Empowering Scientific Discovery

Beijing Liyangtech Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPM
OriginGermany
ModelMT 1000
Product TypeOnline Dew Point / Trace Moisture Analyzer
Measurement PrinciplePhosphorus Pentoxide (P₂O₅) Electrolytic Method
Operating Temperature-20 °C to +50 °C
Accuracy±0.4 ppm or ±5% of reading
Range0–2000 ppm H₂O
Resolution0.1 ppm
DisplayColor touchscreen with independent keypad control
Analog Output4–20 mA (field-scalable)
Alarm OutputRelay (NO/NC), fully configurable across full scale
Power Supply220 VAC, 50 Hz, 1×1.0 A fuse
Enclosure OptionsWall-mount, benchtop, rack-mount, portable (mains-powered only)
Dimensions320 × 240 × 230 mm (W×H×D)
Weight~5 kg
Sensor Cell MaterialPVDF and stainless steel
Electrode MaterialPlatinum
Sample Flow Rate20 NL/h or 100 NL/h (user-selectable)
Sample Pressure (at sensor)≤200 mbar
Sample Temperature+5 °C to +65 °C
Response Time<1 s
Gas Fitting6 mm compression fitting
Probe CableStandard 1.4 m (extendable up to 150 m)
Electrical ConnectorBinder type
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCMC (Schimse)
OriginGermany
ModelTMA-202-W-Ex
Product TypeIn-line Dew Point Analyzer
PrinciplePhosphorus Pentoxide (P₂O₅) Electrolytic Method
Operating Temperature−10 °C to +50 °C
Accuracy±1% of full scale
Repeatability±0.1% of full scale
Measurement Ranges0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–2500 ppm (auto/manual switching)
Response Time (T₉₀)<1 s
T₅₀ Response<8 s
Sample Flow Rate20 NL/h
Recommended Sample Pressure0.1–0.5 barg
Sample Temperature5–50 °C
Environmental Temperature Range5–65 °C
DisplayTouchscreen with optional Chinese language interface
Analog Output0/4–20 mA (configurable)
Alarm Outputs2 relay outputs
Intrinsic SafetyIntegrated Zener barrier (Ex ia IIC T4 Ga)
EnclosureIP65
Dimensions300 mm (W) × 260 mm (H) × 280 mm (D)
Standard Cable Length3 m (up to 300 m optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCMC
OriginGermany
ModelOilQSens
Conductivity Range0.1–20,000 pS/m (Transformer Grade: 0.1–50 pS/m)
Dielectric Constant Range1.0–5.0
Temperature Range−10 °C to +70 °C
Sensitivity0.01 pS/m (conductivity), 1×10⁻⁶ (dielectric constant)
Accuracy±1% of reading ±0.5 pS/m (conductivity), ±1% ±0.0001 (dielectric constant)
Response Time<45 s
Max Process Pressure60 barg @ 20 °C
Sensor MaterialStainless steel flow cell & fittings, aluminum sensor head
Communication InterfacesRS232, LAN, WLAN, RS485, Profibus, Modbus, GSM (optional)
Power Supply90–264 VAC / 50–60 Hz or 24 VDC (optional)
Dimensions & WeightSensor: Ø70 × H103 mm, 2.70 kg
Communication Module87 × 110 × 30 mm, 0.25 kg
Control Unit210 × 250 × 165 mm, 4.45 kg
SoftwareWSens (optional)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0