Empowering Scientific Discovery

Beijing Huayitongtai Environmental Protection Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAutomess
OriginGermany
Model6150AD-5
Detection PrincipleGM tube-based photon (γ/X-ray) dosimetry
Energy Range45 keV – 3 MeV
Dose Rate Range (analog)1 µSv/h – 1000 mSv/h
Dose Rate Range (digital)0.1 µSv/h – 999 mSv/h
Power SupplyIEC 6LR61 9 V battery
CompliancePTB-certified (Physikalisch-Technische Bundesanstalt, Germany)
InterfaceRS232 serial port
External Probe SupportYes (up to 100 m cable length)
Auto-probe RecognitionYes
MemoryNon-volatile dose storage
Alarm FunctionsProgrammable dose & dose rate thresholds
DisplayAnalog needle + digital LCD with real-time avg/max/accumulated values
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAUTOMESS
OriginGermany
Model6150AD-6
TypePortable Dose Rate Meter
Measurement PrincipleIonization Chamber / GM Tube Based Photon Detection (γ/X-ray)
Energy Range60 keV – 1.3 MeV
Dose Rate Range (Digital)0.01 µSv/h – 9.99 mSv/h
Dose Rate Range (Analog)0.1 µSv/h – 10 mSv/h
Alarm FunctionsAdjustable Dose & Dose Rate Thresholds
InterfaceRS232 Serial Port
External Probe SupportUp to 100 m cable length (model-dependent)
CertificationPTB Certified (Physikalisch-Technische Bundesanstalt, Germany)
Power SupplyIEC 6LR61 9 V battery
ComplianceDesigned for IEC 60846, IEC 61017, and ISO 4037-3 referenced radiation protection applications
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATOMTEX
OriginBelarus
ModelAT1121
Detection PrincipleScintillation (plastic scintillator with heavy metal admixture)
Measuring QuantityAmbient Dose Equivalent H*(10)
Continuous Dose Rate Range50 nSv/h – 10 Sv/h
Short-Term Dose Rate Range5 µSv/h – 10 Sv/h
Pulse Dose Rate CapabilityDown to 10 ns (for AT1123 variant
Energy Range15 keV – 10 MeV
β DetectionYes (with optional collimator/filter cap)
DisplayBacklit LCD
Data Storage100 measurements
InterfaceRS-232, 300–19200 baud
Operating Temperature−30 °C to +40 °C
IP RatingIP54
Weight0.9 kg
Dimensions233 × 85 × 67 mm
PowerRechargeable 6 V battery / AC 220 V / DC 12 V
ComplianceIEC 61000-4-2:1995, IEC 61000-4-3:1995, CISPR 22:1997
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARA
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelLFR-6
Weight15 lb
Flow Rate6 L/min (adjustable 3–10 L/min)
Flow Accuracy±2%
Battery18 V Li-ion (rechargeable, 1 hr charge time, >30 hr runtime)
Data Logging Interval5 min
Dimensions10" × 12" × 7"
Data ExportUSB flash drive
Filter Format47 mm FRM-compatible
Sampling ModesTSP, PM₁₀, PM₂.₅
Optional SensorsReal-time particulate (RTP), PEET anemometer, optical scattering sensor
ComplianceDesigned to meet U.S. EPA Reference Method (FRM) criteria for low-flow ambient particulate monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARA
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelFTS
PricingAvailable Upon Request
Enclosure Dimensions10.62" × 9.68" × 4.87" (27 cm × 24.6 cm × 12.4 cm)
Enclosure Weight5 lbs (2.27 kg)
Flow Ranges1–3 LPM, 2–9 LPM, and 9–25 LPM
Flow Accuracy±1% of reading
Temperature Range−30°C to +50°C
Temperature Accuracy±0.5°C
Barometric Pressure Range250–800 mmHg
Pressure Accuracy±5 mmHg
Battery TypeRechargeable NiMH
Battery LifeUp to 60 hours
Calibration TraceabilityNIST-traceable
Flow Measurement PrincipleVenturi-based differential pressure
Environmental RatingIP65-rated weather-resistant enclosure
ConnectivityIntegrated Bluetooth 5.0 for iOS/Android mobile devices
Standard Conditions ConfigurationUser-definable STP (Standard Temperature and Pressure) settings
Added to wishlistRemoved from wishlist 0
Add to compare
BrandARA
OriginUSA
ModelN-FRM
Flow Rate10–20 LPM (nominal 16.7 LPM)
Flow Accuracy±2% (±1% with calibration)
Operating Time>30 hours on rechargeable 18 V lithium battery
Charging Time1 hour
Data OutputUSB flash drive
Dimensions25.4 × 30.48 × 17.78 cm
Sampling Weight15 lbs
Shipping Weight25 lbs
Filter HolderStandard FRM-compliant 47 mm cassette mount
Particle SeparationLow-maintenance, oil-free cyclonic inlet for PM₂.₅ and PM₁₀
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-1200
Weight5.4 kg (12 lbs)
Measurement Range0–1 ppm to 0–100% O₂
Accuracy< 2% of reading or 0.2 ppm (whichever is greater)
Response Time (T90)< 13 s
Detection Limit0.05 ppm
Sensor Lifetime24–32 months (at ≤1000 ppm O₂)
Battery LifeUp to 30 days (standby), 40 hours (with internal pump active)
Operating Temperature5–45°C (GPR sensor)
EnclosurePainted aluminum, NEMA 4X rated
Gas Inlet1/8" compression fitting
Pressure Range0.34–2 barg (5–30 psig) with vent
Output0–1 V analog
ComplianceATEX Ex II 2 G Ex ib IIC T4 Gb, Tamb 5°C to +45°C
Added to wishlistRemoved from wishlist 0
Add to compare
Brand2B Technologies
OriginUSA
ModelPOM
Instrument TypePortable
Measurement Range0–10 ppm
LOD4 ppb
Response Time10 s
Zero Drift1.5 ppb
Resolution1 ppb
Detection PrincipleUV Absorption at 254 nm
FEM DesignationEQOA-0815-227
NIST-Traceable CalibrationYes
Operating Temperature0–50 °C
Pressure Range150–1013 mbar
Data Storage Capacity8,192 records
Power7.4 V Li-ion battery (5–8 h) or AC adapter (100–240 VAC to 12 VDC)
Dimensions (with GPS)12.7 × 7.6 × 3.8 cm
Weight (with battery)450 g
Added to wishlistRemoved from wishlist 0
Add to compare
Brand2B Technologies
OriginUSA
ModelModel 106MH
Instrument TypeFixed-mount ozone analyzer
Measurement Range0–10,000 ppm (0–1 vol%)
Response Time2 s
Measurement Interval2 s
Detection PrincipleUV absorption at 254 nm
Flow Rate1 L/min
Data Storage32,736 rows (e.g., 113 days at 5-min averaging)
Output InterfacesUSB, RS-232, 0–2.5 V analog, 4–20 mA
DisplayIntegrated LCD
Power11–28 VDC, 500 mA, 6 W
Dimensions9 × 20 × 24 cm (3.65 × 7.9 × 9.4 in)
Weight1.9 kg (4.2 lb)
ComplianceDesigned for continuous environmental and industrial monitoring per EPA, ISO 13964, and ASTM D5012 practices
Added to wishlistRemoved from wishlist 0
Add to compare
Brand2B Technologies
OriginUSA
ModelModel 106M
Weight2.1 kg (4.7 lb)
Measurement PrincipleUV absorption at 254 nm
Range0–1000 ppmv
Resolution0.01 ppmv
Accuracy±0.01 ppmv or ±2% of reading
Sampling Interval10 s (configurable averaging: 10 s, 1 min, 5 min, 1 hr)
Flow Rate~1 L/min
Data Storage12,288 points
Output InterfacesUSB, RS-232, 0–2.5 V analog, 4–20 mA
Power12 V DC or 120/240 V AC, 4.2 W
Dimensions9.5 × 21.0 × 21.6 cm (3.75 × 8.25 × 8.50 in)
ComplianceNIST-traceable calibration, compatible with EPA reference method EQOA-0808-191 for ozone monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
Brand2B Technologies
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelModel 306 OCS
Instrument TypePortable
Measurement Range0–1,000 ppbv (selectable from 0, 30, 50, 100, 200, 500, 1000 ppbv)
Detection Limit0 ppbv (zero reference capability)
Response Time (t₉₅)<35 s
Zero Drift≤1% of full scale per 24 h
Resolution2 ppbv
Ozone Generation PrinciplePhotolysis of O₂ at 185 nm
Total Flow Rate2.5 L/min (±5%)
Dimensions90 × 210 × 290 mm
Weight2.6 kg
Power Supply12 VDC or 100–240 VAC, 50/60 Hz, 18 W
NIST-Traceable CalibrationYes
Environmental IndependenceControlled ozone mixing ratio unaffected by ambient temperature, pressure, or humidity
Added to wishlistRemoved from wishlist 0
Add to compare
Brand2B Technologies
OriginUSA
ModelModel 202
Instrument TypePortable
Measurement Range0–250 ppm
Detection Limit1 ppb
Response Time2 s
Zero Drift±1 ppb/24 h
Resolution1 ppb
Operating Voltage12 V DC
Power Consumption4.0 W (2.9 W in low-power mode)
Flow Rate~1 L/min
Data Storage Capacity20,480 records
Measurement Interval10 s (configurable averaging: 10 s, 1 min, 5 min, 1 hr)
Output InterfacesRS-232 / USB / 0–2.5 V analog
Input Channels3 × 0–2.5 V analog
DisplayIntegrated LCD
Units Supportedppm, ppb, pphm, g/Nm³, µg/m³
EPA FEM DesignationEQOA-0410-190
Compliance40 CFR Part 58 Appendix A
Added to wishlistRemoved from wishlist 0
Add to compare
Brand2B Technologies
OriginUSA
ModelBCP
Measurement PrincipleDual-wavelength (405 nm & 880 nm) direct extinction photometry
Dynamic Range0–10,000 Mm⁻¹ (880 nm: ~0–1300 µg·m⁻³)
Resolution0.1 Mm⁻¹ (0.1 µg·m⁻³)
Accuracy±2 Mm⁻¹ or ±2% of reading
Detection Limit (2σ, 1-hr avg)0.036 µg·m⁻³ at 880 nm
Flow Rate1.3 L·min⁻¹ (range: 1.0–1.6 L·min⁻¹)
Response Time (100% step, adaptive filter)20 s
Power Consumption~16 W (avg, post-warm-up)
Dimensions43 × 37 × 14 cm (17" × 14.5" × 5.5", rack-mountable)
Weight8.7 kg (19.2 lb)
Data Storage10 GB internal (≥3.2 years @ 10-s intervals)
Operating Temp5–45 °C
Pressure Range600–1000 mbar
Output InterfacesRS-232, USB, 0–2.5 V analog (user-scaled), touchscreen GUI
Pump Lifetime~15,000 h
Added to wishlistRemoved from wishlist 0
Add to compare
Brand2B Technologies
OriginUSA
ModelModel 714
NO₂ Range0–500 ppb
NO Range0–1000 ppb
O₃ Range0–500 ppb
Output Flow2.0–3.5 L/min (typ. 2.5–3.0 L/min)
Accuracy±2.0 ppb or ±2.0% of reading (whichever is greater)
Response Time to 95% of Setpoint<30 s
Power12 V DC, 3.5 A max (42 Wh), or 100–240 V AC, 5 A
Dimensions (Rack-Mount)43 × 37 × 14 cm (17" × 14.5" × 5.5")
Weight7.0 kg (15.5 lb)
Operating Temperature0–40 °C
Storage Temperature−20–60 °C
Relative Humidity0–80% RH (non-condensing)
Altitude0–2000 m
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalox
OriginUnited Kingdom
ModelASPIDA
Instrument TypePortable
Detection TargetSingle-component (CO₂)
Measurement Range0.01–5.00% vol CO₂
Resolution0.01% vol
Accuracy±2% FS (0.01–2.5% range), ±3% FS (2.5–5.0% range)
Response Time (T90)<60 s
Zero Drift<±1% FS/6 months
Span Drift<±1% FS/6 months
Linearity Error≤1% FS
Operating Temperature–5 to +50 °C
Battery2×2100 mAh NiMH AA
Runtime>12 h per charge
Charging Time4.5 h
DisplayHigh-visibility OLED
Audible Alarm95 dB @ 30 cm (110 dB for fall detection)
Visual Indicators1 green LED (normal), 1 yellow LED (fault), 3 red LEDs (alarm)
Sensor TechnologyNon-dispersive infrared (NDIR), MIR-based
CO₂ Sensor Lifetime5 years
Optional O₂ SensorElectrochemical, 0.1–25.0% vol, T90 <30 s, lifetime 2 years
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalox
OriginUnited Kingdom
ModelSDA-CO2
Sensor Range0–5000 ppm and 0–2% CO₂
Accuracy±25 ppm or ±1% of reading (0–5000 ppm)
DisplayFull-color graphical LCD
Output Options4–20 mA, relay, Ethernet (protocol available on request)
Data LoggingOptional internal memory
AlarmConfigurable audio/visual alerts via front panel
ComplianceDNV, IMCA, Lloyd’s Register, ABS, ADCI
Sensor TypeDual-beam NDIR (Non-Dispersive Infrared)
MountingRack-mountable or panel-mountable
Replacement SensorAdvanced digital 5S3 NDIR sensor
Legacy CompatibilityDirect drop-in replacement for Analox 5001
Added to wishlistRemoved from wishlist 0
Add to compare
Brand2B Technologies
OriginUSA
ModelModel 106H
Instrument TypePortable
Measurement Range1.5 ppbv to 100 ppmv
LOD1 ppbv
Response Time10 s
Zero Drift±1 ppbv (24 h)
Resolution0.01 wt% (for 106H configuration)
Detection PrincipleUV Absorption at 254 nm
Flow Rate~1 L/min
Data Storage12,288 points
Output InterfacesUSB, RS-232, 0–2.5 V analog, 4–20 mA
Power12 V DC or 120/240 V AC, 4.2 W
Dimensions9.5 × 21.0 × 21.6 cm
Weight2.1 kg
Added to wishlistRemoved from wishlist 0
Add to compare
Brand2B Technologies
OriginUSA
ModelModel 106W
Instrument TypePortable
Measurement Range0–100 ppm
Detection Limit0.05 ppm (or ±1% of reading)
Response Time<10 seconds (t₉₀)
Zero Drift<0.02 ppm/24 h
Resolution0.01 ppm
Flow Rate~12 mL/min
Data Storage16,368 records
Sampling Interval Options10 s, 1 min, 5 min, 1 h
Output InterfacesRS-232 serial, 0–2.5 V analog, LCD display, LED alarm
Power Supply12 V DC or 100–240 V AC, 5.0 W (3.9 W in low-power mode)
Dimensions33.8 × 30.5 × 18.5 cm
Weight6.6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
Brand2B Technologies
OriginUSA
ModelUV-106-W
Instrument TypePortable
Measurement Range0–100 ppm (g/m³, µg/mL, mg/L)
Detection Limit1 ppb (0.001 ppm)
Response Time20 s
Zero Drift<0.05 ppm/month
Resolution0.1 ppm
Sampling Flow Rate12 mL/min
Operating Pressure0–50 psi (burst pressure >100 psi)
Power11–14 VDC, 2.2 A @ 12 V (26.4 W)
Data Logging Capacity16,368 records
Dimensions33.8 × 30.5 × 18.5 cm
Weight6.6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANDalyze
OriginUSA
ModelAND1100
Measurement PrincipleDNAzyme-based Fluorescence Detection
Detection Time≤60 s per sample
Detection Unitsppb or ppm
IP RatingIP54
CertificationsCE
Data InterfaceUSB
Software UpdateOver-the-air via USB
Operating LanguagesMultilingual (including Chinese)
Sensor FormatDiscrete color-coded single-use cartridges
Sample Volume1 mL
PowerRechargeable battery (USB charging)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANALOX
OriginUnited Kingdom
ModelHYP-MO2HBYY03
Instrument TypePortable
Measurement PrincipleElectrochemical (Clark-type pO₂ sensor)
Range0–2 bar ppO₂
Accuracy±1% of reading ±1 LSD
Temperature Effect±0.2% of reading / °C
Long-term Drift≤5% of reading per year
Zero Drift<1% FS/year
Span Drift<1% FS/year
Linearity Error±1% FS
Resolution0.01 bar ppO₂
Repeatability±1% FS
Operating Temperature0–40 °C
Operating Pressure0.8–60 bar absolute (≈600 msw / 2000 fsw)
Compression/Decompression Rate Limit<2 bar/min
Power Supply9 V PP3 battery
Battery Life800 h continuous operation
Dimensions64 × 98 × 36 mm
Weight0.200 kg
Sensor ModuleAnalox 9100-9212-5H
Optional Probe9100-9212-2
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalox
OriginUnited Kingdom
ModelAspida O₂
Instrument TypePortable
Measurement Range0.1–25% O₂ (v/v)
Accuracy±0.0075% O₂
Resolution0.1% O₂
Repeatability±1% of reading
Zero Drift<1% O₂ per month
Span Drift<1% O₂ per month
Linearity Error±1% of full scale
Visual IndicationGreen (normal), Amber (fault), Triple Red (alarm)
Audible Alarm95 dB @ 30 cm
Emergency Alarm110 dB @ 30 cm
Vibration AlertYes
T90 Response Time<30 s
Operating Temperature−5 °C to +50 °C
IP RatingIP65
Dimensions127 mm × 44 mm × 90 mm
Weight355 g
PowerDual-mode — rechargeable Li-ion battery or two AA alkaline cells
Data LoggingTime-weighted average (TWA), STEL, peak hold
ComplianceATEX II 2G Ex ib IIC T4 Gb, IECEx Ex ib IIC T4 Gb, UKCA, CE
Added to wishlistRemoved from wishlist 0
Add to compare
Brand2B Technologies
OriginUSA
ModelModel 106L
Instrument TypePortable
Measurement Range1.5 ppbv – 100 ppmv
LOD1.5 ppbv
Response Time10 s
Zero Drift±1 ppbv (24 h)
Resolution1.5 ppbv
Accuracy±2 ppbv or ±2% of reading
Sampling Flow Rate~1 L/min
Data Storage12,288 points
Output InterfacesUSB, RS-232, 0–2.5 V analog, 4–20 mA
Power12 V DC or 120/240 V AC, 4.2 W
Dimensions9.5 × 21.0 × 21.6 cm
Weight2.1 kg
Added to wishlistRemoved from wishlist 0
Add to compare
Brand2B Technologies
OriginUSA
ModelModel 106-M
Instrument TypePortable
Measurement Range0–1000 ppm
Limit of Detection0.01 ppm
Response Time10 s
Zero Drift±1 ppbv (24 h)
Resolution1.5 ppbv
Power Consumption4.2 W
Dimensions9.5 × 21.0 × 21.6 cm
Weight2.1 kg
Sampling Flow Rate~1 L/min
Data Storage Capacity12,288 points
Output InterfacesUSB, RS-232, 0–2.5 V analog, 4–20 mA analog
Calibration TraceabilityNIST-traceable ozone standard
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0