Empowering Scientific Discovery

Beijing Kanggao Te Instrument & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMegger
OriginUSA
ModelMOM600A
Voltage Options115 V AC / 230 V AC
Output Current Range0–600 A DC
Resistance Measurement Range0–1999 µΩ
Resolution1 µΩ
Accuracy±1% of reading + 1 digit (at 100–600 A)
Operating Temperature (115 V)0°C to +50°C
Operating Temperature (230 V)0°C to +40°C
Storage Temperature−40°C to +70°C
Humidity5–95% RH, non-condensing
Dimensions (Instrument)356 × 203 × 241 mm
Weight (115 V unit)25 kg
Weight (230 V unit)24.7 kg
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Megger
ModelMIT525
Test Voltage Range50 V to 5 kV (adjustable in 10 V steps up to 1 kV, 25 V steps above)
Maximum Insulation Resistance Measurement10 TΩ
Short-Circuit Current3 mA
DisplayBacklit LCD with multi-parameter real-time readout (resistance, voltage, leakage current, capacitance, time constant, battery status, elapsed test time)
BatteryRechargeable Li-ion, 6 h continuous operation, 2.5 h full charge
Ingress ProtectionIP65
Safety RatingCAT IV 600 V (up to 3000 m altitude)
ComplianceIEC 61010-1, IEC 61557-2
Software CompatibilityPowerDB™ analysis software (via USB/RS232)
Real-Time Clock & Temperature LoggingYes
Diagnostic Test ModesIR, IR(t), PI, DAR, DD, SV (Step Voltage), Ramp Test
Input Protection3 mA noise immunity, ±2% accuracy at 100 MΩ load (500 kΩ leakage protected)
Dual-Shell HousingOuter impact-resistant shell + inner flame-retardant shell
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMegger
ModelMIT525
Test Voltage Range250 V to 5 kV (5 preset + user-defined)
Max Resistance Measurement10 TΩ
Short-Circuit Current3 mA
Accuracy±5% up to 1 TΩ, ±20% up to 10 TΩ
DisplayBacklit LCD with dual-parameter readout
Battery11.1 V Li-ion, 5.2 Ah, ~6 h continuous operation at 5 kV
ChargingAC mains operation during test
Safety RatingCAT IV 600 V, double insulation, IP65 (lid closed)
ComplianceIEC 61010-1, IEC 61326-1, IEC 61010-31:2008 (test leads)
Dimensions315 × 285 × 181 mm
Weight4.5 kg
Data InterfaceIsolated USB-B (device mode), compatible with Megger PowerDB Lite
Diagnostic ModesPI, DAR, DD, SV, Ramp Test
Voltage Meter Function30–660 V ac/dc, ±3% ±3 V
Noise RejectionUp to 3 mA interference suppression
Altitude OperationRated CAT IV 600 V up to 3000 m
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMegger
ModelMIT525
Test Voltage Range50 V to 5 kV (5 preset + user-defined)
Maximum Resistance Measurement10 TΩ
Accuracy±5% up to 1 TΩ at 5 kV
Short-Circuit Current3 mA
Safety RatingCAT IV 600 V, Double Insulation
Ingress ProtectionIP65 (enclosure)
Operating AltitudeUp to 3000 m
BatteryRechargeable Li-ion, 6 h continuous operation at 5 kV
Charging Time1.5 h (full charge)
DisplayBacklit LCD with multi-parameter readout
Data StorageInternal memory with time/date stamping
InterfaceIsolated USB-B port for PowerDB software integration
ComplianceIEC 61010-1, IEC 61010-2-033, IEC 61010-31:2008, IEEE 43, ASTM D257, BS EN 60204-1
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0