| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | ATD II-26 |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temperature Range | Ambient to 400 °C, Control Accuracy: ±1 °C |
| Secondary Desorption Temperature Range | Ambient to 450 °C, Heating Rate: >4000 °C/min |
| Valve Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 300 °C |
| Cryo-Focusing Trap Temperature Range | −40 °C |
| Temperature Control Precision (Cryo Trap) | <±0.1 °C |
| Desorption Recovery Rate | >98% |
| Sample Capacity | 26 tubes |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Acrichi ATD I-26 |
| Instrument Type | Single-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 420 °C |
| Temperature Control Accuracy | ±1 °C (desorption furnace, 6-port valve, transfer line) |
| Desorption Pressure/Flow Range | 0–300 mL/min (continuously adjustable) |
| Desorption/Injection/Activation Time | 0–99 min |
| Sample Capacity | 26 positions |
| Sorbent Tube Dimensions | 6.35 mm OD × 88.9 mm L (1/4″ × 3.5″) |
| Power Consumption | 500 W |
| Dimensions (W×D×H) | 605 × 350 × 520 mm |
| Weight | ~30 kg |
| Desorption Recovery Efficiency | >98% |
| Flow Display | Digital electronic mass flow indication |
| Control Interface | Integrated 7-inch capacitive touchscreen |
| Method Storage | Up to 10 user-editable and recallable methods |
| Automation | Fully automated unattended operation with GC and data system synchronization |
| Leak Detection | Built-in automatic leak check routine |
| Fault Monitoring | Real-time thermal and pneumatic fault diagnostics |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | ATD II-26D |
| Instrument Type | Secondary Thermal Desorber |
| Desorption Temperature Range | Ambient to 450 °C, Heating Rate >3600 °C/min |
| Cold Trap Temperature Range | −40 °C to Ambient (Electronic Cooling) |
| Desorption Recovery Rate | >98% |
| Sample Capacity | 52 Positions (26 × 2 Dual Channels) |
| Valve & Transfer Line Temp Control | Ambient to 220 °C (±1 °C) |
| Focusing Tube Temp Control | Ambient to 450 °C, Heating Rate >3000 °C/min |
| Carrier Gas Flow Control | 0–100 mL/min (Backflush), 100 mL/min (Sample Preparation) |
| Timing Resolution | 0.1 min (0.0–999.9 min) |
| Adsorbent Tube Dimensions | 6.35 mm OD × 88.9 mm L (¼″ × 3.5″) |
| Power | 900 W, 220 V, 50 Hz |
| Dimensions | 810 × 450 × 510 mm |
| Weight | ~40 kg |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Acrichi ATD I-50 |
| Instrument Type | Single-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 420 °C |
| Temperature Control Accuracy | ±1 °C (desorption furnace, 6-port valve, transfer line) |
| Desorption Pressure/Flow Range | 0–300 mL/min (continuously adjustable) |
| Desorption/Injection/Activation Time | 0–99 min |
| Sample Capacity | 50 positions |
| Sorbent Tube Dimensions | 6.35 mm OD × 88.9 mm L (1/4″ × 3.5″) |
| Power Consumption | 500 W |
| Dimensions (W×D×H) | 605 × 350 × 520 mm |
| Weight | ~30 kg |
| Desorption Recovery Rate | >98% |
| Interface | Touchscreen HMI with event-triggered GC synchronization |
| Method Storage | 10 user-editable, recallable methods |
| Leak Detection | Integrated real-time pressure decay monitoring |
| Fault Diagnostics | Auto-alert with on-screen status code and operational log |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | ATD I-26D |
| Desorption Temperature Range | Ambient to 420 °C |
| Temperature Control Accuracy | ±1 °C (desorption furnace, six-port valve, transfer line) |
| Desorption Flow Rate | 0–300 mL/min, continuously adjustable |
| Desorption/Injection/Activation Time | 0–99 min |
| Sample Capacity | 52 positions (26 × 2 dual-channel configuration) |
| Trap Tube Dimensions | 6.35 mm OD × 88.9 mm L (1/4″ × 3.5″) |
| Power Consumption | 600 W |
| Dimensions (W×D×H) | 810 × 450 × 510 mm |
| Weight | ~35 kg |
| Desorption Recovery Rate | >98% |
| Valve Type | Heated six-port rotary valve |
| Interface | Touchscreen HMI, event-triggered GC start, 10 programmable methods |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Acrichi ATD II-50 |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Temperature Range | Ambient to 450 °C |
| Heating Rate | >6000 °C/min |
| Six-Port Valve Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 220 °C |
| Cold Trap Temperature Range | −40 °C to Ambient (Electronic Cooling) |
| Temperature Control Accuracy | ±1 °C |
| Desorption Recovery Rate | >98% |
| Sample Capacity | 50 positions |