Empowering Scientific Discovery

Beijing Junfang Lihua Science & Technology Research Institute

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Lihua
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGXH-1050E
Instrument TypeOnline Process Analyzer
Detection TargetMulti-component Gases
Minimum Range0–50 ppm
Repeatability≤1% F.S.
Resolution0.1 ppm
Response Time≤60 s
Zero Drift≤±2% F.S./24 h
Span Drift≤±2% F.S./24 h
Linearity Error≤±1% F.S.
Power SupplyAC 220 V ±10%, 50 Hz ±5%
Output Signal4–20 mA analog + RS232 digital interface
Operating Humidity≤90% RH (non-condensing)
Warm-up Time≤60 min
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelJF-3000
PriceUpon Request
Measurement RangeCO: 0–5% vol, O₂: 0–10% vol
Alarm Setpoint Range10–90% of Full Scale
Zero Drift≤ ±1% FS (after 8-hr warm-up, 48-hr continuous operation)
Sensitivity Drift≤ ±1% FS
Temperature Influence≤ 3% FS over 5–40°C
Response Time (T₉₀)≤ 2 min
Sample Flow Rate0.5 L/min
Output Relay Capacity220 V AC / 5 A
Dimensions1800 × 610 × 700 mm
Weight~180 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMSR (Msfang Li Hua)
OriginBeijing, China
ModelGXH-1051L
Instrument TypeOnline Gas Analyzer
Measured GasCO (Carbon Monoxide)
Measurement PrincipleNon-Dispersive Infrared (NDIR) Absorption
Range0–50 ppm (standard), customizable up to 0–100% vol
Repeatability≤ ±1% FS
Linearity Error≤ ±2% FS
Zero Drift≤ ±1% FS / 48 h
Span Drift≤ ±1% FS / 48 h
Response Time (T90)≤ 30 s
Resolution0.1 ppm (minimum)
Warm-up Time≤ 60 min
Operating Humidity≤ 90% RH (non-condensing)
Power SupplyAC 220 V ±10%, 50 Hz ±5%
Output Signal4–20 mA analog
Sample PumpIntegrated diaphragm pump
EnclosureRack-mountable embedded chassis
Temperature ControlInternal thermostatic stabilization
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Lihua
ModelGXH-1052E
OriginBeijing, China
Instrument TypeOnline Fixed-Mount Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Measured GasCO₂ (Single-Component)
Range0–500 ppm (standard)
Resolution0.1 ppm
Repeatability≤1% FS
Linearity Error≤±1% FS/24h
Zero Drift≤±2% FS/24h
Span Drift≤±2% FS/24h
Response Time (T₉₀)≤60 s
Power SupplyAC 220 V ±10%, 50 Hz ±5%
Output Signals4–20 mA analog + RS232 digital interface
Operating Humidity≤90% RH (non-condensing)
Warm-up Time≤60 min
Internal Sampling PumpIntegrated
DisplayBacklit LCD with touch interface
Data LoggingOnboard memory + PC software export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Physical & Chemical
OriginBeijing, China
ModelJF-3000
Instrument TypeOnline Analyzer
Detection TargetMulti-component Gases
Minimum Full-Scale Accuracy≤±1% F.S.
Repeatability≤±1% F.S.
Resolution0.1 ppm
Response Time≤30 s
Zero Drift≤±1% F.S.
Span Drift≤±1% F.S.
Linearity Error≤±1% F.S.
Sample Flow Rate0.5 L/min
Operating Ambient Temperature Range5–40 °C
Weight~180 kg
Dimensions1800 × 610 × 700 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Lihua
OriginBeijing, China
ModelGXH-1051E
Instrument TypeOnline Gas Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Target GasCarbon Monoxide (CO) only
Measurement Range0–50 ppm (standard), customizable up to 0–100% vol
Minimum Detectable Concentration0.1 ppm
Repeatability≤ ±1% FS
Linearity Error≤ ±2% FS
Zero Drift≤ ±1% FS / 24 h
Span Drift≤ ±1% FS / 24 h
Response Time (T90)≤ 60 s
Resolution0.1 ppm
Operating Humidity≤ 90% RH (non-condensing)
Power SupplyAC 220 V ±10%, 50 Hz ±5%
Output Signals4–20 mA analog + RS232 digital interface
Internal Sampling PumpIntegrated
DisplayBacklit LCD with touch control
Data LoggingOnboard memory with USB/PC software download capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Lihua
ModelGXH-1052L
OriginBeijing, China
Instrument TypeOnline Gas Analyzer
Measured GasCO₂ (single-component)
Range0–500 ppm (standard), customizable up to 0–100% vol
Resolution1 ppm
Repeatability≤ ±1% FS
Linearity Error≤ ±2% FS
Zero Drift≤ ±2% FS / 8 h
Span Drift≤ ±2% FS / 8 h
Response Time (T₉₀)≤ 60 s
Warm-up Time≤ 60 min
Operating Humidity≤ 90% RH (non-condensing)
Power SupplyAC 220 V ±10%, 50 Hz ±5%
Output Signal4–20 mA analog
Internal Sampling PumpIntegrated
Enclosure TypeRack-mountable embedded chassis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Lihua
OriginBeijing, China
ModelGXH-3051L
Instrument TypePortable
Detection TargetSingle-component CO
Measurement Range0–50 ppm
Repeatability±1% F.S.
Resolution0.1 ppm
Response Time≤15 s
Zero Drift≤±1% F.S./24 h
Span Drift≤±1% F.S./24 h
Linearity Error≤±2% F.S.
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Lihua
OriginBeijing, China
ModelGXH-3051E
Instrument TypePortable
Detection TargetSingle-component CO
Measurement Range0–50 ppm
Repeatability≤1% F.S.
Resolution0.1 ppm
Response Time≤30 s
Zero Drift≤±1% F.S.
Span Drift≤±1% F.S.
Linearity Error≤±1% F.S.
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelGXH-3051
PriceUpon Request
Measurement Range (CO₂)0–1000 ppm / 0–100% vol
Zero Drift≤ ±1% FS / 4 h
Span Drift≤ ±1% FS / 4 h
Linearity≤ ±1% FS
Repeatability≤ ±1%
Warm-up Time15 min
Weight1.5 kg
DisplayBacklit LCD with Direct Concentration Readout
Gas Flow ControlAdjustable via Integrated Flow Regulator
Calibration ModeSix-Port Manual Valve for Zero/Measurement Path Switching
PowerDual Rechargeable Battery System with Low-Voltage Alert
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunsquare
ModelGXH-3052L
Instrument TypePortable Gas Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR)
Target GasCO₂ (single-component)
Measurement Range0–1000 ppm
Resolution1 ppm
Repeatability±1% FS
Linearity Error≤±2% FS
Zero Drift≤±2% FS
Span Drift≤±2% FS
Response Time (T₉₀)≤30 s
Power SupplyDC (battery-operated)
ComplianceDesigned per GB/T 18204.2–2014, HJ 870–2017, and ISO 8573-1 for ambient and stack gas CO₂ monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJunfang Lihua
OriginBeijing, China
ModelGXH-3052E
Instrument TypePortable
Detection TargetSingle-component CO₂
Measurement Range0–1000 ppm
Repeatability≤1% F.S.
Resolution1 ppm
Response Time≤30 s
Zero Drift≤±1% F.S.
Span Drift≤±1% F.S.
Linearity Error≤±1% F.S.
Show next