| Brand | Automess |
|---|---|
| Origin | Germany |
| Model | 6150AD-5 |
| Detection Principle | GM tube-based photon (γ/X-ray) dosimetry |
| Energy Range | 45 keV – 3 MeV |
| Dose Rate Range (analog) | 1 µSv/h – 1000 mSv/h |
| Dose Rate Range (digital) | 0.1 µSv/h – 999 mSv/h |
| Power Supply | IEC 6LR61 9 V battery |
| Compliance | PTB-certified (Physikalisch-Technische Bundesanstalt, Germany) |
| Interface | RS232 serial port |
| External Probe Support | Yes (up to 100 m cable length) |
| Auto-probe Recognition | Yes |
| Memory | Non-volatile dose storage |
| Alarm Functions | Programmable dose & dose rate thresholds |
| Display | Analog needle + digital LCD with real-time avg/max/accumulated values |
| Brand | AUTOMESS |
|---|---|
| Origin | Germany |
| Model | 6150AD-6 |
| Type | Portable Dose Rate Meter |
| Measurement Principle | Ionization Chamber / GM Tube Based Photon Detection (γ/X-ray) |
| Energy Range | 60 keV – 1.3 MeV |
| Dose Rate Range (Digital) | 0.01 µSv/h – 9.99 mSv/h |
| Dose Rate Range (Analog) | 0.1 µSv/h – 10 mSv/h |
| Alarm Functions | Adjustable Dose & Dose Rate Thresholds |
| Interface | RS232 Serial Port |
| External Probe Support | Up to 100 m cable length (model-dependent) |
| Certification | PTB Certified (Physikalisch-Technische Bundesanstalt, Germany) |
| Power Supply | IEC 6LR61 9 V battery |
| Compliance | Designed for IEC 60846, IEC 61017, and ISO 4037-3 referenced radiation protection applications |
| Brand | ATOMTEX |
|---|---|
| Origin | Belarus |
| Model | AT1121 |
| Detection Principle | Scintillation (plastic scintillator with heavy metal admixture) |
| Measuring Quantity | Ambient Dose Equivalent H*(10) |
| Continuous Dose Rate Range | 50 nSv/h – 10 Sv/h |
| Short-Term Dose Rate Range | 5 µSv/h – 10 Sv/h |
| Pulse Dose Rate Capability | Down to 10 ns (for AT1123 variant |
| Energy Range | 15 keV – 10 MeV |
| β Detection | Yes (with optional collimator/filter cap) |
| Display | Backlit LCD |
| Data Storage | 100 measurements |
| Interface | RS-232, 300–19200 baud |
| Operating Temperature | −30 °C to +40 °C |
| IP Rating | IP54 |
| Weight | 0.9 kg |
| Dimensions | 233 × 85 × 67 mm |
| Power | Rechargeable 6 V battery / AC 220 V / DC 12 V |
| Compliance | IEC 61000-4-2:1995, IEC 61000-4-3:1995, CISPR 22:1997 |
| Brand | ARA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LFR-6 |
| Weight | 15 lb |
| Flow Rate | 6 L/min (adjustable 3–10 L/min) |
| Flow Accuracy | ±2% |
| Battery | 18 V Li-ion (rechargeable, 1 hr charge time, >30 hr runtime) |
| Data Logging Interval | 5 min |
| Dimensions | 10" × 12" × 7" |
| Data Export | USB flash drive |
| Filter Format | 47 mm FRM-compatible |
| Sampling Modes | TSP, PM₁₀, PM₂.₅ |
| Optional Sensors | Real-time particulate (RTP), PEET anemometer, optical scattering sensor |
| Compliance | Designed to meet U.S. EPA Reference Method (FRM) criteria for low-flow ambient particulate monitoring |
| Brand | ARA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FTS |
| Pricing | Available Upon Request |
| Enclosure Dimensions | 10.62" × 9.68" × 4.87" (27 cm × 24.6 cm × 12.4 cm) |
| Enclosure Weight | 5 lbs (2.27 kg) |
| Flow Ranges | 1–3 LPM, 2–9 LPM, and 9–25 LPM |
| Flow Accuracy | ±1% of reading |
| Temperature Range | −30°C to +50°C |
| Temperature Accuracy | ±0.5°C |
| Barometric Pressure Range | 250–800 mmHg |
| Pressure Accuracy | ±5 mmHg |
| Battery Type | Rechargeable NiMH |
| Battery Life | Up to 60 hours |
| Calibration Traceability | NIST-traceable |
| Flow Measurement Principle | Venturi-based differential pressure |
| Environmental Rating | IP65-rated weather-resistant enclosure |
| Connectivity | Integrated Bluetooth 5.0 for iOS/Android mobile devices |
| Standard Conditions Configuration | User-definable STP (Standard Temperature and Pressure) settings |
| Brand | ARA |
|---|---|
| Origin | USA |
| Model | N-FRM |
| Flow Rate | 10–20 LPM (nominal 16.7 LPM) |
| Flow Accuracy | ±2% (±1% with calibration) |
| Operating Time | >30 hours on rechargeable 18 V lithium battery |
| Charging Time | 1 hour |
| Data Output | USB flash drive |
| Dimensions | 25.4 × 30.48 × 17.78 cm |
| Sampling Weight | 15 lbs |
| Shipping Weight | 25 lbs |
| Filter Holder | Standard FRM-compliant 47 mm cassette mount |
| Particle Separation | Low-maintenance, oil-free cyclonic inlet for PM₂.₅ and PM₁₀ |
| Brand | AII |
|---|---|
| Origin | USA |
| Model | GPR-1200 |
| Weight | 5.4 kg (12 lbs) |
| Measurement Range | 0–1 ppm to 0–100% O₂ |
| Accuracy | < 2% of reading or 0.2 ppm (whichever is greater) |
| Response Time (T90) | < 13 s |
| Detection Limit | 0.05 ppm |
| Sensor Lifetime | 24–32 months (at ≤1000 ppm O₂) |
| Battery Life | Up to 30 days (standby), 40 hours (with internal pump active) |
| Operating Temperature | 5–45°C (GPR sensor) |
| Enclosure | Painted aluminum, NEMA 4X rated |
| Gas Inlet | 1/8" compression fitting |
| Pressure Range | 0.34–2 barg (5–30 psig) with vent |
| Output | 0–1 V analog |
| Compliance | ATEX Ex II 2 G Ex ib IIC T4 Gb, Tamb 5°C to +45°C |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | POM |
| Instrument Type | Portable |
| Measurement Range | 0–10 ppm |
| LOD | 4 ppb |
| Response Time | 10 s |
| Zero Drift | 1.5 ppb |
| Resolution | 1 ppb |
| Detection Principle | UV Absorption at 254 nm |
| FEM Designation | EQOA-0815-227 |
| NIST-Traceable Calibration | Yes |
| Operating Temperature | 0–50 °C |
| Pressure Range | 150–1013 mbar |
| Data Storage Capacity | 8,192 records |
| Power | 7.4 V Li-ion battery (5–8 h) or AC adapter (100–240 VAC to 12 VDC) |
| Dimensions (with GPS) | 12.7 × 7.6 × 3.8 cm |
| Weight (with battery) | 450 g |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 106MH |
| Instrument Type | Fixed-mount ozone analyzer |
| Measurement Range | 0–10,000 ppm (0–1 vol%) |
| Response Time | 2 s |
| Measurement Interval | 2 s |
| Detection Principle | UV absorption at 254 nm |
| Flow Rate | 1 L/min |
| Data Storage | 32,736 rows (e.g., 113 days at 5-min averaging) |
| Output Interfaces | USB, RS-232, 0–2.5 V analog, 4–20 mA |
| Display | Integrated LCD |
| Power | 11–28 VDC, 500 mA, 6 W |
| Dimensions | 9 × 20 × 24 cm (3.65 × 7.9 × 9.4 in) |
| Weight | 1.9 kg (4.2 lb) |
| Compliance | Designed for continuous environmental and industrial monitoring per EPA, ISO 13964, and ASTM D5012 practices |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 106M |
| Weight | 2.1 kg (4.7 lb) |
| Measurement Principle | UV absorption at 254 nm |
| Range | 0–1000 ppmv |
| Resolution | 0.01 ppmv |
| Accuracy | ±0.01 ppmv or ±2% of reading |
| Sampling Interval | 10 s (configurable averaging: 10 s, 1 min, 5 min, 1 hr) |
| Flow Rate | ~1 L/min |
| Data Storage | 12,288 points |
| Output Interfaces | USB, RS-232, 0–2.5 V analog, 4–20 mA |
| Power | 12 V DC or 120/240 V AC, 4.2 W |
| Dimensions | 9.5 × 21.0 × 21.6 cm (3.75 × 8.25 × 8.50 in) |
| Compliance | NIST-traceable calibration, compatible with EPA reference method EQOA-0808-191 for ozone monitoring |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Model 306 OCS |
| Instrument Type | Portable |
| Measurement Range | 0–1,000 ppbv (selectable from 0, 30, 50, 100, 200, 500, 1000 ppbv) |
| Detection Limit | 0 ppbv (zero reference capability) |
| Response Time (t₉₅) | <35 s |
| Zero Drift | ≤1% of full scale per 24 h |
| Resolution | 2 ppbv |
| Ozone Generation Principle | Photolysis of O₂ at 185 nm |
| Total Flow Rate | 2.5 L/min (±5%) |
| Dimensions | 90 × 210 × 290 mm |
| Weight | 2.6 kg |
| Power Supply | 12 VDC or 100–240 VAC, 50/60 Hz, 18 W |
| NIST-Traceable Calibration | Yes |
| Environmental Independence | Controlled ozone mixing ratio unaffected by ambient temperature, pressure, or humidity |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 202 |
| Instrument Type | Portable |
| Measurement Range | 0–250 ppm |
| Detection Limit | 1 ppb |
| Response Time | 2 s |
| Zero Drift | ±1 ppb/24 h |
| Resolution | 1 ppb |
| Operating Voltage | 12 V DC |
| Power Consumption | 4.0 W (2.9 W in low-power mode) |
| Flow Rate | ~1 L/min |
| Data Storage Capacity | 20,480 records |
| Measurement Interval | 10 s (configurable averaging: 10 s, 1 min, 5 min, 1 hr) |
| Output Interfaces | RS-232 / USB / 0–2.5 V analog |
| Input Channels | 3 × 0–2.5 V analog |
| Display | Integrated LCD |
| Units Supported | ppm, ppb, pphm, g/Nm³, µg/m³ |
| EPA FEM Designation | EQOA-0410-190 |
| Compliance | 40 CFR Part 58 Appendix A |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | BCP |
| Measurement Principle | Dual-wavelength (405 nm & 880 nm) direct extinction photometry |
| Dynamic Range | 0–10,000 Mm⁻¹ (880 nm: ~0–1300 µg·m⁻³) |
| Resolution | 0.1 Mm⁻¹ (0.1 µg·m⁻³) |
| Accuracy | ±2 Mm⁻¹ or ±2% of reading |
| Detection Limit (2σ, 1-hr avg) | 0.036 µg·m⁻³ at 880 nm |
| Flow Rate | 1.3 L·min⁻¹ (range: 1.0–1.6 L·min⁻¹) |
| Response Time (100% step, adaptive filter) | 20 s |
| Power Consumption | ~16 W (avg, post-warm-up) |
| Dimensions | 43 × 37 × 14 cm (17" × 14.5" × 5.5", rack-mountable) |
| Weight | 8.7 kg (19.2 lb) |
| Data Storage | 10 GB internal (≥3.2 years @ 10-s intervals) |
| Operating Temp | 5–45 °C |
| Pressure Range | 600–1000 mbar |
| Output Interfaces | RS-232, USB, 0–2.5 V analog (user-scaled), touchscreen GUI |
| Pump Lifetime | ~15,000 h |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 714 |
| NO₂ Range | 0–500 ppb |
| NO Range | 0–1000 ppb |
| O₃ Range | 0–500 ppb |
| Output Flow | 2.0–3.5 L/min (typ. 2.5–3.0 L/min) |
| Accuracy | ±2.0 ppb or ±2.0% of reading (whichever is greater) |
| Response Time to 95% of Setpoint | <30 s |
| Power | 12 V DC, 3.5 A max (42 Wh), or 100–240 V AC, 5 A |
| Dimensions (Rack-Mount) | 43 × 37 × 14 cm (17" × 14.5" × 5.5") |
| Weight | 7.0 kg (15.5 lb) |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–60 °C |
| Relative Humidity | 0–80% RH (non-condensing) |
| Altitude | 0–2000 m |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | ASPIDA |
| Instrument Type | Portable |
| Detection Target | Single-component (CO₂) |
| Measurement Range | 0.01–5.00% vol CO₂ |
| Resolution | 0.01% vol |
| Accuracy | ±2% FS (0.01–2.5% range), ±3% FS (2.5–5.0% range) |
| Response Time (T90) | <60 s |
| Zero Drift | <±1% FS/6 months |
| Span Drift | <±1% FS/6 months |
| Linearity Error | ≤1% FS |
| Operating Temperature | –5 to +50 °C |
| Battery | 2×2100 mAh NiMH AA |
| Runtime | >12 h per charge |
| Charging Time | 4.5 h |
| Display | High-visibility OLED |
| Audible Alarm | 95 dB @ 30 cm (110 dB for fall detection) |
| Visual Indicators | 1 green LED (normal), 1 yellow LED (fault), 3 red LEDs (alarm) |
| Sensor Technology | Non-dispersive infrared (NDIR), MIR-based |
| CO₂ Sensor Lifetime | 5 years |
| Optional O₂ Sensor | Electrochemical, 0.1–25.0% vol, T90 <30 s, lifetime 2 years |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | SDA-CO2 |
| Sensor Range | 0–5000 ppm and 0–2% CO₂ |
| Accuracy | ±25 ppm or ±1% of reading (0–5000 ppm) |
| Display | Full-color graphical LCD |
| Output Options | 4–20 mA, relay, Ethernet (protocol available on request) |
| Data Logging | Optional internal memory |
| Alarm | Configurable audio/visual alerts via front panel |
| Compliance | DNV, IMCA, Lloyd’s Register, ABS, ADCI |
| Sensor Type | Dual-beam NDIR (Non-Dispersive Infrared) |
| Mounting | Rack-mountable or panel-mountable |
| Replacement Sensor | Advanced digital 5S3 NDIR sensor |
| Legacy Compatibility | Direct drop-in replacement for Analox 5001 |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 106H |
| Instrument Type | Portable |
| Measurement Range | 1.5 ppbv to 100 ppmv |
| LOD | 1 ppbv |
| Response Time | 10 s |
| Zero Drift | ±1 ppbv (24 h) |
| Resolution | 0.01 wt% (for 106H configuration) |
| Detection Principle | UV Absorption at 254 nm |
| Flow Rate | ~1 L/min |
| Data Storage | 12,288 points |
| Output Interfaces | USB, RS-232, 0–2.5 V analog, 4–20 mA |
| Power | 12 V DC or 120/240 V AC, 4.2 W |
| Dimensions | 9.5 × 21.0 × 21.6 cm |
| Weight | 2.1 kg |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 106W |
| Instrument Type | Portable |
| Measurement Range | 0–100 ppm |
| Detection Limit | 0.05 ppm (or ±1% of reading) |
| Response Time | <10 seconds (t₉₀) |
| Zero Drift | <0.02 ppm/24 h |
| Resolution | 0.01 ppm |
| Flow Rate | ~12 mL/min |
| Data Storage | 16,368 records |
| Sampling Interval Options | 10 s, 1 min, 5 min, 1 h |
| Output Interfaces | RS-232 serial, 0–2.5 V analog, LCD display, LED alarm |
| Power Supply | 12 V DC or 100–240 V AC, 5.0 W (3.9 W in low-power mode) |
| Dimensions | 33.8 × 30.5 × 18.5 cm |
| Weight | 6.6 kg |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | UV-106-W |
| Instrument Type | Portable |
| Measurement Range | 0–100 ppm (g/m³, µg/mL, mg/L) |
| Detection Limit | 1 ppb (0.001 ppm) |
| Response Time | 20 s |
| Zero Drift | <0.05 ppm/month |
| Resolution | 0.1 ppm |
| Sampling Flow Rate | 12 mL/min |
| Operating Pressure | 0–50 psi (burst pressure >100 psi) |
| Power | 11–14 VDC, 2.2 A @ 12 V (26.4 W) |
| Data Logging Capacity | 16,368 records |
| Dimensions | 33.8 × 30.5 × 18.5 cm |
| Weight | 6.6 kg |
| Brand | ANDalyze |
|---|---|
| Origin | USA |
| Model | AND1100 |
| Measurement Principle | DNAzyme-based Fluorescence Detection |
| Detection Time | ≤60 s per sample |
| Detection Units | ppb or ppm |
| IP Rating | IP54 |
| Certifications | CE |
| Data Interface | USB |
| Software Update | Over-the-air via USB |
| Operating Languages | Multilingual (including Chinese) |
| Sensor Format | Discrete color-coded single-use cartridges |
| Sample Volume | 1 mL |
| Power | Rechargeable battery (USB charging) |
| Brand | ANALOX |
|---|---|
| Origin | United Kingdom |
| Model | HYP-MO2HBYY03 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical (Clark-type pO₂ sensor) |
| Range | 0–2 bar ppO₂ |
| Accuracy | ±1% of reading ±1 LSD |
| Temperature Effect | ±0.2% of reading / °C |
| Long-term Drift | ≤5% of reading per year |
| Zero Drift | <1% FS/year |
| Span Drift | <1% FS/year |
| Linearity Error | ±1% FS |
| Resolution | 0.01 bar ppO₂ |
| Repeatability | ±1% FS |
| Operating Temperature | 0–40 °C |
| Operating Pressure | 0.8–60 bar absolute (≈600 msw / 2000 fsw) |
| Compression/Decompression Rate Limit | <2 bar/min |
| Power Supply | 9 V PP3 battery |
| Battery Life | 800 h continuous operation |
| Dimensions | 64 × 98 × 36 mm |
| Weight | 0.200 kg |
| Sensor Module | Analox 9100-9212-5H |
| Optional Probe | 9100-9212-2 |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | Aspida O₂ |
| Instrument Type | Portable |
| Measurement Range | 0.1–25% O₂ (v/v) |
| Accuracy | ±0.0075% O₂ |
| Resolution | 0.1% O₂ |
| Repeatability | ±1% of reading |
| Zero Drift | <1% O₂ per month |
| Span Drift | <1% O₂ per month |
| Linearity Error | ±1% of full scale |
| Visual Indication | Green (normal), Amber (fault), Triple Red (alarm) |
| Audible Alarm | 95 dB @ 30 cm |
| Emergency Alarm | 110 dB @ 30 cm |
| Vibration Alert | Yes |
| T90 Response Time | <30 s |
| Operating Temperature | −5 °C to +50 °C |
| IP Rating | IP65 |
| Dimensions | 127 mm × 44 mm × 90 mm |
| Weight | 355 g |
| Power | Dual-mode — rechargeable Li-ion battery or two AA alkaline cells |
| Data Logging | Time-weighted average (TWA), STEL, peak hold |
| Compliance | ATEX II 2G Ex ib IIC T4 Gb, IECEx Ex ib IIC T4 Gb, UKCA, CE |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 106L |
| Instrument Type | Portable |
| Measurement Range | 1.5 ppbv – 100 ppmv |
| LOD | 1.5 ppbv |
| Response Time | 10 s |
| Zero Drift | ±1 ppbv (24 h) |
| Resolution | 1.5 ppbv |
| Accuracy | ±2 ppbv or ±2% of reading |
| Sampling Flow Rate | ~1 L/min |
| Data Storage | 12,288 points |
| Output Interfaces | USB, RS-232, 0–2.5 V analog, 4–20 mA |
| Power | 12 V DC or 120/240 V AC, 4.2 W |
| Dimensions | 9.5 × 21.0 × 21.6 cm |
| Weight | 2.1 kg |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 106-M |
| Instrument Type | Portable |
| Measurement Range | 0–1000 ppm |
| Limit of Detection | 0.01 ppm |
| Response Time | 10 s |
| Zero Drift | ±1 ppbv (24 h) |
| Resolution | 1.5 ppbv |
| Power Consumption | 4.2 W |
| Dimensions | 9.5 × 21.0 × 21.6 cm |
| Weight | 2.1 kg |
| Sampling Flow Rate | ~1 L/min |
| Data Storage Capacity | 12,288 points |
| Output Interfaces | USB, RS-232, 0–2.5 V analog, 4–20 mA analog |
| Calibration Traceability | NIST-traceable ozone standard |
Show next