Empowering Scientific Discovery

Beijing Huayitongtai Environmental Protection Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalox
OriginUnited Kingdom
ModelASPIDA
Instrument TypePortable
Detection TargetSingle-component (CO₂)
Measurement Range0.01–5.00% vol CO₂
Resolution0.01% vol
Accuracy±2% FS (0.01–2.5% range), ±3% FS (2.5–5.0% range)
Response Time (T90)<60 s
Zero Drift<±1% FS/6 months
Span Drift<±1% FS/6 months
Linearity Error≤1% FS
Operating Temperature–5 to +50 °C
Battery2×2100 mAh NiMH AA
Runtime>12 h per charge
Charging Time4.5 h
DisplayHigh-visibility OLED
Audible Alarm95 dB @ 30 cm (110 dB for fall detection)
Visual Indicators1 green LED (normal), 1 yellow LED (fault), 3 red LEDs (alarm)
Sensor TechnologyNon-dispersive infrared (NDIR), MIR-based
CO₂ Sensor Lifetime5 years
Optional O₂ SensorElectrochemical, 0.1–25.0% vol, T90 <30 s, lifetime 2 years
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalox
OriginUnited Kingdom
ModelSDA-CO2
Sensor Range0–5000 ppm and 0–2% CO₂
Accuracy±25 ppm or ±1% of reading (0–5000 ppm)
DisplayFull-color graphical LCD
Output Options4–20 mA, relay, Ethernet (protocol available on request)
Data LoggingOptional internal memory
AlarmConfigurable audio/visual alerts via front panel
ComplianceDNV, IMCA, Lloyd’s Register, ABS, ADCI
Sensor TypeDual-beam NDIR (Non-Dispersive Infrared)
MountingRack-mountable or panel-mountable
Replacement SensorAdvanced digital 5S3 NDIR sensor
Legacy CompatibilityDirect drop-in replacement for Analox 5001
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANALOX
OriginUnited Kingdom
ModelHYP-MO2HBYY03
Instrument TypePortable
Measurement PrincipleElectrochemical (Clark-type pO₂ sensor)
Range0–2 bar ppO₂
Accuracy±1% of reading ±1 LSD
Temperature Effect±0.2% of reading / °C
Long-term Drift≤5% of reading per year
Zero Drift<1% FS/year
Span Drift<1% FS/year
Linearity Error±1% FS
Resolution0.01 bar ppO₂
Repeatability±1% FS
Operating Temperature0–40 °C
Operating Pressure0.8–60 bar absolute (≈600 msw / 2000 fsw)
Compression/Decompression Rate Limit<2 bar/min
Power Supply9 V PP3 battery
Battery Life800 h continuous operation
Dimensions64 × 98 × 36 mm
Weight0.200 kg
Sensor ModuleAnalox 9100-9212-5H
Optional Probe9100-9212-2
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalox
OriginUnited Kingdom
ModelAspida O₂
Instrument TypePortable
Measurement Range0.1–25% O₂ (v/v)
Accuracy±0.0075% O₂
Resolution0.1% O₂
Repeatability±1% of reading
Zero Drift<1% O₂ per month
Span Drift<1% O₂ per month
Linearity Error±1% of full scale
Visual IndicationGreen (normal), Amber (fault), Triple Red (alarm)
Audible Alarm95 dB @ 30 cm
Emergency Alarm110 dB @ 30 cm
Vibration AlertYes
T90 Response Time<30 s
Operating Temperature−5 °C to +50 °C
IP RatingIP65
Dimensions127 mm × 44 mm × 90 mm
Weight355 g
PowerDual-mode — rechargeable Li-ion battery or two AA alkaline cells
Data LoggingTime-weighted average (TWA), STEL, peak hold
ComplianceATEX II 2G Ex ib IIC T4 Gb, IECEx Ex ib IIC T4 Gb, UKCA, CE
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0