Bi, Sb, Te, Sn) | < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 50–450 °C |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AFS-9530 |
| Price Range | USD 42,000 – 56,000 |
| Instrument Type | Single-Channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| RSD | <1.0% (typical for As at 1 µg/L) |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits (3σ) | As, Hg, Se < 0.01 µg/L |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGF-V2 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Gravity-based |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits (As, Se, Pb, Bi, Sb, Te, Sn) | < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 50–450 °C |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | AFS-8900 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Peristaltic Pump |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| Detection Mode | Hydride Generation – Cold Vapor Atomic Fluorescence Spectrometry (HG-CV-AFS) |
| Automation Features | Onboard Calibration Curve Generation, Auto-dilution, Full Measurement Automation |
| Lamp System | High-Performance Encoded Hollow Cathode Lamps with Lifetime Monitoring |
| Atomizer | Shielded Low-Temperature Quartz Furnace Atomizer |
| Gas-Liquid Separator | Sealed Two-Stage Separation Unit |
| Gas Control | Array-Structured Argon Flow System with Flow Optimization Module |
| Software Platform | Windows 7/8/10/XP Compatible AFS Control Suite with Audit Trail & Data Export to Excel |
| Compliance Ready | Designed for GLP/GMP environments |
| Upgrade Interfaces | 预留形态分析、Hg/Cd电热蒸发接口 |
| Safety & Diagnostics | Real-time Argon-Hydrogen Flame Monitoring Window, Power Isolation Architecture, Self-Check & Fault Alert Protocol |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGF-V4 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Gravity-driven (Static) Drainage |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controllers (MFCs) |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits (As, Se, Pb, Bi, Sb, Te, Sn) | < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 50–450 °C |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AFS-9600 |
| Price Range | USD 42,000 – 56,000 |
| Instrument Type | Single-Channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Peristaltic Pump |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au |
| RSD | <1.0% (for As at 1 µg/L) |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | Sub-pg/mL level for As, Hg, Se (e.g., As ≤ 0.01 µg/L, Hg ≤ 0.001 µg/L, Se ≤ 0.03 µg/L) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGA-E50 |
| Instrument Type | Flame–Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Safety Features | Over-Temperature Alarm, Low Gas Pressure Alert, Graphite Tube Break/Loose Clamp Detection |
| Automated Functions | Self-Check at Startup, Automatic Slit Adjustment, Peak Search, Lamp Positioning |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HGFI-10 |
| Product Category | Flow Injection Analyzer |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | GGX-810 |
| Instrument Type | Flame AAS |
| Monochromator | Plane grating (1800 lines/mm) |
| Optical System | Single-beam |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | Deuterium lamp (D₂) method |
| Burner Head | Titanium alloy |
| Atomization System | Full-plastic nebulizer chamber + high-efficiency glass concentric nebulizer |
| Safety Features | Water seal detection, waste liquid level monitoring, gas pressure monitoring, flame sensor, automatic gas cutoff on flameout, anti-flashback protection |
| Graphite Furnace Option | Longitudinal heating |
| Temp. range | ambient to 3000 °C |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | LC-AFS9530 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Detectable Elements (Speciation) | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| Speciation Capabilities | Inorganic/organic As (e.g., As(III), As(V), MMA, DMA), Hg species (e.g., Hg²⁺, MeHg⁺, EtHg⁺), Se species (e.g., Se(IV), Se(VI), SeMet, SeCys) |
| UV Digestion Mode | On-line, switchable between UV and non-UV pathways |
| Chromatographic Modes | Isocratic and gradient elution |
| Column Temperature Control | Integrated, programmable (ambient to 80 °C) |
| Dual Lamp Holder | Supports simultaneous pre-heating of two hollow cathode lamps |
| Software Control | Unified workstation for LC module, UV digestion, hydride generation, AFS detection, and data processing |
| Automation Compatibility | Compatible with third-party HPLC autosamplers for unattended operation |
| Arsenic(V) Analysis Time (Isocratic) | <7 min |
| Column Equilibration Optimization | Reduced solvent consumption and column stress during method re-equilibration |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | LC-AFS6000 |
| Instrument Type | LC–AFS Hyphenated System |
| Sample Introduction | Peristaltic Pump & Syringe Pump (Dual Mode) |
| Detectable Elements (Total Analysis) | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| Detectable Elements (Speciation) | As, Hg, Se, Sb (and associated species, e.g., As(III), As(V), MMA, DMA, iAs, MeHg, EtHg, SeCys, SeMet) |
| Patented Gas–Liquid Separation | ZL 201820830427.8 |
| Patented LC–AFS Switching Module | ZL 201420280550.9 |
| Software Platform | Windows 7/8/XP Compatible |
| Data Export | Native Excel (.xlsx) Integration |
| Automation Interface | Standard RS-232/USB for LC Autosampler Coupling |
| Flame Monitoring | Integrated Argon–Hydrogen Flame Viewing Window |
| Electrical Architecture | Segregated High/Low Voltage Design with Modular PCB Layout |
| Compliance Support | ASTM D5762, ISO 17294-2, USP <232>/<233>, EPA Method 1638, GB/T 22105.1–2008 |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | GGX-610 |
| Instrument Type | Flame AAS |
| Monochromator | Concave Grating |
| Optical System | Single-beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Spectral Bandwidth | 0.2 / 0.4 / 1.0 / 2.0 nm (motorized switching) |
| Wavelength Range | 190–900 nm |
| Flame Emission Capability | Yes (for K, Na, Li) |
| Safety Features | Automatic gas cutoff, flame failure interlock, flashback arrestor |
| Housing Material | Corrosion-resistant all-plastic enclosure |
| Software Platform | Windows 7/8/XP-compatible proprietary AAS control and data analysis suite |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-made) |
| Model | HGF-V3 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Liquid Disposal | Gravity-driven (Static) |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controllers (MFCs) |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Se, Pb, Bi, Sb, Te, Sn < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 50–450 °C |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | AFS-9710 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Sequential Injection Pump |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| Sample Tray Capacity | 69 × 25 mL / 134 × 15 mL / 183 × 10 mL coordinate-style autosampler |
| Valving Technology | Clamp-tube valve (≥500,000 cycles lifetime) |
| Atomizer | Shielded low-temperature quartz furnace atomizer |
| Gas–Liquid Separator | Closed-loop dual-stage cyclonic separator |
| Lamp System | Encoded hollow-cathode lamps with auto-identification and life monitoring |
| Gas Control | Array-structured argon flow system with intelligent gas-saving module |
| Software Platform | Windows XP/7/8/10 compatible |
| Compliance Features | Built-in self-diagnostic routines, real-time flame status monitoring via observation window, GLP/GMP-ready audit trail logging (via optional software module), 21 CFR Part 11 compliance achievable with validated configuration |
| Upgrade Options | LC-AFS hyphenation interface for elemental speciation (e.g., As(III)/As(V), methylmercury), electrothermal evaporation (ETV) modules for Hg/Cd, automated dilution and calibration curve generation |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | LC-AFS9560 |
| Price Range | USD 70,000 – 85,000 |
| Instrument Type | Hyphenated LC-AFS System |
| Sample Introduction | Dual Sequential Injection Pumps |
| Detectable Elements (Speciation & Total) | As, Hg, Se, Pb, Ge, Sn, Sb, Bi, Cd, Te, Zn, Au |
| Regulatory Compliance | Fully aligned with GB 5009.11–2023 (inorganic arsenic), GB 5009.17–2023 (methylmercury), and ISO/IEC 17025 method validation requirements |
| Software Architecture | Integrated workstation with GLP-compliant audit trail, electronic signature support per FDA 21 CFR Part 11 |
| Hardware Integration | Modular LC unit with integrated UV post-column digestion, column oven, six-port injection valve, hydride/vapor generation, and dual-stage membrane-based gas–liquid separation |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | GGX-900 |
| Instrument Type | Flame AAS |
| Monochromator | Concave Grating |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Spectral Bandwidth | 0.2 / 0.4 / 1.0 / 2.0 nm (motorized switching) |
| Wavelength Range | 190–900 nm |
| Flame Atomization System | Titanium Alloy Burner, Corrosion-Resistant Hybrid Nebulizer Chamber, High-Efficiency Glass Concentric Nebulizer with Impact Bead |
| Safety Features | Gas/Air Interlock, Automatic Flame-Out Cutoff, Over-Temperature Alarm for Magnet Assembly, Water-Cooled Permanent Magnet |
| Software Platform | Windows 7/8/XP Compatible AAS Control & Data Analysis Suite with ASTM/ISO/GLP-Compliant Audit Trail, Excel Export, Multi-Mode Quantitation (Absorption, Background-Subtracted Absorption, Pure Background, Emission) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | GGX-830 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane grating (1800 lines/mm) |
| Optical System | Single-beam |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | Deuterium (D₂) lamp |
| Burner Head | Titanium alloy |
| Graphite Furnace | Longitudinal heating, temperature range: ambient to 3000 °C, temperature control accuracy ≤0.5% at 2000 °C, ramp rate ≥2000 °C/s |
| Autosampler | 52-position graphite furnace autosampler with automated calibration curve generation, matrix modifier addition capability, and sample delivery precision ≤±0.5% |
| Safety Systems | Flame monitoring, gas pressure sensing, water seal detection, waste liquid level detection, anti-flashback protection, automatic fuel cutoff upon flameout |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGA-100 |
| Instrument Type | Online Mercury Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Sample Introduction | Solid/Liquid/Gas Direct Injection |
| Analysis Time | <5 min per sample |
| Sample Capacity | 40-position Autosampler |
| Reagent Consumption | Zero chemical reagents required |
| Temperature-Controlled Flow Path | Yes |
| Gold Amalgamation Trap | Nano-coated Au-Hg trap integrated |
| Catalyst System | Dual-stage composite catalyst |
| Exhaust Treatment | Integrated catalytic oxidation + activated carbon adsorption |
| Compliance Framework | Designed for GLP-compliant laboratories |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | LC-AFS6500 |
| Instrument Type | LC–AFS Hyphenated System |
| Sample Introduction | Sequential Injection Pump |
| Target Elements (Total Analysis) | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| Target Elements (Speciation) | As, Hg, Se, Sb |
| UV Digestion Unit | Integrated, Dual-mode (UV/Non-UV), Auto-switching Valve Control |
| LC Pump | Imported German Knauer Micro High-Pressure Binary Gradient Pump |
| Autosampler Capacity | 183-position Rotating Tray |
| Atomizer | Shielded Quartz Furnace with Ar–H₂ Flame |
| Gas Control | Intelligent Pneumatic System with Self-diagnosis & Flow Regulation |
| Exhaust Treatment | Integrated Activated Carbon Trap |
| Software | Windows-compatible Control Suite with Bidirectional LC & AFS Instrument Control, CFR Part 11–Ready Audit Trail, Excel Export, and Chromatographic Data Integration |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HGCF-200 |
| Price Range | USD 70,000 – 100,000 (FOB China) |
| Instrument Type | Continuous Flow Analyzer (CFA) |
| Detection Principle | Segmented Flow Spectrophotometry with Air Segmentation |
| Optical Detection Options | Full-spectrum CCD detector or high-sensitivity dual-beam silicon photodiode detector |
| Flow Cell Pathlength Options | 10 mm to 200 mm |
| Reaction Coil Material | Fused silica (2 mm inner diameter) |
| Integrated Sample Pretreatment | On-line digestion, distillation (steam distillation/blow-out), dialysis, extraction, heating, mixing, dilution, degassing, and auto-cleaning |
| Compliance Standards | ASTM D3869, ISO 14402, ISO 14403, ISO 23913, ISO 15681-2, HJ 665–667, HJ 670, CJJ/T 141, SL/T 788, NY/T 1121.7, NY/T 1228 |
Show next