Empowering Scientific Discovery

Beijing Hangfeng Kewei Equipment Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelKLD-Z-X
Detection ParameterParticulate Contamination (Solid Particle Count)
Flow Range50–300 mL/min
Weight538 g (with display)
Power SupplyDC 12–24 V (ripple <30 mVp-p)
Dimensions94 × 87 × 46 mm
Operating Temperature−20 °C to +60 °C
Media Temperature−20 °C to +80 °C
Pressure Range3–30 MPa (high-pressure channel) / 0.3–3 MPa (low-pressure channel)
Humidity20–85% RH (operating, non-condensing)
Communication InterfaceRS485 / RS232
Repeatability±0.5 ISO contamination code
Channel Configuration4-channel or 6-channel (field-configurable)
Thread SpecificationM10×1 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (PRC)
ModelFYH-M
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
ModelOCI-1
Spectral Range203–800 nm
Sample Volume~2 mL
Detection Limit1 ppm (for key wear metals)
Operating Temperature0–50 °C
Relative Humidity0–90% RH (non-condensing)
Power Consumption10 W (standby), 500 W (during spark excitation)
Voltage220 V / 50 Hz
Dimensions (L×W×H)737 × 686 × 830 mm
Weight<68 kg
Data InterfaceUSB + Ethernet
Compliant StandardsASTM D6595, ASTM D6596 (lubricants), ASTM D6728 (fuels)
Analyte ElementsFe, Al, Cu, Cr, Ni, Ca, Mn, Mo, Ti, Cd, Pb, Sn, Na, Ag (expandable per customer requirement)
DetectorCCD array
Excitation MethodRotating disk electrode (RDE) with controlled spark discharge
Sample PrepMinimal — no acid digestion or dilution required
Analysis Time≤30 seconds per sample
Integrated ComponentsIndustrial-grade embedded PC, thermal printer, intelligent temperature stabilization system
OptionalVibration-damping transport case, Expert Diagnostic Module (EDM), electrode maintenance kit (grinding blade, cleaning wipes, calibration oils, sample cups, RDE rods & disks)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
ModelKLD-O-S
Product TypeOnline Analyzer
Detection ParametersParticle Contamination & Water Content (Relative Humidity)
Compliance StandardsISO 4406, GJB 420B, NAS 1638
Flow Rate50–120 mL/min
Power SupplyDC 10–26 V (Ripple < 100 mVp-p)
Dimensions105 × 89 × 64 mm
Weight538 g
Operating Temperature−20 to +60 °C
Storage Temperature−20 to +80 °C
Pressure Rating< 1 MPa
Humidity Range (Operating)20–85% RH (non-condensing)
(Storage)up to 98% RH
Communication InterfaceRS-485 / RS-232
Repeatability±0.5 ISO Code
Moisture Measurement Range0–100% RH
Temperature Sensing Range−20 to +80 °C
Channel Configuration4- or 6-channel, auto-adaptive
DisplayOLED with wide viewing angle
Input ControlDedicated tactile keys for分级 navigation and parameter configuration
Alarm FunctionReal-time contamination level alerting based on ISO 4406 thresholds
Bubble DiscriminationPatented full-spectrum optical discrimination algorithm for bubble rejection
Flow CompensationOnboard real-time flow rate calculation and viscosity-corrected particle counting
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
ModelML-1
Particle Detection Range5–150 µm
Sample Volume~10 mL per test
Analysis Time~3–5 min per sample
Operating Temperature−20 °C to +50 °C
Power Supply220 V AC / 50 Hz
Weight<16.65 kg
Compliant StandardsISO 4406, GJB-420B, NAS 1638
Detectable Particle TypesFatigue debris, cutting wear particles, sliding wear debris, non-metallic contaminants
Imaging SensorHigh-speed area-scan CMOS industrial camera
Optical ConfigurationDual-path (transmitted + reflected) illumination with telecentric lens
Dimensions (H×W×D)260 × 450 × 280 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
Instrument TypeOptical Particle Counter (Light Obscuration Principle)
ModelKLD-T
Sample CompatibilityHydraulic oil, lubricating oil, transformer oil (insulating oil), turbine oil (steam turbine oil), gear oil, engine oil, aviation kerosene, organic solvents, polymer solutions
Detection PrincipleLight obscuration (optical blockage) with custom-designed flow cell and precision optical assembly
Sampling MethodDual-mode pressure control (positive/negative pressure chamber for degassing and high-viscosity fluid handling)
User InterfaceBuilt-in bilingual toggle (Chinese/English)
Data StorageOnboard memory for traceable measurement records
ConnectivityRS-232 serial interface and Bluetooth 4.0 for host PC communication
Calibration & StandardsUser-configurable particle size channels
Regulatory ContextDesigned to support GLP-compliant workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
ModelZL-B
Power SupplyAC 220 V / 50 Hz or DC 9 V high-energy battery
Weight≤5 kg
Power Consumption≤300 mW
Battery LifeUp to 6 hours continuous operation
Dimensions (L×W×H)225 × 225 × 140 mm
Repeatability Error≤3%
Test ParametersComprehensive contamination index, water content, metallic debris >65 µm, presence of light hydrocarbon dilution
Classification Output“Poor”, “Usable”, or “Good”
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Beijing Hangfeng
OriginBeijing, China
ModelCS-01 / CS-02 / HQ-04
Operating Voltage18–30 VDC
Working Temperature−55 °C to +150 °C
Storage Temperature−55 °C to +70 °C
Max Working Pressure≤0.6 MPa
Sealing Performance≥0.3 MPa
Magnetic Pole Gap2.0 ± 0.1 mm (CS-01/CS-02), 1.7 ± 0.1 mm (HQ-04)
Magnetic Attraction Force≥50 g (CS-01/CS-02), ≥100 g (HQ-04)
Filtration Rating900 µm (CS-01), None (CS-02), 600 µm (HQ-04)
Ground Resistance≤20 mΩ
Insulation Resistance≥20 MΩ
Compatible FluidsMIL-PRF-23699 (GJB 1263–1991 compliant) synthetic aircraft lubricants (e.g., 4106, 4050)
Humidity Limit≤90% RH
Max Operational Altitude20,000 m
TBO1000 engine operating hours
Service Life4000 engine operating hours
Installation Interfaceφ18 flange (CS-01), M12×1.5 (CS-02), φ27 flange (HQ-04)
Dimensions≤φ41×72 mm (CS-01), ≤φ31×77 mm (CS-02), ≤φ54×82 mm (HQ-04)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
Manufacturer TypeAuthorized Distributor & Service Provider
Country of OriginChina
ModelKC
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
ModelKLD-3 / KLD-4 / KLD-5
Detection ParameterParticle Count & Contamination Level (NAS 1638)
Sample Volume10 mL
Compliance StandardNAS 1638
Power SupplyIntegrated Rechargeable Battery
DisplayColor LCD with Numeric and Graphical Output
Data OutputBuilt-in Thermal Printer
Application FocusLubricating Oil Condition Monitoring
CategoryPetroleum-Specialized Analytical Instrument for In-Service Oil Analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelWZL-1
PricingUpon Request
ComplianceASTM D86, ASTM D1078, ASTM D850
Measurement PrincipleAtmospheric distillation with integrated pressure-compensated volume and temperature tracking
Sample Volume10 mL
Test Duration≤15 min
DisplayIntegrated LCD interface
ConnectivityBluetooth 4.2
OutputBuilt-in thermal printer
Heating ControlAdaptive PID power modulation
Environmental CompensationReal-time ambient pressure, temperature, and volumetric correction
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
ModelYSF-1
Measurement PrincipleCapacitive Water Activity (a<sub>w</sub>) Sensing with Integrated Temperature Compensation
Output SignalsRS232 serial interface, 4–20 mA analog output
Relay Outputs2 programmable alarm channels
DisplayReal-time a<sub>w</sub> (0.01–1.00), temperature (°C), and calculated absolute water content (ppm)
CalibrationDual-point calibration support for traceable accuracy
PortabilityHandheld or inline mounting configuration
Compliance ContextDesigned for routine condition monitoring per IEC 60814, ASTM D6304 (Karl Fischer correlation), and IEEE C57.106 guidance for transformer oil moisture assessment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
ModelOCI-1B
Measurement PrincipleRotating Disc Electrode Atomic Emission Spectrometry (RDE-AES)
ComplianceASTM D6595
DetectorMulti-element high-resolution linear CCD array
Optical StabilityIntelligent temperature-controlled spectrometer housing (±0.1 °C)
Excitation SystemIntegrated intelligent棒 electrode dressing unit
Embedded ComputingIndustrial-grade embedded PC with thermal printer
Form FactorPortable benchtop unit with custom transit case
Sample Throughput< 90 s per oil sample (including electrode cleaning and analysis)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
ModelHMD-1
Measurement PrincipleOscillating U-tube (Digital Density Determination)
Sample Volume2 mL
DisplayColor LCD with backlighted viewing window
PowerRechargeable battery (≥6 h continuous operation)
Accuracy±0.001 g/cm³
Temperature ControlPeltier-assisted (±0.02 °C stability)
ComplianceISO 12084, ASTM D4052, USP <841>
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelKLD-B-2
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelFYH
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
ModelSD-1
Standards ComplianceASTM D6450, SH/T 0768, DL/T 1354
Measurement MethodClosed-Cup Pensky-Martens Equivalent (Automated Peltier-Cooled Ignition Detection)
Sample Volume≤ 2 mL
Test TimeTypically < 10 min per sample
Display7-inch Capacitive LCD Touchscreen (Android OS 8.1)
Data OutputThermal Printer (Built-in), USB Export, Optional Ethernet/Wi-Fi Module
Power SupplyAC 100–240 V, 50/60 Hz
Dimensions320 × 280 × 220 mm
Weight8.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelZL-Z
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
ModelKLD-BA
Detection PrincipleLight Obscuration (LO)
Compliance StandardsNAS 1638, GJB 420B, ISO 4406
Sample TypesHydraulic oil, lubricating oil, transformer oil, turbine oil, gear oil, engine oil, aviation kerosene, water-based hydraulic fluids, organic solvents, polymer solutions
Sensor TypeKLD-TC laser obscuration sensor
Display7-inch capacitive touchscreen (Android OS)
Data StorageInternal database with timestamped records
OutputThermal printer module, USB interface for data export and firmware updates
Sampling SystemPrecision metering pump with volumetric accuracy control
Calibration CurvesThree user-selectable curves (ACFTD, ISO MTD, GOST)
Reporting StandardsBuilt-in support for ISO 4406, NAS 1638, GJB 420A–1996, GJB 420B–2006, and seven additional particle contamination classification schemes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelDC
Instrument TypeOptical Particle Counter
Channel Diameter Options5 mm / 8 mm / 12 mm / 14 mm / 19 mm / 38 mm
Ferrous Particle Detection Ranges30–200 µm (micro), 200–300 µm (medium), >300 µm (large)
Non-Ferrous Particle Detection Ranges150–400 µm (micro), >400 µm (large)
Flow Rate Range1–10 L/min (DC-5) to 68–680 L/min (DC-38)
Operating Temperature−40 °C to +75 °C (standard)
Max Oil Temperature≤85 °C (standard)
Max System Pressure<2 MPa (standard)
Humidity<95% RH
Power Supply18–36 V DC
Communication ProtocolsCAN 2.0, RS-485, RS-422
Communication Isolation Voltage2500 V DC
Electrical Isolation Voltage1500 V DC
Bus Node Capacity32 nodes
Standby Current<0.25 A
Inrush Current<1 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
ModelHFN-B
Measurement PrincipleCapillary Efflux (ASTM D445 / ISO 3104 compliant)
Temperature Control40 °C ± 0.1 °C
Sample Volume80 µL
Measurement Time≤ 30 s per test
Viscosity Range2–1000 mm²/s (cSt) at 40 °C
CalibrationMulti-point viscosity standard calibration (certified mineral oil standards)
Display7-inch capacitive touchscreen
PowerRechargeable Li-ion battery (≥ 8 h continuous operation)
CleaningSolvent-free — dry wipe with lint-free industrial cloth
ComplianceDesigned to support ASTM D445, ISO 3104, and ISO 2909 procedures for kinematic viscosity determination
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelFHV-3
PricingUpon Request
Density Range600–1250 kg·m⁻³
Viscosity Range1–1000 cP
Temperature Range0–100 °C
Density Accuracy±0.5% or ±5 kg·m⁻³ (whichever is greater)
Viscosity Accuracy±5% or ±1 cP (whichever is greater)
Dielectric Constant Accuracy±3%
Temperature Accuracy±0.5 °C
ResolutionDensity 0.1 kg·m⁻³
Response Time<30 s (initial stabilization), 1 Hz data refresh rate
OutputRS485 MODBUS RTU
Power Supply9–32 VDC
Current Draw<20 mA @ 24 VDC
Max Process Pressure10 bar (custom options available)
Fluid Temp.0–100 °C
Ambient Temp.−40 to +85 °C
Storage Temp.−40 to +100 °C
Housing Material316/304 stainless steel or Hastelloy C-276
Mechanical InterfaceG3/4″
IP RatingIP65
Sealing MaterialFKM fluoroelastomer
Cable2 m M8 6-pin
Max Flow Velocity<0.1 m/s
ComplianceCE, ASTM D1657, EN 61326-1, EN 61326-2-3, ICES-003 Class B, National Metrology Verification Report
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Hangfeng
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHF
PricingAvailable Upon Request
Measurement PrincipleTransmission/Reflectance Near-Infrared Spectroscopy (NIRS) with PLS Regression Models
Sample Throughput≤3 min per sample
Sample PreparationNone required
Compliance StandardsGB/T 265, GB/T 1884, GB/T 261, GB/T 2430, GB/T 510, GB/T 6536
Calibration FlexibilityUser-definable PLS and MLR models for gasoline, diesel, jet fuel (Jet A-1), and blended fuels
Optical Range900–1700 nm (InGaAs detector)
Spectral Resolution≤8 nm
RepeatabilityRSD < 1.2% for key parameters (e.g., density, distillation T50, flash point)
Environmental RatingIP54, operating range −10 °C to +50 °C
Power SupplyIntegrated Li-ion battery (≥6 h continuous operation) or 12 V DC input
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0